Abstract
To improve the vibration performance of dual three-phase permanent magnet synchronous motor (PMSM) drives under open-phase fault conditions, a fault-tolerant control strategy with low-vibration performance is proposed in this article. The virtual healthy model, where the control structure and mathematical model remain unchanged under open-phase fault conditions, is adopted in the proposed method. The undisturbed fault-tolerant performance can be obtained. To further suppress the vibration due to the carrier frequency harmonics without compromising the fault-tolerant performance, the hybrid modulation is proposed. The space vector pulsewidth modulation (SVPWM) with the frequency-doubled effect is constructed, where the frequency of harmonics is twice the carrier frequency. The hybrid modulation is achieved by randomly selecting the traditional SVPWM and frequency-doubled SVPWM while maintaining the fixed carrier period and sampling period. Hence, the torque and current performance can hardly be deteriorated. The vibration can be reduced due to the dispersion of high-frequency harmonics. The amplitude of high-frequency current harmonics and vibration is reduced by about 50%. Experimental results are presented to verify the proposed method.
Funding Information
  • National Natural Science Foundation of China (52025073, 52107047)

This publication has 28 references indexed in Scilit: