Accuracy of Fully Guided Implant Placement Using Bone-Supported Stackable Surgical Guides in Completely Edentulous Patients—A Retrospective Study
Open Access
- 14 January 2026
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 652
Abstract
Background/Objectives: Precise implant positioning is critical for successful prosthetic rehabilitation, particularly in completely edentulous patients where anatomical landmarks are lost. The aim of this study was to assess the accuracy of implant placement in the edentulous maxilla and mandible using computer-assisted planning and a bone-supported stackable surgical guide protocol. Methods: This retrospective clinical study included 15 completely edentulous patients who received a total of 60 implants. A dual-scan protocol was utilized for planning. The surgical protocol involved a base guide fixed to the bone with pins, serving as a rigid foundation for stackable components used for osteotomy and implant insertion. Postoperative CBCT scans were superimposed onto the preoperative plan to calculate angular deviations, 3D linear deviations at the implant neck and apex, and depth deviations. Results: The analysis demonstrated high accuracy with a mean angular deviation of 1.25° ± 0.80°. The mean 3D linear deviation was 0.96 ± 0.57 mm at the implant neck and 1.07 ± 0.56 mm at the apex. Depth deviation showed a mean discrepancy of 0.37 ± 0.58 mm. All measured parameters were statistically significantly lower (p < 0.05) than the pre-established clinical safety thresholds. Conclusions: Within the limitations of this study, the bone-supported stackable surgical guide protocol proved to be a highly accurate method for full-arch rehabilitation. By eliminating mucosal resilience and ensuring rigid fixation, this approach enables predictable implant placement and facilitates the passive fit of screw-retained bar-supported prostheses, representing a reliable alternative to dynamic navigation in daily clinical practice.Keywords
Funding Information
- National Recovery and Resilience Plan (SFZG-05-2025)
This publication has 28 references indexed in Scilit:
- Comparison of Accuracy of Dental Implant Placement Between Freehand and Guided Implant Surgery—A Systematic Review and Meta-analysisJournal of Maxillofacial and Oral Surgery, 2025
- Stackable GuidesOral and Maxillofacial Surgery Clinics of North America, 2025
- Stackable guide in implantology: A technical noteJournal of Stomatology Oral and Maxillofacial Surgery, 2023
- Is there a learning curve in static computer-assisted implant surgery? A prospective clinical studyInternational Journal of Oral and Maxillofacial Surgery, 2020
- Proceedings of the 6th ITI Consensus ConferenceClinical Oral Implants Research, 2018
- Group 5 ITI Consensus Report: Digital technologiesClinical Oral Implants Research, 2018
- Implant Placement Is More Accurate Using Dynamic NavigationJournal of Oral and Maxillofacial Surgery, 2017
- Deviations between Placed and Planned Implant Positions: An Accuracy Pilot Study of Skeletally Supported Stereolithographic Surgical TemplatesClinical Implant Dentistry and Related Research, 2012
- Effect of Passive Fit Absence in the Prosthesis/Implant/Retaining Screw SystemJournal of Craniofacial Surgery, 2009
- Clinical Accuracy of 3 Different Types of Computed Tomography-Derived Stereolithographic Surgical Guides in Implant PlacementJournal of Oral and Maxillofacial Surgery, 2009