A Velostat-Based Pressure-Sensitive Mat for Center-of-Pressure Measurements: A Preliminary Study
Open Access
- 2 June 2021
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (11) , 5958
Abstract
Center-of-pressure (CoP) displacements play a key role in studies assessing postural stability. The accepted instrument to measure CoP trajectories is the force platform, but pressure-sensitive mats (PSMs) are an alternative composed of a matrix of sensitive cells. A typical cell comprises two electrodes with piezoresistive material in between, while a force platform has a force sensor at each of its corners. In this paper, we compare a homemade Velostat-based PSM and an affordable commercial mat with a commercial force platform in a test series with 42 healthy volunteers in single-legged trials (29 males, 13 females; height 1.74 (0.09) m, weight 74.3 (16.34) kg, age 31.21 (12.66) years). The aim of the research was to perform a preliminary study of the performance of our prototype to measure CoP, and more specifically, the standard deviation of the CoP path on both axes, the medial–lateral and anterior–posterior. We could thus discover several improvements for future clinical applications. The intraclass correlation coefficient (ICC) for agreement in the base experiment showed a moderate value for the prototype (0.38 to 0.63) and lower values for the commercial mat (0.11 to 0.12). However, we identified several factors that were relevant to improve ICC and reduce error by considering several processing options: (i) the known crosstalk problem between cells that appears in this kind of mats must be eliminated; (ii) the response time of the sensor has to be taken into account; and (iii) increasing the mat resolution also improves agreement. Therefore, as future work, we plan to test the improved version of the prototype in a clinical environment.Keywords
Funding Information
- Ministerio de Ciencia, Innovación y Universidades (FPU-18/04282)
- Instituto de Salud Carlos III, Spanish Government / European Regional Development Fund, A way to build Europe (FIS PI17/00465)
- "Fondo Social Europeo (Programa Operativo FEDER 2014-2020 Construyendo Europa desde Aragón)” / “Diputación General de Aragón” (T49_20R)
This publication has 29 references indexed in Scilit:
- Centre of pressure displacements produced in sitting during virtual reality training in younger and older adults and patients who have had a strokeDisability and Rehabilitation: Assistive Technology, 2019
- Validation Of The Tekscan Strideway Plantar Pressure Mat Compared To A Force PlatformMedicine & Science in Sports & Exercise, 2019
- Comparison of simultaneous static standing balance data on a pressure mat and force plate in typical children and in children with cerebral palsyGait & Posture, 2019
- Validating Center-of-Pressure Balance Measurements Using the MatScan® Pressure MatJournal of Sport Rehabilitation, 2018
- Postural stability analysis — A review of techniques and methods for human stability assessment2017
- Reliability and validity of center of pressure measures for balance assessment in older adultsJournal of Physical Therapy Science, 2016
- Functional reach test: Movement strategies in diabetic subjectsGait & Posture, 2014
- Relationship Between Dynamic Balance Measures and Functional Performance in Community-Dwelling Elderly PeoplePhysical Therapy, 2010
- Infants Born Preterm Exhibit Different Patterns of Center-of-Pressure Movement Than Infants Born at Full TermPhysical Therapy, 2009
- Force Platform Balance Measures as Predictors of Indoor and Outdoor Falls in Community-Dwelling Women Aged 63-76 YearsThe Journals of Gerontology, Series A: Biological Sciences and Medical Sciences, 2008