AC flashover performance of various types of insulators under fan-shaped non-uniform pollution
Authors:
- 5 August 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 23 (3) , 1760-1768
Abstract
Previous simulation and observations showed that, the air flow field at windward and leeward side of insulator string will probably be different if the wind velocity is over a certain value, and thus causing the imparity of contamination degree at the two sides. In this paper, fan-shaped non-uniform polluting method was used to artificially simulate the different pollution severity at windward and leeward side of insulator string. Then, the effects of fan-shaped non-uniform pollution on ac flashover performance of 5 types of insulators were discussed. Test results indicate that, SDD, the ratio SDD of windward to leeward side (W/L), the occupation ratio of leeward side (k), will affect the ac flashover performance of insulator string. U50 and SDD still can be expressed by the negative power function. A reduction in W/L from 1/1 to 1/15 would give a decrease about 23% in a value, which causes U50 reducing about 25%, but n value changes little. The correction method proposed by EPRI is also applicable for fan-shaped non-uniform pollution, but has difference. A larger creepage distance of insulator does not mean that the creepage distance utilization rate is higher. Due to the influence of fan-shaped non-uniform pollution, the existing insulation configuration of transmission lines in heavily polluted areas may not satisfy the required insulation margin. The results have certain reference significance for the design and selection of transmission line external insulation.Keywords
This publication has 18 references indexed in Scilit:
- Study on natural contamination performance of typical types of insulatorsIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Pollution accumulation on rail insulator in high-speed aerosolIEEE Transactions on Dielectrics and Electrical Insulation, 2013
- Study on AC Flashover Performance for Different Types of Porcelain and Glass Insulators With Non-Uniform PollutionIEEE Transactions on Power Delivery, 2013
- Effect of non-uniform pollution on the withstand characteristics of extra high voltage (EHV) suspension ceramic insulator stringIET Generation, Transmission & Distribution, 2010
- Investigation of flashover voltage and non-uniform pollution correction coefficient of short samples of composite insulator intended for ±800kV UHVDCIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- Insulator Selection for AC Overhead Lines With Respect to ContaminationIEEE Transactions on Power Delivery, 2009
- Contamination accumulation and withstand voltage characteristics of various types of insulators2004
- Effect of altitude on the flashover voltage of contaminated insulators2002
- Effect of insulator profiles on DC flashover voltage under polluted conditions. A study using a dynamic arc modelIEEE Transactions on Dielectrics and Electrical Insulation, 1994
- Power frequency and impulse field calculation around a HV insulator with uniform or nonuniform surface pollutionIEEE Transactions on Electrical Insulation, 1993