Shohei Tanaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Shohei Tanaka has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Noriyuki Kadoya
Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan
5 shared publications Keiichi Jingu
Department of Radiation Oncology Tohoku University Graduate School of Medicine Sendai Japan
4 shared publications- Yoshiyuki Katsuta
Department of Radiation Oncology Tohoku University Graduate School of Medicine Sendai Japan
4 shared publications Kazuhiro Arai
Department of Radiation Oncology Tohoku University Graduate School of Medicine Sendai Japan
3 shared publications- Keiichi Jingu
Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan
3 shared publications Noriyoshi Takahashi
Department of Radiation Oncology Tohoku University Graduate School of Medicine Sendai Japan
3 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11) , e70861
Dosimetric impact of baseline shift plan in a magnetic resonance linear accelerator according to target motion and plan characteristics
Purpose: In this study, the dosimetric effect of baseline shift (BLS) in a magnetic resonance linear accelerator was investigated and compared with adapt‐to‐position (ATP), adapt‐to‐shape (ATS), and an uncorrected plan without adaptation. Methods: In a simulation dataset consisting of 30 patients (10 prostate, 10 liver, 10 pancreatic), all structures were rigidly shifted by 1, 3, 5, and 10 mm separately in the superior–inferior and posterior directions, and four plans (ATS reoptimization, ATP reoptimization, BLS using the segment aperture morphing algorithm, and an uncorrected plan without adaptation) were generated for each shift condition. Planning target volume (PTV) coverage and PTV maximum dose (Dmax) were then compared. The dosimetric effects of BLS on the targets and organs at risk (OARs) under non‐rigid anatomic changes were also evaluated using a clinical dataset based on magnetic resonance imaging acquired during treatment. Results: In the simulation analysis of superior–inferior shifts, target coverage using BLS was comparable to that using ATS and ATP across all disease sites and improved compared with that using the uncorrected plan. For posterior shifts, target coverage remained comparable to that using ATS and ATP; however, BLS increased the PTV Dmax at all posterior shift magnitudes (1–10 mm) in prostate and pancreatic cases, with limited increases in liver cases. In the clinical dataset, OAR doses upon left–right or anterior–posterior displacement were greater using BLS than using ATP, ATS, and uncorrected plans in the prostate and pancreatic cases, with limited increases in the liver cases. Conclusions: The dosimetric impact of BLS relies on motion direction and plan characteristics. BLS was stable for superior–inferior shifts, whereas posterior shifts may increase PTV hotspots and OAR doses. Therefore, clinical application of BLS should consider motion direction and plan design rather than applying a uniform strategy.
- 20 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11) , e70861
Open AccessDosimetric impact of baseline shift plan in a magnetic resonance linear accelerator according to target motion and plan characteristics
Purpose: In this study, the dosimetric effect of baseline shift (BLS) in a magnetic resonance linear accelerator was investigated and compared with adapt‐to‐position (ATP), adapt‐to‐shape (ATS), and an uncorrected plan without adaptation. Methods: In a simulation dataset consisting of 30 patients (10 prostate, 10 liver, 10 pancreatic), all structures were rigidly shifted by 1, 3, 5, and 10 mm separately in the superior–inferior and posterior directions, and four plans (ATS reoptimization, ATP reoptimization, BLS using the segment aperture morphing algorithm, and an uncorrected plan without adaptation) were generated for each shift condition. Planning target volume (PTV) coverage and PTV maximum dose (Dmax) were then compared. The dosimetric effects of BLS on the targets and organs at risk (OARs) under non‐rigid anatomic changes were also evaluated using a clinical dataset based on magnetic resonance imaging acquired during treatment. Results: In the simulation analysis of superior–inferior shifts, target coverage using BLS was comparable to that using ATS and ATP across all disease sites and improved compared with that using the uncorrected plan. For posterior shifts, target coverage remained comparable to that using ATS and ATP; however, BLS increased the PTV Dmax at all posterior shift magnitudes (1–10 mm) in prostate and pancreatic cases, with limited increases in liver cases. In the clinical dataset, OAR doses upon left–right or anterior–posterior displacement were greater using BLS than using ATP, ATS, and uncorrected plans in the prostate and pancreatic cases, with limited increases in the liver cases. Conclusions: The dosimetric impact of BLS relies on motion direction and plan characteristics. BLS was stable for superior–inferior shifts, whereas posterior shifts may increase PTV hotspots and OAR doses. Therefore, clinical application of BLS should consider motion direction and plan design rather than applying a uniform strategy.
- Open Access
- 27 April 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (2) , 792-805
Optimal timing of the cumulative dose and factors related to acute urinary toxicity in prostate cancer treated using magnetic resonance linear accelerator
The online version contains supplementary material available at 10.1007/s12194-026-01056-8.
- 27 April 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (2) , 792-805
Open AccessOptimal timing of the cumulative dose and factors related to acute urinary toxicity in prostate cancer treated using magnetic resonance linear accelerator
The online version contains supplementary material available at 10.1007/s12194-026-01056-8.
- Open Access
- 27 November 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (12) , e70403
Development and evaluation of deep learning models for estimating the organ at‐risk dose constraint from two‐dimensional cine magnetic resonance imaging scans during irradiation
Purpose: Two‐dimensional (2D) cine magnetic resonance imaging (MRI), available with a MR‐linear accelerator (MR‐Linac), allows real‐time visualization of anatomical information during irradiation. The present study aimed to develop and evaluate a deep learning model that can estimate the organ‐at‐risk (OAR) dose constraints (mainly bladder V37Gy) from 2D cine MRI. Methods: The present study enrolled 91 prostate cancer patients treated with MR‐Linac. From 381 treatment fractions, sagittal images at the start and end of the 2D cine MRI were extracted. Additionally, 3D MRI data acquired pre‐ and post‐irradiation were collected, from which bladder V37Gy was calculated. We designed the deep learning model to predict the end‐of‐irradiation bladder V37Gy value based on the bladder image on the end‐of‐irradiation 2D cine MRI. The model inputs included the start and end 2D cine MR images, a difference image between them, and the pre‐irradiation bladder V37Gy. The model output was the post‐irradiation bladder V37Gy. We utilized a five‐fold cross‐validation for model training and evaluated the performance using a test dataset. For reference, we also evaluated the predictions made using only the pre‐irradiation bladder V37Gy. Results: In the test dataset, the model‐predicted and true bladder V37Gy values showed a strong correlation ( r = 0.89), with a mean absolute error (MAE) of 1.40 cm 3 . Using only the pre‐irradiation bladder V37Gy value yielded an r of 0.79 and an MAE of 2.02 cm 3 . Our model also achieved an area under the curve, sensitivity, and specificity values of 0.98, 0.91, and 0.95, respectively, in detecting dose constraint violations (bladder V37Gy of > 10 cm 3 ). Conclusions: Our results demonstrated that deep learning can effectively predict the OAR dose constraints during irradiation. However, it is noteworthy that these results show only a limited improvement and are constrained by several limitations.
- 27 November 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (12) , e70403
Open AccessDevelopment and evaluation of deep learning models for estimating the organ at‐risk dose constraint from two‐dimensional cine magnetic resonance imaging scans during irradiation
Purpose: Two‐dimensional (2D) cine magnetic resonance imaging (MRI), available with a MR‐linear accelerator (MR‐Linac), allows real‐time visualization of anatomical information during irradiation. The present study aimed to develop and evaluate a deep learning model that can estimate the organ‐at‐risk (OAR) dose constraints (mainly bladder V37Gy) from 2D cine MRI. Methods: The present study enrolled 91 prostate cancer patients treated with MR‐Linac. From 381 treatment fractions, sagittal images at the start and end of the 2D cine MRI were extracted. Additionally, 3D MRI data acquired pre‐ and post‐irradiation were collected, from which bladder V37Gy was calculated. We designed the deep learning model to predict the end‐of‐irradiation bladder V37Gy value based on the bladder image on the end‐of‐irradiation 2D cine MRI. The model inputs included the start and end 2D cine MR images, a difference image between them, and the pre‐irradiation bladder V37Gy. The model output was the post‐irradiation bladder V37Gy. We utilized a five‐fold cross‐validation for model training and evaluated the performance using a test dataset. For reference, we also evaluated the predictions made using only the pre‐irradiation bladder V37Gy. Results: In the test dataset, the model‐predicted and true bladder V37Gy values showed a strong correlation ( r = 0.89), with a mean absolute error (MAE) of 1.40 cm 3 . Using only the pre‐irradiation bladder V37Gy value yielded an r of 0.79 and an MAE of 2.02 cm 3 . Our model also achieved an area under the curve, sensitivity, and specificity values of 0.98, 0.91, and 0.95, respectively, in detecting dose constraint violations (bladder V37Gy of > 10 cm 3 ). Conclusions: Our results demonstrated that deep learning can effectively predict the OAR dose constraints during irradiation. However, it is noteworthy that these results show only a limited improvement and are constrained by several limitations.
- Open Access
- 30 October 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (10) , e0312032
Investigation of intrafractional spinal cord and spinal canal movement during stereotactic MR-guided online adaptive radiotherapy for kidney cancer
Background and purpose: This study aimed to investigate the intrafractional movement of the spinal cord and spinal canal during MR-guided online adaptive radiotherapy (MRgART) for kidney cancer. Materials and methods: All patients who received stereotactic MRgART for kidney cancer between February 2022 and February 2024 were included in this study. Patients received 30–42 Gy in 3-fraction MRgART for kidney cancer using the Elekta Unity, which is equipped with a linear accelerator and a 1.5 Tesla MRI. MRI scans were performed at three points during each fraction: for online planning, position verification, and posttreatment assessment. The spinal cord was contoured from the upper edge of Th12 to the medullary cone, and the spinal canal was contoured from Th12 to L3, using the first MRI. These contours were adjusted to the second and third MR images via deformable image registration, and movements were measured. Margins were determined via the formula “1.3×Σ+0.5×σ” and 95% prediction intervals. Results: A total of 22 patients (66 fractions) were analyzed. The median interval between the first and third MRI scans were 38 minutes. The mean ± standard deviation of the spinal cord movements after this interval were −0.01 ± 0.06 for the x-axis (right–left), 0.01 ± 0.14 for the y-axis (caudal–cranial), 0.07 ± 0.05 for the z-axis (posterior–anterior), and 0.15 ± 0.08 for the 3D distance, respectively. The correlation coefficients of the 3D distance between the spinal cord and the spinal canal was high (0.92). The calculated planning organ at risk volume margin for all directions was 0.11 cm for spinal cord. The 95% prediction intervals for the x-axis, y-axis, and z-axis were −0.11–0.09 cm, −0.23–0.25 cm and −0.14–0.03 cm, respectively. Conclusions: Margins are necessary in MRgART to compensate for intrafractional movement and ensure safe treatment delivery.
- 30 October 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (10) , e0312032
Open AccessInvestigation of intrafractional spinal cord and spinal canal movement during stereotactic MR-guided online adaptive radiotherapy for kidney cancer
Background and purpose: This study aimed to investigate the intrafractional movement of the spinal cord and spinal canal during MR-guided online adaptive radiotherapy (MRgART) for kidney cancer. Materials and methods: All patients who received stereotactic MRgART for kidney cancer between February 2022 and February 2024 were included in this study. Patients received 30–42 Gy in 3-fraction MRgART for kidney cancer using the Elekta Unity, which is equipped with a linear accelerator and a 1.5 Tesla MRI. MRI scans were performed at three points during each fraction: for online planning, position verification, and posttreatment assessment. The spinal cord was contoured from the upper edge of Th12 to the medullary cone, and the spinal canal was contoured from Th12 to L3, using the first MRI. These contours were adjusted to the second and third MR images via deformable image registration, and movements were measured. Margins were determined via the formula “1.3×Σ+0.5×σ” and 95% prediction intervals. Results: A total of 22 patients (66 fractions) were analyzed. The median interval between the first and third MRI scans were 38 minutes. The mean ± standard deviation of the spinal cord movements after this interval were −0.01 ± 0.06 for the x-axis (right–left), 0.01 ± 0.14 for the y-axis (caudal–cranial), 0.07 ± 0.05 for the z-axis (posterior–anterior), and 0.15 ± 0.08 for the 3D distance, respectively. The correlation coefficients of the 3D distance between the spinal cord and the spinal canal was high (0.92). The calculated planning organ at risk volume margin for all directions was 0.11 cm for spinal cord. The 95% prediction intervals for the x-axis, y-axis, and z-axis were −0.11–0.09 cm, −0.23–0.25 cm and −0.14–0.03 cm, respectively. Conclusions: Margins are necessary in MRgART to compensate for intrafractional movement and ensure safe treatment delivery.
- Open Access
- 17 June 2023
- Published by Springer Nature in BMC Gastroenterology
- Vol. 23 (1) , 1-6
Risk of cardiovascular disease in lean patients with nonalcoholic fatty liver disease
Background: Patients with nonalcoholic fatty liver disease (NAFLD) are highly at risk for cardiovascular disease (CVD). However, the risk of developing CVD in patients with lean NAFLD is not yet fully understood. Therefore, this study aimed to compare the CVD incidence in Japanese patients with lean NAFLD and those with non-lean NAFLD. Methods: A total of 581 patients with NAFLD (219 with lean and 362 with non-lean NAFLD) were recruited. All patients underwent annual health checkups for at least 3 years, and CVD incidence was investigated during follow-up. The primary end-point was CVD incidence at 3 years. Results: The 3-year new CVD incidence rates in patients with lean and non-lean NAFLD were 2.3% and 3.9%, respectively, and there was no significant difference between two groups (p = 0.3). Multivariable analysis adjusted for age, sex, hypertension, diabetes, and lean NAFLD/non-lean NAFLD revealed that age (every 10 years) as an independent factor associated with CVD incidence with an odds ratio (OR) of 2.0 (95% confidence interval [CI]: 1.3–3.4), whereas lean NAFLD was not associated with CVD incidence (OR: 0.6; 95% CI: 0.2–1.9). Conclusions: CVD incidence was comparable between patients with lean NAFLD and those with non-lean NAFLD. Therefore, CVD prevention is needed even in patients with lean NAFLD.
- 17 June 2023
- Published by Springer Nature in BMC Gastroenterology
- Vol. 23 (1) , 1-6
Open AccessRisk of cardiovascular disease in lean patients with nonalcoholic fatty liver disease
Background: Patients with nonalcoholic fatty liver disease (NAFLD) are highly at risk for cardiovascular disease (CVD). However, the risk of developing CVD in patients with lean NAFLD is not yet fully understood. Therefore, this study aimed to compare the CVD incidence in Japanese patients with lean NAFLD and those with non-lean NAFLD. Methods: A total of 581 patients with NAFLD (219 with lean and 362 with non-lean NAFLD) were recruited. All patients underwent annual health checkups for at least 3 years, and CVD incidence was investigated during follow-up. The primary end-point was CVD incidence at 3 years. Results: The 3-year new CVD incidence rates in patients with lean and non-lean NAFLD were 2.3% and 3.9%, respectively, and there was no significant difference between two groups (p = 0.3). Multivariable analysis adjusted for age, sex, hypertension, diabetes, and lean NAFLD/non-lean NAFLD revealed that age (every 10 years) as an independent factor associated with CVD incidence with an odds ratio (OR) of 2.0 (95% confidence interval [CI]: 1.3–3.4), whereas lean NAFLD was not associated with CVD incidence (OR: 0.6; 95% CI: 0.2–1.9). Conclusions: CVD incidence was comparable between patients with lean NAFLD and those with non-lean NAFLD. Therefore, CVD prevention is needed even in patients with lean NAFLD.
- Open Access
- 31 May 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1354
Feasibility of Differential Dose—Volume Histogram Features in Multivariate Prediction Model for Radiation Pneumonitis Occurrence
The purpose of this study is to introduce differential dose–volume histogram (dDVH) features into machine learning for radiation pneumonitis (RP) prediction and to demonstrate the predictive performance of the developed model based on integrated cumulative dose–volume histogram (cDVH) and dDVH features. Materials and methods: cDVH and dDVH features were calculated for 153 patients treated for non-small-cell lung cancer with 60–66 Gy and dose bins ranging from 2 to 8 Gy in 2 Gy increments. RP prediction models were developed with the least absolute shrinkage and selection operator (LASSO) through fivefold cross-validation. Results: Among the 152 patients in the patient cohort, 41 presented ≥grade 2 RP. The interdependencies between cDVH features evaluated by Spearman’s correlation were significantly resolved by the inclusion of dDVH features. The average area under curve for the RP prediction model using cDVH and dDVH model was 0.73, which was higher than the average area under curve using cDVH model for 0.62 with statistically significance (p < 0.01). An analysis using the entire set of regression coefficients determined by LASSO demonstrated that dDVH features represented four of the top five frequently selected features in the model fitting, regardless of dose bin. Conclusions: We successfully developed an RP prediction model that integrated cDVH and dDVH features. The best RP prediction model was achieved using dDVH (dose bin = 4 Gy) features in the machine learning process.
- 31 May 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1354
Open AccessFeasibility of Differential Dose—Volume Histogram Features in Multivariate Prediction Model for Radiation Pneumonitis Occurrence
The purpose of this study is to introduce differential dose–volume histogram (dDVH) features into machine learning for radiation pneumonitis (RP) prediction and to demonstrate the predictive performance of the developed model based on integrated cumulative dose–volume histogram (cDVH) and dDVH features. Materials and methods: cDVH and dDVH features were calculated for 153 patients treated for non-small-cell lung cancer with 60–66 Gy and dose bins ranging from 2 to 8 Gy in 2 Gy increments. RP prediction models were developed with the least absolute shrinkage and selection operator (LASSO) through fivefold cross-validation. Results: Among the 152 patients in the patient cohort, 41 presented ≥grade 2 RP. The interdependencies between cDVH features evaluated by Spearman’s correlation were significantly resolved by the inclusion of dDVH features. The average area under curve for the RP prediction model using cDVH and dDVH model was 0.73, which was higher than the average area under curve using cDVH model for 0.62 with statistically significance (p < 0.01). An analysis using the entire set of regression coefficients determined by LASSO demonstrated that dDVH features represented four of the top five frequently selected features in the model fitting, regardless of dose bin. Conclusions: We successfully developed an RP prediction model that integrated cDVH and dDVH features. The best RP prediction model was achieved using dDVH (dose bin = 4 Gy) features in the machine learning process.
- 1 January 2022
- Published by Elsevier in Physica Medica
- Vol. 93, 46-51
Evaluation of the electron transport algorithm in magnetic field in EGS5 Monte Carlo code
- 1 January 2022
- Published by Elsevier in Physica Medica
- Vol. 93, 46-51
Evaluation of the electron transport algorithm in magnetic field in EGS5 Monte Carlo code
- Open Access
- 1 January 2020
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 15 (2) , 19-00480
Development of a three-dimensional direct current electric field stimulation bioreactor to enhance the axonal outgrowth and control the axonal orientation
Until now, numerous studies on the effects of electrical stimulation on nerve cell activation in a cell culture have been conducted. However, there are very few studies that have used the three-dimensional (3D) culture system to investigate nerve cell axonal extension. In this study, we developed a novel 3D direct current electric field (DCEF) stimulation bioreactor, which can uniformly stimulate cultured nerve cells for a long period. We observed the morphogenesis of PC12 cells using a multi photon excitation fluorescence microscope (MPM) and evaluated DCEF stimulation effects on PC12 cells axonal outgrowth. First, a DCEF stimulation bioreactor was designed using finite element analysis for uniform electric field. We, then, validated the uniform stimulation of PC12 cells using this bioreactor for 24 h. Second, we determined the optimal stimulation condition using the response surface method and adopting objective functions, such as axonal length, the ratio of axonal orientation towards the anode, and design parameters, such as the electric field strength and the duration of the stimulation. We found the optimal condition to be 43 mV/mm and 6.2 h/day for axonal length enhancement. An increase of 20.1% against the condition for the control group (Mann-Whitney’s U test, p<0.05) was obtained. In addition, the 92 % of PC12 cells were oriented toward the anode with 90 mV/mm, 24 h/day condition. However, the axonal formation was suppressed depending on the stimulation duration. Finally, we found the optimal conditions of 70 mV/mm and 7.9 h/day for achieving the enhancement of axonal extension and orientation, simultaneously.
- 1 January 2020
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 15 (2) , 19-00480
Open AccessDevelopment of a three-dimensional direct current electric field stimulation bioreactor to enhance the axonal outgrowth and control the axonal orientation
Until now, numerous studies on the effects of electrical stimulation on nerve cell activation in a cell culture have been conducted. However, there are very few studies that have used the three-dimensional (3D) culture system to investigate nerve cell axonal extension. In this study, we developed a novel 3D direct current electric field (DCEF) stimulation bioreactor, which can uniformly stimulate cultured nerve cells for a long period. We observed the morphogenesis of PC12 cells using a multi photon excitation fluorescence microscope (MPM) and evaluated DCEF stimulation effects on PC12 cells axonal outgrowth. First, a DCEF stimulation bioreactor was designed using finite element analysis for uniform electric field. We, then, validated the uniform stimulation of PC12 cells using this bioreactor for 24 h. Second, we determined the optimal stimulation condition using the response surface method and adopting objective functions, such as axonal length, the ratio of axonal orientation towards the anode, and design parameters, such as the electric field strength and the duration of the stimulation. We found the optimal condition to be 43 mV/mm and 6.2 h/day for axonal length enhancement. An increase of 20.1% against the condition for the control group (Mann-Whitney’s U test, p<0.05) was obtained. In addition, the 92 % of PC12 cells were oriented toward the anode with 90 mV/mm, 24 h/day condition. However, the axonal formation was suppressed depending on the stimulation duration. Finally, we found the optimal conditions of 70 mV/mm and 7.9 h/day for achieving the enhancement of axonal extension and orientation, simultaneously.