Nonisolated Three-Phase Current DC-Link Buck–Boost EV Charger With Virtual Output Midpoint Grounding and Ground Current Control
- 5 June 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (1) , 1398-1413
Abstract
Non-isolated three-phase AC/DC converter concepts facilitate more compact and more efficient realizations of future EV chargers. However, without the galvanic isolation and/or high common-mode (CM) impedance provided by an isolation transformer, non-isolated chargers must employ other means to suppress CM leakage currents to ground sufficiently and to prevent nuisance tripping of mandatory residual current devices (RCDs). Typically, the required EMI filters reduce high-frequency (HF) CM leakage currents to uncritical values. However, low-frequency CM voltages, e.g., generated by third-harmonic injection, may drive significant LF CM currents through the parasitic capacitances of the DC output (including the battery pack) to protective earth (PE). Therefore, considering a non-isolated three-phase buck-boost current DC-link PFC rectifier system that consists of a buck-type current-source rectifier (CSR) stage and a three-level boost-type DC/DC-stage, this paper first proposes a virtual grounding control (VGC) of the DC output voltage midpoint. VGC employs the DC/DC-stage to compensate the LF (third-harmonic) CM voltage inherently generated by the CSR-stage, and thus controls the LF CM voltage between the DC output midpoint and PE to zero. This enables further a direct connection of the DC output midpoint to PE, where an additionally proposed ground current control (GCC) ensures near-zero LF CM leakage current. The proposed concepts are verified with a 10kW hardware demonstrator (power density of 6.4 kW/dm3 or 107.5 W/in3, full-load peak efficiency of 98.5%) considering TT (Terra-Terra) and TN (Terra-Neutral) grounding systems. With a direct connection of the DC output midpoint to PE, GCC limits the LF CM leakage current to < 6mA RMS, i.e., significantly below typical RCD trip levels, and, using the human-body impedance model according to UL 2202, achieves a test voltage of 110mV that is clearly below the most stringent limit (250 mV) of the standard.Keywords
This publication has 33 references indexed in Scilit:
- Advanced Synergetic Charge Control of Three-Phase PFC Buck-Boost Current DC-Link EV Chargers2022
- Synergetic Control of Three-Phase AC-AC Current-Source Converter Employing Monolithic Bidirectional 600 V GaN Transistors2021
- Common-Mode-Free Bidirectional Three-Phase PFC-Rectifier for Non-Isolated EV Charger2021
- Comparison of Unidirectional Three- and Four-Wire-Based Boost PFC-Rectifier Topologies for Non-Isolated Three-Phase EV On-Board Chargers Under Common-Mode Aspects2021
- Investigation of Fourth-leg for Common-mode Noise Reduction in Three-level Neutral Point Clamped Inverter Fed Motor Drive2019
- Ground current control scheme for back‐to‐back three‐phase T‐type rectifier and inverter systemsIEEJ Transactions on Electrical and Electronic Engineering, 2018
- Unified space vector PWM control for current source inverter2012
- A new concept for minimizing high-frequency common-mode EMI of three-phase PWM rectifier systems keeping high utilization of the output voltage2002
- Elimination of common-mode voltage in three-phase sinusoidal power convertersIEEE Transactions on Power Electronics, 1999
- An improved inverter output filter configuration reduces common and differential modes dv/dt at the motor terminals in PWM drive systemsIEEE Transactions on Power Electronics, 1998