APAmar Pal

Amar Pal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Amar Pal has a total of 96 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparative biomechanical study of a novel variable diameter circular external fixation device ( VDCF ) for stabilizing a simulated tibial fracture gap in bovine cadaver specimens

    by Rohit Kumar, T. Sai Kumar, K. S. Kamalesh Kumar, Abhishek C. Saxena, Aman Kumar Tiwari, Abhijit Pawde, Amarpal, Rekha Pathak, O. R. Vinodh Kumar

    Objective: To compare the biomechanical performance of a novel variable diameter circular external fixation device (VDCF) with a conventional circular external fixator (CEF) using a standardized osteotomized buffalo tibia model under axial compression and torsional loading. Study design: Experimental in vitro biomechanical comparative study. Sample population: A total of 36 adult bovine tibiae obtained postmortem from buffaloes. Methods: The tibiae were randomly allocated into three groups ( n = 12 each): VDCF, CEF, and intact bone. A standardized mid‐diaphyseal transverse osteotomy with a 20 mm gap was created to simulate an unstable fracture model. Constructs were subjected to axial compression and torsional testing to failure using displacement‐controlled protocols. Key biomechanical parameters evaluated included failure load, axial stiffness, and maximum torque derived from load–deformation curves. Statistical analysis was performed using one‐way ANOVA followed by Tukey's HSD test. Results: Intact tibiae demonstrated significantly greater failure load and axial stiffness than both fixation constructs ( p < .05). No significant differences were detected between VDCF and CEF in failure load or axial stiffness ( p > .05). During torsional testing, maximum torque did not differ significantly between constructs ( p > .05); however, VDCF exhibited significantly greater torsional stiffness than CEF ( p < .05). Failure modes were primarily characterized by plastic deformation and wire bending in both constructs, while fixation‐bolt loosening was observed only in the CEF group. Conclusion: The VDCF showed no significant differences compared with conventional circular external fixation in failure load, axial stiffness, maximum torque, and torsional strength, while exhibiting significantly greater torsional stiffness under the experimental conditions. Clinical significance/impact: The VDCF represents a potential alternative fixation configuration with practical advantages in construct adaptability and cost for fracture stabilization in large animals.

  • Biomechanical evaluation of cemented femoral stem constructs with single and double cerclage stabilization of proximal fissures in canine cadaveric femora

    by K. S. Kamalesh Kumar, Rohit Kumar, T. Sai Kumar, Aman Kumar Tiwari, Abhishek C. Saxena, O. R. Vinodh Kumar, Abhijit Pawde, Amarpal

  • Radiographic Morphometry of the Proximal Femur and Hip Joint in Spitz Breed Dogs: Establishing Breed‐Specific Reference Values

    by K. S. Kamalesh Kumar, Rohit Kumar, T. Sai Kumar, Aman Kumar Tiwari, Bhanu Pratap Singh, Abhishek C. Saxena, Abhijit Pawde, Rekha Pathak, Amarpal

    Variations in hip joint morphology are clinically important because they influence both the diagnosis of orthopaedic disease and the success of surgical interventions. Establishing breed‐ and gender‐specific reference values is therefore essential for understanding normal canine hip anatomy and its variations. The present study aimed to provide radiographic morphometric reference data for the proximal femur and acetabulum in healthy Spitz breed dogs. Sixty adult dogs (30 males, 30 females) underwent standardised ventrodorsal extended hip radiographs under general anaesthesia. Acetabular and femoral morphological parameters were measured, and mean ± SD values were compared between genders and between left and right sides. Most parameters showed no significant differences across groups; however, femoral length, femoral neck length, and right‐sided acetabular offset differed significantly between genders. Combined acetabular parameters (depth index, centre‐edge angle) also showed gender‐specific variation, whereas combined femoral parameters did not. These results provide the first comprehensive radiographic morphometric dataset for the Spitz breed and demonstrate subtle gender‐related differences with minimal left–right asymmetry. We hypothesise that these reference values will support future comparative morphometric studies and contribute to preclinical orthopaedic research, while offering a foundation for the potential development of breed‐specific surgical planning tools.

  • Optimizing canine cemented total hip replacement: technical accuracy and learning outcomes in a cadaver model

    by K. S. Kamalesh Kumar, Rohit Kumar, T. Sai Kumar, Abhishek Chandra Saxena, Abhijit Pawde, Amarpal, R. Prarthana, O. R. Vinodh Kumar

    Total hip arthroplasty effectively restores near-normal gait in most dogs with hip dysplasia unresponsive to conservative treatment. Total hip replacement (THR) requires high surgical accuracy for all surgeons, though errors and deviations are more common during the learning phase (Hayes et al. Vet Surg 40(1):1–5, 2011a). This study aimed to evaluate the technical performance and identify common intraoperative deviations in cemented THR performed by a novice surgeon using canine cadavers. Twelve adult cadavers underwent unilateral THR following a standardized protocol, with implant sizes determined through both radiographic and CT-based preoperative templating. All procedures were performed under expert supervision, with intraoperative corrections made when necessary. Postoperative radiographs were obtained not to detect missed errors but to objectively quantify final implant orientation after correction, thereby documenting technical inaccuracies, including those corrected intraoperatively. Postoperative radiographs were assessed for acetabular cup orientation, femoral stem alignment, canal fill, cement mantle quality, tip-to-cortex distance and cement quality. Overall, > 80% agreement was noted between templated and implanted components. A statistically significant association (p = 0.04) was observed between the matched acetabular cup and femoral stem. While implant positioning, including stem orientation, canal fill, and cement mantle thickness, cementation quality was within acceptable limits, increased canal fill correlated with mild varus or valgus deviations (r = 0.702, p = 0.01). These findings suggest that novice surgeons may achieve reproducible and acceptable outcomes through cadaver-based training with structured mentoring. However, optimal implant placement was not consistently achieved, indicating that further refinement is needed. Larger-scale cadaveric studies and more intensive surgical training protocols are recommended to enhance accuracy, reduce variability, and improve learning outcomes clinically in canine THR.

  • Open Access

    Comparative assessment of smartphone‐based digital planimetry for wound area measurement

    by Sharun Khan, Shajahan A. Banu, Merlin Mamachan, Obli R. Vinodhkumar, Kallemuchikal M. Manjusha, Rohit Kumar, Abhijit M. Pawde, Kuldeep Dhama, Amar Pal

    Accurate wound area measurement is essential for effective wound care as it helps determine the progression of healing in patients. The aim of this study was to compare two wound area measurement techniques wound tracing (manual planimetry) and imitoMeasure (smartphone-based digital planimetry) with standard ImageJ-based digital image analysis in a rabbit wound healing study. The study involved 291 wounds categorized into small, intermediate, and large wounds. ImageJ was used as the reference method for comparisons. The intraclass correlation coefficient (ICC) was computed to assess the agreement and reliability between different wound measurement techniques. A mountain plot was used to assess the agreement between measurement methods, and a Bland-Altman plot was used to evaluate the agreement and concordance between measurement methods. The time required for analysis (processing time) was also compared. The study revealed that the imitoMeasure consistently demonstrated a greater level of agreement with ImageJ, especially in small and intermediate wounds. The ICC values indicated substantial agreement between ImageJ and imitoMeasure, with an exceptionally high ICC value for small wounds. Mountain plots revealed that the imitoMeasure had better agreement with ImageJ across all wound sizes. Bland-Altman plots further supported these findings, with wound tracing exhibiting wider limits of agreement and greater variability than imitoMeasure. ImitoMeasure consistently proved to be the quickest method across all wound sizes, whereas wound tracing required the longest processing time. These findings indicate that the imitoMeasure is a more reliable and consistent method for measuring the wound area, in particular for small and intermediate wounds.


  • Open Access

    ChatGPT and artificial hallucinations in stem cell research: assessing the accuracy of generated references – a preliminary study

    by Khan Sharun, S. Amitha Banu, Abhijit M. Pawde, Rohit Kumar, Shopnil Akash, Kuldeep Dhama, Amar Pal

    Stem cell research has the transformative potential to revolutionize medicine. Language models like ChatGPT, which use artificial intelligence (AI) and natural language processing, generate human-like text that can aid researchers. However, it is vital to ensure the accuracy and reliability of AI-generated references. This study assesses Chat Generative Pre-Trained Transformer (ChatGPT)’s utility in stem cell research and evaluates the accuracy of its references. Of the 86 references analyzed, 15.12% were fabricated and 9.30% were erroneous. These errors were due to limitations such as no real-time internet access and reliance on preexisting data. Artificial hallucinations were also observed, where the text seems plausible but deviates from fact. Monitoring, diverse training, and expanding knowledge cut-off can help to reduce fabricated references and hallucinations. Researchers must verify references and consider the limitations of AI models. Further research is needed to enhance the accuracy of such language models. Despite these challenges, ChatGPT has the potential to be a valuable tool for stem cell research. It can help researchers to stay up-to-date on the latest developments in the field and to find relevant information.


  • Open Access

    Pluronic F-127 Hydrogel for Delivering Antimicrobial Agents: A Bibliometric Analysis using Scopus Database

    by Khan Sharun, S. Amitha Banu, Sonu S. Nair, Rohit Kumar, A.M. Pawde, Kuldeep Dhama, Amar Pal

    Infectious diseases caused by pathogenic microorganisms pose significant threats to public health globally. The emergence of antibiotic-resistant bacteria has further complicated the treatment of these infections, necessitating the exploration of alternative therapeutic strategies. Among these strategies, the use of hydrogels as delivery systems for delivering antimicrobial agents has gained considerable attention. This paper presents a comprehensive bibliometric analysis of the utilization of Pluronic F-127 (PF-127) hydrogel for delivering antimicrobial agents. The aim of this study is to explore the current research landscape, identify key trends, influential authors, and prominent journals in this field. The analysis is based on a systematic search conducted using the Scopus database. The analysis covered publication trends, geographic distribution, influential authors, and key journals in the field of PF-127 hydrogel-based antimicrobial agent delivery. The results revealed the growing interest in this field, with a focus on countries such as India, the United States, and Egypt. The analysis also identified top authors, institutions, and journals contributing to the research. The findings reveal the growth of research in this area, highlighting the potential of PF-127 hydrogel as a promising vehicle for antimicrobial agent delivery. It highlights the need for further research to optimize formulation parameters, explore combination therapies, conduct in vivo studies, and promote collaboration to maximize the therapeutic potential of PF-127 hydrogel-based delivery systems in combating infectious diseases and antimicrobial resistance. This paper provides valuable insights into the existing literature and serves as a reference for future research and development in the field.


  • Open Access

    In vitro Antimicrobial Properties of Pluronic F-127 Injectable Thermoresponsive Hydrogel

    by Khan Sharun, Sonu S. Nair, S. Amitha Banu, K.M. Manjusha, Varsha Jayakumar, Shubham Saini, Abhijit M. Pawde, Rohit Kumar, Kuldeep Dhama, Amar Pal

    Pluronic F-127 (PF-127) hydrogel is a versatile biomaterial with promising applications in drug delivery, tissue engineering, and regenerative medicine. PF-127 has antiadhesive activity that prevents bacterial adhesion by creating a hydrated layer on the bacterial surface. This property makes PF-127 suitable for preventing implant-associated infections. In this study, we aimed to evaluate the antibacterial properties of PF-127 using field isolates of Staphylococcus aureus (Gram-positive bacteria) and Escherichia coli (Gram-negative bacteria) and compare them with different antibiotic standards. The antimicrobial potential was assessed using disk diffusion assays with four standard concentrations (20%, 25%, 30%, and 40%). The test microorganisms were inoculated on agar plates, and sterile filter paper disks infused with PF-127 hydrogels were placed alongside standard antibiotic disks. After incubation, the inhibition zones were measured to determine antimicrobial activity. Our results showed that PF-127 lacked intrinsic antimicrobial activity against S. aureus and E. coli at the tested concentrations. In conclusion, PF-127 hydrogel is a promising neutral carrier hydrogel system for loading antibiotics and antimicrobial compounds. Its unique properties, such as biocompatibility and thermo-responsive behaviour, combined with its antiadhesive activity, make it an ideal candidate for various biomedical applications.


  • Allogenic bone marrow-derived mesenchymal stem cells and its conditioned media for repairing acute and sub-acute peripheral nerve injuries in a rabbit model

    by T.B. Sivanarayanan, Irfan Ahmad Bhat, Khan Sharun, Sangeetha Palakkara, Rashmi Singh, Remya, Mehtab Singh Parmar, Rahul Bhardwaj, Vikash Chandra, Palanivelu Munuswamy, et al.


  • Evaluation of dexmedetomidine with and without butorphanol in tiletamine-zolazepam anesthetized dogs for ovariohysterectomy

    by K.M. Manjusha, P. Kinjavdekar, Amarpal, Rohit Kumar, Khan Sharun, Islam, Aakanksha, A.M. Pawde, A.C. Saxena, U.K. De

    The objective of the study was to evaluate dexmedetomidine with and without butorphanol in tiletamine-zolazepam anaesthesia in dogs for ovariohysterectomy under isoflurane anaesthesia. Twelve healthy adult female dogs of different breeds and age were randomly divided into two groups, with six animals each. All the dogs were administered with atropine sulphate intramuscularly. After 5 min. each dog received either intramuscular dexmedetomidine (10 mcg/kg, DEX) alone or dexmedetomidine (10 mcg/kg) with butorphanol (0.2 mg/kg, DEX-BUT). Once the animal attained a recumbent position, the anaesthesia was induced with tiletamine-zolazepam (TZ) administered intravenously till effect. The anaesthesia was maintained with isoflurane (ISO) for performing elective ovariohysterectomy in all the animals. The combination of DEX with BUT produced more consistent and deep sedation, analgesia, and muscle relaxation than DEX alone. The combination had minimum effect on cardiopulmonary, haemodynamic, and blood biochemical parameters and may be used for performing ovariohysterectomy in dogs.