Daifei Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daifei Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Johann Walter Kolar
Power Electronic Systems Laboratory (PES), ETH Zrich, Zrich, Switzerland
11 shared publications - Jonas Huber
Power Electronic Systems Laboratory (PES), ETH Zrich, Zrich, Switzerland
11 shared publications Danqing Cao
Power Electronic Systems Laboratory, ETH Zrich, Zrich, Switzerland
2 shared publications- Jordi Everts
Prodrive Technologies Innovation Services B.V, EL Son, The Netherlands
2 shared publications - Neha Nain
Power Electronic Systems Laboratory, ETH Zurich, Zurich, Zurich, Switzerland
2 shared publications - Bhargav Pandya
School of Chemical Engineering, University of Birmingham, Birmingham B15 2TT, UK
1 shared publication
Latest Publications
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 38-42
A New GaN T-Type Three-Switch Bridge-Leg for Cryogenic HTS Magnet Power Supplies
Cryogenic step-down dc–dc converters for supplying high-temperature superconducting magnets operate from low dc input voltages in the order of 1 V and provide high output/magnet currents. The proposed three-switch T-type (3STT) bridge-leg utilizes the (limited) reverse-blocking capability of standard gallium nitride (GaN) transistors to provide the same functionality (bipolar output voltage) as a conventional full-bridge (FB) topology. Advantageously, the 3STT features only a single transistor in the load current path (instead of two for the FB), reducing conduction losses by at least 50%. Loss measurements of a 25 A 3STT phase module demonstrator operating at 77 K (immersed in liquid nitrogen) verify the concept.
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 38-42
A New GaN T-Type Three-Switch Bridge-Leg for Cryogenic HTS Magnet Power Supplies
Cryogenic step-down dc–dc converters for supplying high-temperature superconducting magnets operate from low dc input voltages in the order of 1 V and provide high output/magnet currents. The proposed three-switch T-type (3STT) bridge-leg utilizes the (limited) reverse-blocking capability of standard gallium nitride (GaN) transistors to provide the same functionality (bipolar output voltage) as a conventional full-bridge (FB) topology. Advantageously, the 3STT features only a single transistor in the load current path (instead of two for the FB), reducing conduction losses by at least 50%. Loss measurements of a 25 A 3STT phase module demonstrator operating at 77 K (immersed in liquid nitrogen) verify the concept.
- 6 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 9167-9186
Synergetic Control of a Monolithic-Bidirectional-GaN-Transistor-Based Three-Phase Current DC-Link AC–AC Converter
Variable speed drives (VSDs) operating from a threephase mains are typically realized as ac–ac voltage dc-link/source converters (VSCs). Compact VSCs using wide-bandgap (WBG) semiconductors often require LC output filters to protect the motor from high dv/dt of the switched voltage. Ac-ac current dc-link/source converters (CSCs) featuring a back-to-back connection of a current-source rectifier (CSR) and current-source inverter (CSI) by a shared dc-link inductor inherently provide continuous motor voltages. This paper introduces the loss-optimal operating mode of ac–ac CSCs: using the minimum possible and hence time-varying dc-link current (the maximum absolute value of the CSR and CSI phase currents) minimizes the conduction losses and either the CSR or the CSI operates with 2/3-PWM (one phase terminal clamped to the dc-link inductor while only the remaining two phase currents are synthesized with PWM), reducing switching losses. The respective other stage employs PWM in all three phases (3/3-PWM) and shapes the dc-link current. A proposed synergetic control method realizes loss-optimal operation for the entire output voltage and current range of the ac-ac CSC, with motor voltages lower and higher than the grid voltage, and ensures smooth transitions between operating points. Experimental results of a 1.4 kW, 200 V (line-to-line rms) ac–ac CSC demonstrator using first-generation 600 V, 140${\mathrm{m}}\mathrm{\Omega }$ monolithic bidirectional GaN transistors, grid-side and motor-side EMI filters, and a switching frequency of 72 kHz confirm the loss optimal operation (measured nominal ac-ac efficiency increases by 0.3% to 97% compared to conventional operation; part-load efficiency gains of up to 1% are observed) and seamless transitions between operating points.
- 6 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 9167-9186
Synergetic Control of a Monolithic-Bidirectional-GaN-Transistor-Based Three-Phase Current DC-Link AC–AC Converter
Variable speed drives (VSDs) operating from a threephase mains are typically realized as ac–ac voltage dc-link/source converters (VSCs). Compact VSCs using wide-bandgap (WBG) semiconductors often require LC output filters to protect the motor from high dv/dt of the switched voltage. Ac-ac current dc-link/source converters (CSCs) featuring a back-to-back connection of a current-source rectifier (CSR) and current-source inverter (CSI) by a shared dc-link inductor inherently provide continuous motor voltages. This paper introduces the loss-optimal operating mode of ac–ac CSCs: using the minimum possible and hence time-varying dc-link current (the maximum absolute value of the CSR and CSI phase currents) minimizes the conduction losses and either the CSR or the CSI operates with 2/3-PWM (one phase terminal clamped to the dc-link inductor while only the remaining two phase currents are synthesized with PWM), reducing switching losses. The respective other stage employs PWM in all three phases (3/3-PWM) and shapes the dc-link current. A proposed synergetic control method realizes loss-optimal operation for the entire output voltage and current range of the ac-ac CSC, with motor voltages lower and higher than the grid voltage, and ensures smooth transitions between operating points. Experimental results of a 1.4 kW, 200 V (line-to-line rms) ac–ac CSC demonstrator using first-generation 600 V, 140${\mathrm{m}}\mathrm{\Omega }$ monolithic bidirectional GaN transistors, grid-side and motor-side EMI filters, and a switching frequency of 72 kHz confirm the loss optimal operation (measured nominal ac-ac efficiency increases by 0.3% to 97% compared to conventional operation; part-load efficiency gains of up to 1% are observed) and seamless transitions between operating points.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (11) , 14691-14707
Analytical Modeling and Comparison of EMI pre-filter Noise Emissions of Three-Phase Voltage and Current DC-Link Converters
Three-phase power-factor-correction rectifiers (PFC) or motor drive inverters can be realized using two dual converter topologies featuring either a voltage dc-link (voltage source) or a current dc-link (current source). This article presents a generic comparison of the pre-filter differential-mode (DM) and common-mode (CM) electromagnetic interference (EMI) noise emissions of these two topologies (considering only the switching stage), which serve as indicators for the required EMI filter attenuation and, hence, EMI filter realization effort. In contrast to the voltage dc-link topology, the DM pre-filter noise of the current dc-link topology is primarily attributed to the current pulses generated by its switching stage, resulting in high-frequency voltage drops across the 50- $\Omega$ measurement resistor employed in line-impedance stabilization networks (LISNs) as defined by, e.g., the CISPR 11 standard. Addressing this aspect, low-complexity analytical expressions for approximating the envelopes of the pre-filter DM and CM noise amplitude spectra are derived and experimentally verified using 400 V (line-to-line rms), 10 kW voltage and current dc-link ac/dc converter demonstrator systems. The DM pre-filter noise of current dc-link converters is lower than that of the voltage dc-link converters if the equivalent ac resistance the converter represents to the mains is higher than the LISN's 50- $\Omega$ measurement resistor. On the other hand, the current dc-link converter's CM pre-filter noise is, in typical cases, lower than the voltage dc-link converter's; current dc-link converters are thus an interesting choice for motor drive inverter applications.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (11) , 14691-14707
Analytical Modeling and Comparison of EMI pre-filter Noise Emissions of Three-Phase Voltage and Current DC-Link Converters
Three-phase power-factor-correction rectifiers (PFC) or motor drive inverters can be realized using two dual converter topologies featuring either a voltage dc-link (voltage source) or a current dc-link (current source). This article presents a generic comparison of the pre-filter differential-mode (DM) and common-mode (CM) electromagnetic interference (EMI) noise emissions of these two topologies (considering only the switching stage), which serve as indicators for the required EMI filter attenuation and, hence, EMI filter realization effort. In contrast to the voltage dc-link topology, the DM pre-filter noise of the current dc-link topology is primarily attributed to the current pulses generated by its switching stage, resulting in high-frequency voltage drops across the 50- $\Omega$ measurement resistor employed in line-impedance stabilization networks (LISNs) as defined by, e.g., the CISPR 11 standard. Addressing this aspect, low-complexity analytical expressions for approximating the envelopes of the pre-filter DM and CM noise amplitude spectra are derived and experimentally verified using 400 V (line-to-line rms), 10 kW voltage and current dc-link ac/dc converter demonstrator systems. The DM pre-filter noise of current dc-link converters is lower than that of the voltage dc-link converters if the equivalent ac resistance the converter represents to the mains is higher than the LISN's 50- $\Omega$ measurement resistor. On the other hand, the current dc-link converter's CM pre-filter noise is, in typical cases, lower than the voltage dc-link converter's; current dc-link converters are thus an interesting choice for motor drive inverter applications.
- 30 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 1541-1554
Nonisolated Bidirectional Three-Phase Three-Level Wide-Output-Voltage-Range Voltage DC-Link EV Charger
Non-isolated three-phase AC/DC EV chargers show improved efficiency and power density compared to their counterparts with a galvanic isolation stage, but residual current devices (RCDs) are mandatory to ensure electrical safety. However, RCDs are prone to nuisance tripping caused by low-frequency (LF) common-mode (CM) leakage currents through the ground, which therefore must be suppressed. Therefore, first, modulation schemes that do not result in LF CM voltages (i.e., do not employ third harmonic voltage injection) that could drive LF CM currents through parasitic capacitors from the DC output to ground must be employed. Second, closed-loop ground current control (GCC) ensures near-zero LF CM leakage currents even with a direct connection of the charger DC output midpoint to protective earth (PE). Considering a voltage DC-link PFC rectifier system that consists of a boost-type three-level T-type (Vienna) AC/DC-stage and a DC/DC-stage with two stacked buck converters, this paper proposes a new modulation scheme for buck-mode operation at low DC output voltages: the DC/DC-stage then shapes the DC-link voltage such that only one of the AC/DC-stage’s three bridge-legs operates with high-frequency switching (1/3-PWM) at any given time, and, different from previous methods, does not require third-harmonic injection to do so. Further, a synergetic GCC is proposed, which operates the two converter stages in the loss-optimum mode for any output DC voltage (buck-mode and boost-mode) and regulates the LF CM ground current to near zero. The proposed concepts are verified using a 10kW hardware demonstrator with a wide output voltage range (200V to 800 V) and a direct connection of the DC output midpoint to PE, considering TT (Terra-Terra) and TN (Terra-Neutral) grid grounding systems, whereby the proposed GCC results in LF CM leakage currents below 7 mA, i.e., far below typical RCD trip limits (30 mA). The test voltages obtained with the human-body impedance model from UL 2202 are below 120mV, i.e., below 50% of even the most stringent limit of 250mV of the standard.
- 30 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 1541-1554
Nonisolated Bidirectional Three-Phase Three-Level Wide-Output-Voltage-Range Voltage DC-Link EV Charger
Non-isolated three-phase AC/DC EV chargers show improved efficiency and power density compared to their counterparts with a galvanic isolation stage, but residual current devices (RCDs) are mandatory to ensure electrical safety. However, RCDs are prone to nuisance tripping caused by low-frequency (LF) common-mode (CM) leakage currents through the ground, which therefore must be suppressed. Therefore, first, modulation schemes that do not result in LF CM voltages (i.e., do not employ third harmonic voltage injection) that could drive LF CM currents through parasitic capacitors from the DC output to ground must be employed. Second, closed-loop ground current control (GCC) ensures near-zero LF CM leakage currents even with a direct connection of the charger DC output midpoint to protective earth (PE). Considering a voltage DC-link PFC rectifier system that consists of a boost-type three-level T-type (Vienna) AC/DC-stage and a DC/DC-stage with two stacked buck converters, this paper proposes a new modulation scheme for buck-mode operation at low DC output voltages: the DC/DC-stage then shapes the DC-link voltage such that only one of the AC/DC-stage’s three bridge-legs operates with high-frequency switching (1/3-PWM) at any given time, and, different from previous methods, does not require third-harmonic injection to do so. Further, a synergetic GCC is proposed, which operates the two converter stages in the loss-optimum mode for any output DC voltage (buck-mode and boost-mode) and regulates the LF CM ground current to near zero. The proposed concepts are verified using a 10kW hardware demonstrator with a wide output voltage range (200V to 800 V) and a direct connection of the DC output midpoint to PE, considering TT (Terra-Terra) and TN (Terra-Neutral) grid grounding systems, whereby the proposed GCC results in LF CM leakage currents below 7 mA, i.e., far below typical RCD trip limits (30 mA). The test voltages obtained with the human-body impedance model from UL 2202 are below 120mV, i.e., below 50% of even the most stringent limit of 250mV of the standard.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (1) , 28-42
Optimal Synergetic Control of Three-Phase/Level Boost–Buck Voltage DC-Link AC/DC Converter for Very-Wide Output Voltage Range High-Efficiency EV Charger
Universal high-power three-phase mains interfaces for electric vehicle (EV) charging must provide a wide output voltage range (e.g., 200V to 800 V) and thus provide buck and boost capability. An advantageous realization combining a three-level (3-L) T-type (Vienna) boost-type PFC voltage-source rectifier (VSR) with a 3-L buck-type DC/DC converter stage is presented in this paper. For high output voltages (boost-mode), the VSR-stage operates with 3/3-PWM, i.e., continuous PWM of all three phases to regulate the output voltage while the DC/DC-stage remains clamped to avoid switching losses. For low output voltages (buck-mode), the DC/DC-stage advantageously controls the DC-link voltage according to a time-varying reference value, which allows to sinusoidally shape the currents of two mains phases, such that the VSR-stage can operate with 1/3-PWM (only one of the three bridge-legs operates with PWM at any given time) with reduced switching losses. This paper proposes a novel 2/3-PWM scheme for the output voltage transition region, where output voltages are between the buck-mode and the boost-mode. This enables loss-optimum operation (i.e., the minimum number of the VSR-stage bridge-legs operating with PWM, and with the minimum possible DC-link voltage) for any output voltage. Furthermore, this paper introduces a new synergetic control concept that ensures seamless transitions between the loss-optimum operating modes. A comprehensive experimental verification, including pre-compliance EMI measurements, using a 10-kW hardware demonstrator with a power density of 5.4 kW/dm 3 (91 W/in 3 ), a peak efficiency of 98.8% at rated power and 560V output voltage, and >98% efficiency for all operating points with >400V output voltage and more than about 50% of rated power, confirms the theoretical analyses.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (1) , 28-42
Optimal Synergetic Control of Three-Phase/Level Boost–Buck Voltage DC-Link AC/DC Converter for Very-Wide Output Voltage Range High-Efficiency EV Charger
Universal high-power three-phase mains interfaces for electric vehicle (EV) charging must provide a wide output voltage range (e.g., 200V to 800 V) and thus provide buck and boost capability. An advantageous realization combining a three-level (3-L) T-type (Vienna) boost-type PFC voltage-source rectifier (VSR) with a 3-L buck-type DC/DC converter stage is presented in this paper. For high output voltages (boost-mode), the VSR-stage operates with 3/3-PWM, i.e., continuous PWM of all three phases to regulate the output voltage while the DC/DC-stage remains clamped to avoid switching losses. For low output voltages (buck-mode), the DC/DC-stage advantageously controls the DC-link voltage according to a time-varying reference value, which allows to sinusoidally shape the currents of two mains phases, such that the VSR-stage can operate with 1/3-PWM (only one of the three bridge-legs operates with PWM at any given time) with reduced switching losses. This paper proposes a novel 2/3-PWM scheme for the output voltage transition region, where output voltages are between the buck-mode and the boost-mode. This enables loss-optimum operation (i.e., the minimum number of the VSR-stage bridge-legs operating with PWM, and with the minimum possible DC-link voltage) for any output voltage. Furthermore, this paper introduces a new synergetic control concept that ensures seamless transitions between the loss-optimum operating modes. A comprehensive experimental verification, including pre-compliance EMI measurements, using a 10-kW hardware demonstrator with a power density of 5.4 kW/dm 3 (91 W/in 3 ), a peak efficiency of 98.8% at rated power and 560V output voltage, and >98% efficiency for all operating points with >400V output voltage and more than about 50% of rated power, confirms the theoretical analyses.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (12) , 15184-15198
A Three-Phase Synergetically Controlled Buck–Boost Current DC-Link EV Charger
With the ever-increasing share of electric vehicles (EVs) comes a need for highly efficient and compact EV chargers. EV charger modules should provide a wide-output-voltage range (200–1000 V) to ensure compatibility with various EV battery voltages. Thus, buck–boost functionality is needed, which can advantageously be realized by a current DC-link topology; a buck-type current-source rectifier (CSR)-stage and a downstream three-level boost-type DC/DC-stage share the main magnetic component (the DC-link inductor). Furthermore, the two stages can operate collaboratively; for low output voltages, the CSR-stage controls the output voltage and the DC/DC-stage is clamped to avoid switching losses; for high output voltages, the DC/DC-stage shapes the DC-link current such that the CSR-stage operates with 2/3-PWM (switching limited to two out of the three phases) and, hence, with reduced switching losses. This article, thus, introduces a simplified synergetic control concept that ensures this loss-optimum operation of the two-stage system for any output voltage. A compact 10-kW hardware demonstrator with a power density of 6.4 kW/dm 3 (107.5 W/in 3 ) is then used to verify the control concept and the seamless transitions between operating modes. For the first time, a system-level experimental demonstration of the loss savings achieved by 2/3-PWM is provided, and the precompliance conducted EMI test results meet CISPR 11 Class A. Moreover, a detailed experimental characterization of losses/efficiency over the full range of output voltage and power confirms the loss models and the design procedure presented earlier. Finally, the demonstrator shows quite a flat efficiency characteristic (higher than 98% for most operating points with output voltages above $400 \,\mathrm{V}$ and more than 25% of rated load) with a peak efficiency of 98.8% at 520 V output voltage and 5 kW. All in all, the presented current DC-link buck–boost PFC rectifier system features a promising solution for future isolated or nonisolated EV charger modules.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (12) , 15184-15198
A Three-Phase Synergetically Controlled Buck–Boost Current DC-Link EV Charger
With the ever-increasing share of electric vehicles (EVs) comes a need for highly efficient and compact EV chargers. EV charger modules should provide a wide-output-voltage range (200–1000 V) to ensure compatibility with various EV battery voltages. Thus, buck–boost functionality is needed, which can advantageously be realized by a current DC-link topology; a buck-type current-source rectifier (CSR)-stage and a downstream three-level boost-type DC/DC-stage share the main magnetic component (the DC-link inductor). Furthermore, the two stages can operate collaboratively; for low output voltages, the CSR-stage controls the output voltage and the DC/DC-stage is clamped to avoid switching losses; for high output voltages, the DC/DC-stage shapes the DC-link current such that the CSR-stage operates with 2/3-PWM (switching limited to two out of the three phases) and, hence, with reduced switching losses. This article, thus, introduces a simplified synergetic control concept that ensures this loss-optimum operation of the two-stage system for any output voltage. A compact 10-kW hardware demonstrator with a power density of 6.4 kW/dm 3 (107.5 W/in 3 ) is then used to verify the control concept and the seamless transitions between operating modes. For the first time, a system-level experimental demonstration of the loss savings achieved by 2/3-PWM is provided, and the precompliance conducted EMI test results meet CISPR 11 Class A. Moreover, a detailed experimental characterization of losses/efficiency over the full range of output voltage and power confirms the loss models and the design procedure presented earlier. Finally, the demonstrator shows quite a flat efficiency characteristic (higher than 98% for most operating points with output voltages above $400 \,\mathrm{V}$ and more than 25% of rated load) with a peak efficiency of 98.8% at 520 V output voltage and 5 kW. All in all, the presented current DC-link buck–boost PFC rectifier system features a promising solution for future isolated or nonisolated EV charger modules.
- 5 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (1) , 1398-1413
Nonisolated Three-Phase Current DC-Link Buck–Boost EV Charger With Virtual Output Midpoint Grounding and Ground Current Control
Non-isolated three-phase AC/DC converter concepts facilitate more compact and more efficient realizations of future EV chargers. However, without the galvanic isolation and/or high common-mode (CM) impedance provided by an isolation transformer, non-isolated chargers must employ other means to suppress CM leakage currents to ground sufficiently and to prevent nuisance tripping of mandatory residual current devices (RCDs). Typically, the required EMI filters reduce high-frequency (HF) CM leakage currents to uncritical values. However, low-frequency CM voltages, e.g., generated by third-harmonic injection, may drive significant LF CM currents through the parasitic capacitances of the DC output (including the battery pack) to protective earth (PE). Therefore, considering a non-isolated three-phase buck-boost current DC-link PFC rectifier system that consists of a buck-type current-source rectifier (CSR) stage and a three-level boost-type DC/DC-stage, this paper first proposes a virtual grounding control (VGC) of the DC output voltage midpoint. VGC employs the DC/DC-stage to compensate the LF (third-harmonic) CM voltage inherently generated by the CSR-stage, and thus controls the LF CM voltage between the DC output midpoint and PE to zero. This enables further a direct connection of the DC output midpoint to PE, where an additionally proposed ground current control (GCC) ensures near-zero LF CM leakage current. The proposed concepts are verified with a 10kW hardware demonstrator (power density of 6.4 kW/dm3 or 107.5 W/in3, full-load peak efficiency of 98.5%) considering TT (Terra-Terra) and TN (Terra-Neutral) grounding systems. With a direct connection of the DC output midpoint to PE, GCC limits the LF CM leakage current to < 6mA RMS, i.e., significantly below typical RCD trip levels, and, using the human-body impedance model according to UL 2202, achieves a test voltage of 110mV that is clearly below the most stringent limit (250 mV) of the standard.
- 5 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (1) , 1398-1413
Nonisolated Three-Phase Current DC-Link Buck–Boost EV Charger With Virtual Output Midpoint Grounding and Ground Current Control
Non-isolated three-phase AC/DC converter concepts facilitate more compact and more efficient realizations of future EV chargers. However, without the galvanic isolation and/or high common-mode (CM) impedance provided by an isolation transformer, non-isolated chargers must employ other means to suppress CM leakage currents to ground sufficiently and to prevent nuisance tripping of mandatory residual current devices (RCDs). Typically, the required EMI filters reduce high-frequency (HF) CM leakage currents to uncritical values. However, low-frequency CM voltages, e.g., generated by third-harmonic injection, may drive significant LF CM currents through the parasitic capacitances of the DC output (including the battery pack) to protective earth (PE). Therefore, considering a non-isolated three-phase buck-boost current DC-link PFC rectifier system that consists of a buck-type current-source rectifier (CSR) stage and a three-level boost-type DC/DC-stage, this paper first proposes a virtual grounding control (VGC) of the DC output voltage midpoint. VGC employs the DC/DC-stage to compensate the LF (third-harmonic) CM voltage inherently generated by the CSR-stage, and thus controls the LF CM voltage between the DC output midpoint and PE to zero. This enables further a direct connection of the DC output midpoint to PE, where an additionally proposed ground current control (GCC) ensures near-zero LF CM leakage current. The proposed concepts are verified with a 10kW hardware demonstrator (power density of 6.4 kW/dm3 or 107.5 W/in3, full-load peak efficiency of 98.5%) considering TT (Terra-Terra) and TN (Terra-Neutral) grounding systems. With a direct connection of the DC output midpoint to PE, GCC limits the LF CM leakage current to < 6mA RMS, i.e., significantly below typical RCD trip levels, and, using the human-body impedance model according to UL 2202, achieves a test voltage of 110mV that is clearly below the most stringent limit (250 mV) of the standard.
- 14 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (3) , 3409-3423
Detailed Modeling and In-Situ Calorimetric Verification of Three-Phase Sparse NPC Converter Power Semiconductor Losses
The three-phase three-level (3-L) Sparse Neutral Point Clamped Converter (SNPCC) combines a 3-L matrix stage and a three-phase two-level inverter stage to generate 3-L switched output voltages with a reduced transistor count (10 instead of 12 or 18) compared to the classical 3-L NPCC or 3-L active NPCC structure, targeting variable-speed drive systems with low ripple of the motor phase currents or bidirectional three-phase PFC rectifier systems with reduced boost inductor volume. This paper analyzes and experimentally characterizes the performance of an IGBT-based three-phase 3-L SNPCC converter, and describes for the first time a hybrid current commutation effect between inverter-stage diodes and matrix-stage IGBTs that occurs when operating with lower modulation indices and leads to increased switching losses (up to 20%). The proposed new semiconductor loss modeling approach accounts for this effect successfully, which is verified (< 10% error) on an 800V dc , 7.5kW SNPCC hardware demonstrator using a new in-situ calorimetric method that facilitates accurate stage-level semiconductor loss measurements. Heat spreading effects caused by the asymmetrical losses injection and thermal decoupling between two in-situ loss measurement blocks are carefully checked with FEM simulations. Further, an experimental evaluation of common-mode and differential-mode high-frequency voltage-time area ripples (as a generic measure for the required filtering effort) for three typical symmetrical and asymmetrical modulation switching state sequences is provided together with the semiconductor loss characterization. Utilizing a low-switching-loss asymmetric modulation scheme that operates the 3-L matrix stage and the 2-L inverter stage with effective switching frequencies of 16kHz and 5.3kHz, respectively, the 3-L SNPCC demonstrator finally achieves a high rated-power (7.5kW, load current phase shift ϕ = 0) semiconductor efficiency of 98.8%.
- 14 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (3) , 3409-3423
Detailed Modeling and In-Situ Calorimetric Verification of Three-Phase Sparse NPC Converter Power Semiconductor Losses
The three-phase three-level (3-L) Sparse Neutral Point Clamped Converter (SNPCC) combines a 3-L matrix stage and a three-phase two-level inverter stage to generate 3-L switched output voltages with a reduced transistor count (10 instead of 12 or 18) compared to the classical 3-L NPCC or 3-L active NPCC structure, targeting variable-speed drive systems with low ripple of the motor phase currents or bidirectional three-phase PFC rectifier systems with reduced boost inductor volume. This paper analyzes and experimentally characterizes the performance of an IGBT-based three-phase 3-L SNPCC converter, and describes for the first time a hybrid current commutation effect between inverter-stage diodes and matrix-stage IGBTs that occurs when operating with lower modulation indices and leads to increased switching losses (up to 20%). The proposed new semiconductor loss modeling approach accounts for this effect successfully, which is verified (< 10% error) on an 800V dc , 7.5kW SNPCC hardware demonstrator using a new in-situ calorimetric method that facilitates accurate stage-level semiconductor loss measurements. Heat spreading effects caused by the asymmetrical losses injection and thermal decoupling between two in-situ loss measurement blocks are carefully checked with FEM simulations. Further, an experimental evaluation of common-mode and differential-mode high-frequency voltage-time area ripples (as a generic measure for the required filtering effort) for three typical symmetrical and asymmetrical modulation switching state sequences is provided together with the semiconductor loss characterization. Utilizing a low-switching-loss asymmetric modulation scheme that operates the 3-L matrix stage and the 2-L inverter stage with effective switching frequencies of 16kHz and 5.3kHz, respectively, the 3-L SNPCC demonstrator finally achieves a high rated-power (7.5kW, load current phase shift ϕ = 0) semiconductor efficiency of 98.8%.
- Open Access
- 14 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Level Boost-Buck Voltage DC-Link Very Wide Output Voltage Range EV Charger
Universal high-power three-phase mains interfaces for electric vehicle (EV) charging must provide a wide output voltage range (e.g., 200V to 800V) and thus provide buck and boost capability. An advantageous realization combining a three-level (3-L) T-type (Vienna) boost-type PFC voltage-source rectifier (VSR) with a 3-L buck-type DC/DC converter stage is presented in this paper. For high output voltages (boost-mode), the VSR-stage operates with 3/3-PWM, i.e., continuous PWM of all three phases to regulate the output voltage while the DC/DC-stage remains clamped to avoid switching losses. For low output voltages (buck-mode), the DC/DC-stage advantageously controls the DC-link voltage according to a time-varying reference value, which allows to sinusoidally shape the currents of two mains phases, such that the VSR-stage can operate with 1/3-PWM (only one of the three bridge-legs operates with PWM at any given time) with reduced switching losses. This paper proposes a novel 2/3-PWM scheme for the output voltage transition region, where output voltages are between the buck-mode and the boost-mode. This enables loss-optimum operation (i.e., the minimum number of the VSR-stage bridge-legs operating with PWM, and with the minimum possible DC-link voltage) for any output voltage. Furthermore, this paper introduces a new synergetic control concept that ensures seamless transitions between the loss-optimum operating modes. A comprehensive experimental verification, including pre-compliance EMI measurements, using a 10-kW hardware demonstrator with a power density of 5.4kW/L, a peak efficiency of 98.8% at rated power and 560V output voltage, and >98% efficiency for all operating points with >400V output voltage and more than about 50% of rated power, confirms the theoretical analyses.
- 14 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessLevel Boost-Buck Voltage DC-Link Very Wide Output Voltage Range EV Charger
Universal high-power three-phase mains interfaces for electric vehicle (EV) charging must provide a wide output voltage range (e.g., 200V to 800V) and thus provide buck and boost capability. An advantageous realization combining a three-level (3-L) T-type (Vienna) boost-type PFC voltage-source rectifier (VSR) with a 3-L buck-type DC/DC converter stage is presented in this paper. For high output voltages (boost-mode), the VSR-stage operates with 3/3-PWM, i.e., continuous PWM of all three phases to regulate the output voltage while the DC/DC-stage remains clamped to avoid switching losses. For low output voltages (buck-mode), the DC/DC-stage advantageously controls the DC-link voltage according to a time-varying reference value, which allows to sinusoidally shape the currents of two mains phases, such that the VSR-stage can operate with 1/3-PWM (only one of the three bridge-legs operates with PWM at any given time) with reduced switching losses. This paper proposes a novel 2/3-PWM scheme for the output voltage transition region, where output voltages are between the buck-mode and the boost-mode. This enables loss-optimum operation (i.e., the minimum number of the VSR-stage bridge-legs operating with PWM, and with the minimum possible DC-link voltage) for any output voltage. Furthermore, this paper introduces a new synergetic control concept that ensures seamless transitions between the loss-optimum operating modes. A comprehensive experimental verification, including pre-compliance EMI measurements, using a 10-kW hardware demonstrator with a power density of 5.4kW/L, a peak efficiency of 98.8% at rated power and 560V output voltage, and >98% efficiency for all operating points with >400V output voltage and more than about 50% of rated power, confirms the theoretical analyses.
- 15 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (4) , 4195-4202
Three-Phase Synergetically Controlled Current DC-Link AC/DC Buck–Boost Converter With Two Independently Regulated DC Outputs
A three-phase current DC-link AC/DC buck-boost converter, composed of a three-phase current-source rectifier (CSR) front-end and a three-level DC/DC-stage, can provide two independently regulated DC outputs. A conventional synergetic control strategy, which coordinates the modulation of the CSR and the DC/DC converter stage to achieve minimum overall switching losses, is extended to the case of two independent DC outputs, retaining all advantageous features such as seamless transitions between operating modes and modulation schemes. The extended synergetic control strategy allows loss-optimum operation (i.e., reduced number of switching instants due to clamping of a phase of the CSR-stage (switching only two out of the three phases, i.e., 2/3-PWM) or individual clamping of the DC/DC-stage's two half-bridges, and minimum possible DC-link current) for any operating point, especially also for two different output voltages and/or two different loads. Finally, experimental confirmation of the proposed control scheme using a 10 kW demonstrator system is provided. Operating in the boost-mode at a total output voltage of 800 V, the proposed synergetic control achieves a significant measured efficiency improvement over a wide load range, e.g., from 95.7% to 96.9% (1.2%) at 2 kW and from 97.9% to 98.4% (0.5%) at 10 kW, which is largely independent of output voltage asymmetries and load asymmetries..
- 15 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (4) , 4195-4202
Three-Phase Synergetically Controlled Current DC-Link AC/DC Buck–Boost Converter With Two Independently Regulated DC Outputs
A three-phase current DC-link AC/DC buck-boost converter, composed of a three-phase current-source rectifier (CSR) front-end and a three-level DC/DC-stage, can provide two independently regulated DC outputs. A conventional synergetic control strategy, which coordinates the modulation of the CSR and the DC/DC converter stage to achieve minimum overall switching losses, is extended to the case of two independent DC outputs, retaining all advantageous features such as seamless transitions between operating modes and modulation schemes. The extended synergetic control strategy allows loss-optimum operation (i.e., reduced number of switching instants due to clamping of a phase of the CSR-stage (switching only two out of the three phases, i.e., 2/3-PWM) or individual clamping of the DC/DC-stage's two half-bridges, and minimum possible DC-link current) for any operating point, especially also for two different output voltages and/or two different loads. Finally, experimental confirmation of the proposed control scheme using a 10 kW demonstrator system is provided. Operating in the boost-mode at a total output voltage of 800 V, the proposed synergetic control achieves a significant measured efficiency improvement over a wide load range, e.g., from 95.7% to 96.9% (1.2%) at 2 kW and from 97.9% to 98.4% (0.5%) at 10 kW, which is largely independent of output voltage asymmetries and load asymmetries..