Luka Stojić
Research Subjects
Research Interests
Luka Stojić has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Marko Vuletić
Department of Oral Surgery, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
3 shared publications - Dragana Gabrić
Department of Oral Surgery, School of Dental Medicine, University of Zagreb, HR-10000 Zagreb, Croatia
2 shared publications - Igor Smojver
Department of Oral Surgery, School of Dental Medicine, University of Zagreb, HR-10000 Zagreb, Croatia
2 shared publications - Roko Bjelica
Department of Oral Surgery, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
2 shared publications - Ante Jordan
Department of Oral Surgery, Dental Polyclinic Zagreb, 10000 Zagreb, Croatia
1 shared publication - Dragana Gabrić
Department of Oral Surgery, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
1 shared publication
Latest Publications
- Open Access
- 17 April 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (4) , 194
Accuracy of Static Computer-Aided Implant Surgery: A Clinical Comparison of Tooth-, Bone-, and Mucosa-Supported Surgical Guides
The accuracy of static computer-aided implant surgery (s-CAIS) is fundamental for predictable clinical outcomes. The objective of this study was to evaluate the influence of different guide-support modalities on the linear and angular accuracy of implant placement. In this retrospective clinical investigation conducted at a single specialty hospital, a total of 180 implants were analyzed, divided into three equal groups (n = 60) based on the guide support type: tooth-supported, bone-supported, and mucosa-supported. Accuracy was assessed by superimposing preoperative virtual plans with postoperative cone-beam computed tomography (CBCT) scans, measuring linear deviations at the neck and apex of the implant, as well as angular discrepancies. The type of guide support was found to be a significant factor associated with surgical accuracy (p < 0.001). Tooth-supported guides demonstrated the highest level of accuracy, with a mean angular deviation of 1.81° ± 0.45° and linear deviations at the neck and apex of 0.59 ± 0.18 mm and 0.73 ± 0.19 mm, respectively. These were followed by bone-supported guides (2.14° ± 0.48°; 1.04 ± 0.26 mm; 1.61 ± 0.31 mm), while mucosa-supported guides exhibited the greatest deviations (2.95° ± 0.60°; 1.47 ± 0.29 mm; 1.87 ± 0.37 mm). Significant intergroup differences and large effect sizes were observed, particularly regarding angular and horizontal discrepancies. These findings demonstrate a distinct gradient of accuracy based on guide support, establishing tooth-supported guides as the most accurate, followed by bone-supported and, lastly, mucosa-supported guides. While all modalities are clinically applicable, the use of mucosa-supported guides necessitates increased safety margins to account for the increased risk of linear and angular discrepancies inherent to mucosal tissue displacement.
- 17 April 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (4) , 194
Open AccessAccuracy of Static Computer-Aided Implant Surgery: A Clinical Comparison of Tooth-, Bone-, and Mucosa-Supported Surgical Guides
The accuracy of static computer-aided implant surgery (s-CAIS) is fundamental for predictable clinical outcomes. The objective of this study was to evaluate the influence of different guide-support modalities on the linear and angular accuracy of implant placement. In this retrospective clinical investigation conducted at a single specialty hospital, a total of 180 implants were analyzed, divided into three equal groups (n = 60) based on the guide support type: tooth-supported, bone-supported, and mucosa-supported. Accuracy was assessed by superimposing preoperative virtual plans with postoperative cone-beam computed tomography (CBCT) scans, measuring linear deviations at the neck and apex of the implant, as well as angular discrepancies. The type of guide support was found to be a significant factor associated with surgical accuracy (p < 0.001). Tooth-supported guides demonstrated the highest level of accuracy, with a mean angular deviation of 1.81° ± 0.45° and linear deviations at the neck and apex of 0.59 ± 0.18 mm and 0.73 ± 0.19 mm, respectively. These were followed by bone-supported guides (2.14° ± 0.48°; 1.04 ± 0.26 mm; 1.61 ± 0.31 mm), while mucosa-supported guides exhibited the greatest deviations (2.95° ± 0.60°; 1.47 ± 0.29 mm; 1.87 ± 0.37 mm). Significant intergroup differences and large effect sizes were observed, particularly regarding angular and horizontal discrepancies. These findings demonstrate a distinct gradient of accuracy based on guide support, establishing tooth-supported guides as the most accurate, followed by bone-supported and, lastly, mucosa-supported guides. While all modalities are clinically applicable, the use of mucosa-supported guides necessitates increased safety margins to account for the increased risk of linear and angular discrepancies inherent to mucosal tissue displacement.
- Open Access
- 14 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 652
Accuracy of Fully Guided Implant Placement Using Bone-Supported Stackable Surgical Guides in Completely Edentulous Patients—A Retrospective Study
Background/Objectives: Precise implant positioning is critical for successful prosthetic rehabilitation, particularly in completely edentulous patients where anatomical landmarks are lost. The aim of this study was to assess the accuracy of implant placement in the edentulous maxilla and mandible using computer-assisted planning and a bone-supported stackable surgical guide protocol. Methods: This retrospective clinical study included 15 completely edentulous patients who received a total of 60 implants. A dual-scan protocol was utilized for planning. The surgical protocol involved a base guide fixed to the bone with pins, serving as a rigid foundation for stackable components used for osteotomy and implant insertion. Postoperative CBCT scans were superimposed onto the preoperative plan to calculate angular deviations, 3D linear deviations at the implant neck and apex, and depth deviations. Results: The analysis demonstrated high accuracy with a mean angular deviation of 1.25° ± 0.80°. The mean 3D linear deviation was 0.96 ± 0.57 mm at the implant neck and 1.07 ± 0.56 mm at the apex. Depth deviation showed a mean discrepancy of 0.37 ± 0.58 mm. All measured parameters were statistically significantly lower (p < 0.05) than the pre-established clinical safety thresholds. Conclusions: Within the limitations of this study, the bone-supported stackable surgical guide protocol proved to be a highly accurate method for full-arch rehabilitation. By eliminating mucosal resilience and ensuring rigid fixation, this approach enables predictable implant placement and facilitates the passive fit of screw-retained bar-supported prostheses, representing a reliable alternative to dynamic navigation in daily clinical practice.
- 14 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 652
Open AccessAccuracy of Fully Guided Implant Placement Using Bone-Supported Stackable Surgical Guides in Completely Edentulous Patients—A Retrospective Study
Background/Objectives: Precise implant positioning is critical for successful prosthetic rehabilitation, particularly in completely edentulous patients where anatomical landmarks are lost. The aim of this study was to assess the accuracy of implant placement in the edentulous maxilla and mandible using computer-assisted planning and a bone-supported stackable surgical guide protocol. Methods: This retrospective clinical study included 15 completely edentulous patients who received a total of 60 implants. A dual-scan protocol was utilized for planning. The surgical protocol involved a base guide fixed to the bone with pins, serving as a rigid foundation for stackable components used for osteotomy and implant insertion. Postoperative CBCT scans were superimposed onto the preoperative plan to calculate angular deviations, 3D linear deviations at the implant neck and apex, and depth deviations. Results: The analysis demonstrated high accuracy with a mean angular deviation of 1.25° ± 0.80°. The mean 3D linear deviation was 0.96 ± 0.57 mm at the implant neck and 1.07 ± 0.56 mm at the apex. Depth deviation showed a mean discrepancy of 0.37 ± 0.58 mm. All measured parameters were statistically significantly lower (p < 0.05) than the pre-established clinical safety thresholds. Conclusions: Within the limitations of this study, the bone-supported stackable surgical guide protocol proved to be a highly accurate method for full-arch rehabilitation. By eliminating mucosal resilience and ensuring rigid fixation, this approach enables predictable implant placement and facilitates the passive fit of screw-retained bar-supported prostheses, representing a reliable alternative to dynamic navigation in daily clinical practice.
- Open Access
Nasal Floor Elevation—An Option of Premaxilla Augmentation: A Case Report
The atrophic edentulous maxilla is demanding for dental implant placement because of extensive resorption of the alveolar ridge after teeth loss and, consequently, the proximity of the anatomical structures, nasal cavity, and maxillary sinus. Treatment options are short implants, guided bone regeneration, onlay grafts, Le Fort I osteotomy with interpositional bone grafting, distraction osteogenesis, or nasal floor elevation. Nasal floor elevation is a method of augmentation of premaxilla by raising the base of the nose. The aim of this case report is to evaluate the success of implants placed after nasal floor elevation. A 75-year-old female patient came to the Clinical Department of Oral Surgery, University Hospital Centre Zagreb, unsatisfied with her complete removable denture. Clinical and radiological examination revealed severe maxillary alveolar ridge atrophy. Nasal floor elevation was made under local anesthesia through aperture piriformis and lateral window in the distal part. After eight months, four implants were placed and, after period of osseointegration, a bar-retained implant overdenture was made. This case report shows that nasal floor augmentation can be considered among the surgical techniques to allow implant-supported rehabilitation of the atrophic anterior maxilla.
Open AccessNasal Floor Elevation—An Option of Premaxilla Augmentation: A Case Report
The atrophic edentulous maxilla is demanding for dental implant placement because of extensive resorption of the alveolar ridge after teeth loss and, consequently, the proximity of the anatomical structures, nasal cavity, and maxillary sinus. Treatment options are short implants, guided bone regeneration, onlay grafts, Le Fort I osteotomy with interpositional bone grafting, distraction osteogenesis, or nasal floor elevation. Nasal floor elevation is a method of augmentation of premaxilla by raising the base of the nose. The aim of this case report is to evaluate the success of implants placed after nasal floor elevation. A 75-year-old female patient came to the Clinical Department of Oral Surgery, University Hospital Centre Zagreb, unsatisfied with her complete removable denture. Clinical and radiological examination revealed severe maxillary alveolar ridge atrophy. Nasal floor elevation was made under local anesthesia through aperture piriformis and lateral window in the distal part. After eight months, four implants were placed and, after period of osseointegration, a bar-retained implant overdenture was made. This case report shows that nasal floor augmentation can be considered among the surgical techniques to allow implant-supported rehabilitation of the atrophic anterior maxilla.