Radiation protection for surgeons and anesthetists: practices and knowledge before and after training
- 8 January 2018
- journal article
- research article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 38 (1) , 175-188
Abstract
The use of radiological activity in the operating room (OR) and a regulatory decrease of the eye lens dose warrant an assessment of how medical staff are protected from radiation. This study aims to evaluate practices and knowledge in radiation protection (RP) for OR doctors before and after training. A descriptive study of surgeons and anesthetists in a French public hospital center was conducted in 2016. An ad hoc questionnaire concerning occupational practices and knowledge about RP was distributed before and one month after RP training. Among 103 doctors attending the training, 90 answered the questionnaire before the training. Results showed a lack of knowledge and good practice in RP. Most of the participants (86.7%) had never been trained in RP and recognized insufficient knowledge. Most of them (92.2%) wore a lead apron, 50.0% a thyroid-shield, 5.6% lead glasses, 53.3% a passive dosimeter and 17.8% an electronic dosimeter. None of them benefitted from collective protective equipment such as a ceiling suspended screen. The questionnaire following the training was completed by only 35 doctors. A comparison before and after training results showed an improvement in knowledge (scores of correct responses: 5.5/16 before and 9.5/16 after training) but not in RP good practices (scores of correct responses: 3.2/7 before and 3.3/7 after training). One training session appears to be insufficient to improve the application of the safety rules when x-rays are used. Communication needs to be improved regarding RP among anesthetists and surgeons, such as training renewal, workstation analysis in OR related to x-ray use and occupational medical follow-up. Otherwise, radiological risks in OR need to be given better consideration, such as radio-induced cataract risk. It is necessary to encourage the use of dosimeters and protective equipment and to strengthen access to lead glasses and collective protective equipment, such as ceiling suspended screens. All these recommendations ensure the received dose is reduced to as low as is reasonably achievable.Keywords
This publication has 26 references indexed in Scilit:
- Public Health England survey of eye lens doses in the UK medical sectorJournal of Radiological Protection, 2013
- Interventional cardiologists and risk of radiation-induced cataract: Results of a French multicenter observational studyInternational Journal of Cardiology, 2013
- Leaded Eyeglasses Substantially Reduce Radiation Exposure of the Surgeon’s Eyes During Acquisition of Typical Fluoroscopic Views of the Hip and PelvisJournal of Bone and Joint Surgery, 2013
- Knowledge and Attitude of European Urology Residents About Ionizing RadiationUrology, 2013
- Knowledge of medical imaging radiation dose and risk among doctorsJournal of Medical Imaging and Radiation Oncology, 2012
- Connaissances en matière de radioprotection : enquête auprès des personnels des services hôspitaliers de radiodiagnostic, radiothérapie et médecine nucléaire a Yaoundé CamerounRadioprotection, 2012
- Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort studyThe Lancet, 2012
- Évaluation des connaissances des prescripteurs de scanner en matière de radioprotection des patientsJournal de Radiologie, 2011
- L’exposition aux radiations ionisantes dans la neurochirurgie rachidienne en 2009Neurochirurgie, 2009
- RXP-WS-4 De la radioprotection en reanimation adulte en 2007Journal de Radiologie, 2008