Abstract
Accurate wound area measurement is essential for effective wound care as it helps determine the progression of healing in patients. The aim of this study was to compare two wound area measurement techniques wound tracing (manual planimetry) and imitoMeasure (smartphone-based digital planimetry) with standard ImageJ-based digital image analysis in a rabbit wound healing study. The study involved 291 wounds categorized into small, intermediate, and large wounds. ImageJ was used as the reference method for comparisons. The intraclass correlation coefficient (ICC) was computed to assess the agreement and reliability between different wound measurement techniques. A mountain plot was used to assess the agreement between measurement methods, and a Bland-Altman plot was used to evaluate the agreement and concordance between measurement methods. The time required for analysis (processing time) was also compared. The study revealed that the imitoMeasure consistently demonstrated a greater level of agreement with ImageJ, especially in small and intermediate wounds. The ICC values indicated substantial agreement between ImageJ and imitoMeasure, with an exceptionally high ICC value for small wounds. Mountain plots revealed that the imitoMeasure had better agreement with ImageJ across all wound sizes. Bland-Altman plots further supported these findings, with wound tracing exhibiting wider limits of agreement and greater variability than imitoMeasure. ImitoMeasure consistently proved to be the quickest method across all wound sizes, whereas wound tracing required the longest processing time. These findings indicate that the imitoMeasure is a more reliable and consistent method for measuring the wound area, in particular for small and intermediate wounds.Keywords
This publication has 34 references indexed in Scilit:
- StatPearls2023
- Point-of-care wound visioning technology: Reproducibility and accuracy of a wound measurement appPLOS ONE, 2017
- Simulated Wound Assessment Using Digital Planimetry versus Three-Dimensional Cameras: Implications for Clinical AssessmentAnnals of Vascular Surgery, 2017
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Wound Area Measurement with Digital Planimetry: Improved Accuracy and Precision with Calibration Based on 2 RulersPLOS ONE, 2015
- Methods to assess area and volume of wounds – a systematic reviewInternational Wound Journal, 2015
- Understanding Bland Altman analysisBiochemia Medica, 2015
- A New Smartphone-Based Method for Wound Area MeasurementArtificial Organs, 2013
- Sample size formulas for estimating intraclass correlation coefficients with precision and assuranceStatistics in Medicine, 2012
- A simple, graphical method to evaluate laboratory assays.1995