Digital Slot-Scan Charge-coupled Device Radiography versus AMBER and Bucky Screen-Film Radiography for Detection of Simulated Nodules and Interstitial Disease in a Chest Phantom
Authors:
- Lucia J. M. KroftLKLucia J. M. Kroft
- Jacob GeleijnsJGJacob Geleijns
- Bart J. A. MertensBMBart J. A. Mertens
- Wouter J. H. VeldkampWVWouter J. H. Veldkamp
- Harmine M. ZonderlandHZHarmine M. Zonderland
- Albert de RoosARAlbert de Roos
- 1 April 2004
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 231 (1) , 156-163
Abstract
To evaluate the diagnostic performance of full-field slot-scan charge-coupled device (CCD)-based digital radiography in the detection of simulated chest diseases in clinical conditions versus that of two screen-film techniques: advanced multiple beam equalization radiography (AMBER) and Bucky radiography. Simulated nodules and interstitial nodular and interstitial linear lesions were attached onto an anthropomorphic chest phantom. One hundred sixty-eight lesions were distributed over 25 configurations. A posteroanterior chest radiograph of each configuration was obtained with each technique. The images were presented to six observers. Each lesion was assigned one of two outcome scores: "detected" or "not detected." False-positive readings were evaluated. Differences between the imaging methods were analyzed by using a semiparametric logistic regression model. For simulated nodules and interstitial linear disease, no statistically significant difference was found in diagnostic performance between CCD digital radiography and AMBER. The detection of simulated interstitial nodular disease was better with CCD digital radiography than with AMBER: Sensitivity was 71% (77 of 108 interstitial nodular lesions) with CCD digital radiography but was 56% (60 of 108 lesions) with AMBER (P =.041). Better results for the detection of all lesion types in the mediastinum were observed with CCD digital radiography than with Bucky screen-film radiography: Sensitivity was 45% (227 of 504 total simulated lesions) with CCD digital radiography but was 24% (119 of 504 lesions) with Bucky radiography (P <.001). There were fewer false-positive observations with CCD digital radiography (35 [5.7%] of 609 observations) than with Bucky radiography (47 [9.5%] of 497 observations; P =.012). Differences were in favor of the full-field slot-scan CCD digital radiographic technique. This technique provides a digital alternative to AMBER and Bucky screen-film radiography.Keywords
This publication has 19 references indexed in Scilit:
- Evaluation of the imaging properties of two generations of a CCD‐based system for digital chest radiographyMedical Physics, 2002
- Image quality vs radiation dose for a flat-panel amorphous silicon detector: a phantom studyEuropean Radiology, 2001
- Imaging Characteristics of an Amorphous Silicon Flat-Panel Detector for Digital Chest RadiographyRadiology, 2001
- New multilinear solid state detector for digital slot scan radiography1999
- Principles of Digital Radiography with Large-Area, Electronically Readable Detectors: A Review of the BasicsRadiology, 1999
- Organ Dose Calculation in Medical X Ray Examinations by the Program PCXMCRadiation Protection Dosimetry, 1998
- Contrast-detail detectability analysis: Comparison of a digital spot mammography system and an analog screen-film mammography systemAcademic Radiology, 1997
- System considerations in CCD‐based x‐ray imaging for digital chest radiography and digital mammographyMedical Physics, 1997
- X-ray detectors for digital radiographyPhysics in Medicine & Biology, 1997
- AMBER: a scanning multiple-beam equalization system for chest radiography.Radiology, 1988