Abstract
This article presents a new power converter capable of direct 48-V/1-V dc–dc conversion with high efficiency. The proposed three-path four-state (3P4S) hybrid switching power stage enables high switching frequency ( $f_{\mathrm {SW}}$ ) operation and minimizes power passives by significantly reducing power switch voltage stress. To address the issues of power delivery path imbalances and potential device breakdown, an adaptive flying capacitor voltage ( $V_{\mathrm {CF}}$ ) rebalancing technique is introduced that improves design robustness and eliminates the need for direct floating $V_{\mathrm {CF}}$ sensing. Additionally, a dual-edge deadtime ( $t_{\mathrm {dead}}$ ) modulation with elastic $t_{\mathrm {dead}}$ control at switching nodes optimizes converter efficiency across different input voltage and load conditions. An IC prototype of the design was fabricated and tested with input voltage $V_{\mathrm {IN}}$ ranging from 12 to 48 V, delivering up to 4 W of power at 1-V $V_{\mathrm {O}}$ . It achieves peak efficiency of 90.7% and 85.6% for 12-V/1-V and 48-V/1-V power conversion, respectively, at an effective switching frequency of 4.5 MHz, which is based on a three-phase operation with each phase at 1.5 MHz. The adaptive $V_{\mathrm {CF}}$ rebalancing technique reduces $V_{\mathrm {CF}}$ imbalance error by up to 65.1%. Overall, the proposed 3P4S hybrid switching power converter offers an efficient and robust solution for direct dc–dc conversion with a wide $V_{\mathrm {IN}}$ range.
Funding Information
  • Texas Instruments

This publication has 13 references indexed in Scilit: