Change of exposure time mid-test in high temperature DIC measurement
Authors:
Open Access
- 27 April 2020
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (7) , 075402
Abstract
Performing digital image correlation (DIC) at extreme temperatures has been greatly challenging due to the radiation which saturates the camera sensor. At such high temperatures, the light intensity emitted from an object is occasionally so powerful that the acquired images are overwhelmingly saturated. This induces data loss, potentially ruining the test, thus requiring the user to restart the test. For this reason, selection of an appropriate camera sensitivity plays a crucial role prior to beginning the test. Exposure time is a factor contributing to camera sensitivity and it is the easiest setting to manipulate during the test since it introduces minimal errors when comparing to other factors, especially in quasi-static tests. This paper examines the influence of changing exposure time mid-test on DIC measurement uncertainty. The investigation was conducted by rigid body motion experiments at room temperature and 1600 °C, respectively. Thereby, some recommendations are given to help DIC users assess their images at room temperature to extrapolate the exposure at extreme temperatures along with accompanying solutions to salvage data at high temperature.Keywords
Funding Information
- Marshall Space Flight Center (80MSFC18M0009)
This publication has 19 references indexed in Scilit:
- Full-field wing deformation measurement scheme for in-flight cantilever monoplane based on 3D digital image correlationMeasurement Science and Technology, 2014
- Ultraviolet digital image correlation (UV-DIC) for high temperature applicationsReview of Scientific Instruments, 2014
- Calibration: A good calibration imageExperimental Techniques, 2013
- Stereo-rig Design: Lighting-Part 5Experimental Techniques, 2013
- High temperature displacement and strain measurement using a monochromatic light illuminated stereo digital image correlation systemMeasurement Science and Technology, 2012
- High-temperature materials testing with full-field strain measurement: Experimental design and practiceReview of Scientific Instruments, 2011
- High-temperature digital image correlation method for full-field deformation measurement at 1200 °CMeasurement Science and Technology, 2010
- High-temperature strain field measurement using digital image correlationThe Journal of Strain Analysis for Engineering Design, 2009
- Two-dimensional digital image correlation for in-plane displacement and strain measurement: a reviewMeasurement Science and Technology, 2009
- Digital image correlation of nanoscale deformation fields for local stress measurement in thin filmsNanotechnology, 2006