Purpose: In this study, the dosimetric effect of baseline shift (BLS) in a magnetic resonance linear accelerator was investigated and compared with adapt‐to‐position (ATP), adapt‐to‐shape (ATS), and an uncorrected plan without adaptation. Methods: In a simulation dataset consisting of 30 patients (10 prostate, 10 liver, 10 pancreatic), all structures were rigidly shifted by 1, 3, 5, and 10 mm separately in the superior–inferior and posterior directions, and four plans (ATS reoptimization, ATP reoptimization, BLS using the segment aperture morphing algorithm, and an uncorrected plan without adaptation) were generated for each shift condition. Planning target volume (PTV) coverage and PTV maximum dose (Dmax) were then compared. The dosimetric effects of BLS on the targets and organs at risk (OARs) under non‐rigid anatomic changes were also evaluated using a clinical dataset based on magnetic resonance imaging acquired during treatment. Results: In the simulation analysis of superior–inferior shifts, target coverage using BLS was comparable to that using ATS and ATP across all disease sites and improved compared with that using the uncorrected plan. For posterior shifts, target coverage remained comparable to that using ATS and ATP; however, BLS increased the PTV Dmax at all posterior shift magnitudes (1–10 mm) in prostate and pancreatic cases, with limited increases in liver cases. In the clinical dataset, OAR doses upon left–right or anterior–posterior displacement were greater using BLS than using ATP, ATS, and uncorrected plans in the prostate and pancreatic cases, with limited increases in the liver cases. Conclusions: The dosimetric impact of BLS relies on motion direction and plan characteristics. BLS was stable for superior–inferior shifts, whereas posterior shifts may increase PTV hotspots and OAR doses. Therefore, clinical application of BLS should consider motion direction and plan design rather than applying a uniform strategy.Keywords
Funding Information
- Japan Society for the Promotion of Science (JP23K07077)
This publication has 24 references indexed in Scilit:
- First clinical application of Comprehensive Motion Management with 1.5T MR-linac on prostate cancer patients treated with radiotherapy: technical aspects and suggested workflow recommendationsLa radiologia medica, 2025
- Patient setup variation on Elekta Unity and its impact on adaptive planningJournal of Applied Clinical Medical Physics, 2025
- Treatment planning evaluation and experimental validation of the magnetic resonance-based intrafraction drift correctionPhysics and Imaging in Radiation Oncology, 2024
- Is it necessary to perform measurement‐based patient‐specific quality assurance for online adaptive radiotherapy with Elekta Unity MR‐Linac?Journal of Applied Clinical Medical Physics, 2023
- Evaluation of Unity 1.5 T MR‐linac plan quality in patients with prostate cancerJournal of Applied Clinical Medical Physics, 2023
- Introduction of radiation therapist‐led adaptive treatments on a 1.5 T MR‐LinacJournal of Medical Radiation Sciences, 2022
- Risk analysis of the Unity 1.5 T MR‐Linac adapt‐to‐position workflowJournal of Applied Clinical Medical Physics, 2022
- Intrafraction pancreatic tumor motion patterns during ungated magnetic resonance guided radiotherapy with an abdominal corsetPhysics and Imaging in Radiation Oncology, 2021
- Future mainstream platform for online adaptive radiotherapy will be using on‐board MR rather than on‐board (CB) CT imagesJournal of Applied Clinical Medical Physics, 2021
- Three-dimensional, Time-Resolved, Intrafraction Motion Monitoring Throughout Stereotactic Liver Radiation Therapy on a Conventional Linear AcceleratorInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013