Tao Tao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tao Tao has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Wenxiang Zhao
Nanjing Institute of Technology
25 shared publications - Chen Wang
School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China
7 shared publications - Yuxuan Du
School of Automation, Nanjing Institute of Technology, Nanjing, China
6 shared publications - Jinghua Ji
Jiangsu University
5 shared publications - Sen Liu
School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China
5 shared publications - Xinxing Zhang
Center of Foundation Engineering Training, Jiangsu University, Zhenjiang, China
4 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 19197-19213
Open-Leg Fault-Tolerant Control for Loop-Winding Five-Phase PMSMs With Symmetric Leg Currents and Improved Torque Capacity
Five-phase permanent magnet synchronous motors (PMSMs) with loop-winding topology exhibit good fault-tolerant capability under an open-leg fault condition. However, unbalanced leg currents increase the risk of subsequent inverter failures. This paper proposes an open-leg fault-tolerant control strategy for loop-winding five-phase PMSMs, aiming to optimize leg currents and achieve symmetric inverter operation. First, the phase currents are directly reconstructed in the original coordinate system to address the asymmetric winding connection after an open-leg fault, facilitating the establishment of the relationship between magnetomotive force and leg currents. Then, the optimized phase and leg currents are proposed using a geometric approach under symmetric leg-current constraints. To extend the applicability of the proposed method, a unified fault-tolerant switching table is designed for addressing arbitrary single-leg open-circuit faults. Finally, the influence of the third-order back-EMF on the torque and leg currents is analyzed and compensated, extending the applicability to non-sinusoidal five-phase PMSMs. Compared with the existing method, the proposed method can effectively reduce the maximum leg currents and indirectly enhance the output torque capacity. Experimental results demonstrate the effectiveness and feasibility of the proposed method.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 19197-19213
Open-Leg Fault-Tolerant Control for Loop-Winding Five-Phase PMSMs With Symmetric Leg Currents and Improved Torque Capacity
Five-phase permanent magnet synchronous motors (PMSMs) with loop-winding topology exhibit good fault-tolerant capability under an open-leg fault condition. However, unbalanced leg currents increase the risk of subsequent inverter failures. This paper proposes an open-leg fault-tolerant control strategy for loop-winding five-phase PMSMs, aiming to optimize leg currents and achieve symmetric inverter operation. First, the phase currents are directly reconstructed in the original coordinate system to address the asymmetric winding connection after an open-leg fault, facilitating the establishment of the relationship between magnetomotive force and leg currents. Then, the optimized phase and leg currents are proposed using a geometric approach under symmetric leg-current constraints. To extend the applicability of the proposed method, a unified fault-tolerant switching table is designed for addressing arbitrary single-leg open-circuit faults. Finally, the influence of the third-order back-EMF on the torque and leg currents is analyzed and compensated, extending the applicability to non-sinusoidal five-phase PMSMs. Compared with the existing method, the proposed method can effectively reduce the maximum leg currents and indirectly enhance the output torque capacity. Experimental results demonstrate the effectiveness and feasibility of the proposed method.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (7) , 10779-10790
Enhanced Fault-Tolerant Control for Torque Ripple Reduction in Dual Three-Phase PMSMs Considering Back EMF Harmonics
With fault-tolerant operation of dual three-phase permanent magnet synchronous machine (DTP-PMSM), the torque ripple deteriorated by back electromotive force (EMF) harmonics is harmful for high precision servo control field in aviation. This article proposes an open-circuit fault-tolerant control strategy to optimize the torque ripple caused by back EMF harmonics. Firstly, the mechanism of torque ripple deterioration is investigated by using magnetomotive force synthesis theory. Then, harmonic components of torque ripples are analytically derived based on the back EMF harmonic distribution. Subsequently, the fault-tolerant current references are newly deduced for both isolated and single neutral point winding configurations by using the torque ripple optimization algorithm. However, for the single neutral point configuration, the copper loss is greatly increased when using the optimized fault tolerant current references. Therefore, a trade-off point is established to balance torque ripples and copper loss. The proposed strategy effectively suppresses torque ripple within a compact framework and demonstrates high practical feasibility. Finally, the effectiveness and superiority of proposed strategy is verified through experimental results on a 48-slot and 22-pole DTP-PMSM.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (7) , 10779-10790
Enhanced Fault-Tolerant Control for Torque Ripple Reduction in Dual Three-Phase PMSMs Considering Back EMF Harmonics
With fault-tolerant operation of dual three-phase permanent magnet synchronous machine (DTP-PMSM), the torque ripple deteriorated by back electromotive force (EMF) harmonics is harmful for high precision servo control field in aviation. This article proposes an open-circuit fault-tolerant control strategy to optimize the torque ripple caused by back EMF harmonics. Firstly, the mechanism of torque ripple deterioration is investigated by using magnetomotive force synthesis theory. Then, harmonic components of torque ripples are analytically derived based on the back EMF harmonic distribution. Subsequently, the fault-tolerant current references are newly deduced for both isolated and single neutral point winding configurations by using the torque ripple optimization algorithm. However, for the single neutral point configuration, the copper loss is greatly increased when using the optimized fault tolerant current references. Therefore, a trade-off point is established to balance torque ripples and copper loss. The proposed strategy effectively suppresses torque ripple within a compact framework and demonstrates high practical feasibility. Finally, the effectiveness and superiority of proposed strategy is verified through experimental results on a 48-slot and 22-pole DTP-PMSM.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (7) , 10791-10804
High-Frequency Harmonic and Vibration Suppression for PM Machine With Improved Random Number Properties
Random switching frequency space vector pulse width modulation (RSF-SVPWM) strategy mitigates high-frequency harmonics and vibrations by randomly varying the switching frequency across a specified frequency range. However, its effectiveness in suppressing high-frequency harmonics and vibrations is constrained. This paper introduces an enhanced RSF-SVPWM strategy through improving random number properties. Specifically, the Beta distribution and random number constraints are employed in a cascaded manner. The Beta distribution improves the probability density of the random numbers, while the random number constraint reduces the average relative changes between adjacent switching frequencies, leading to more effective suppression of high-frequency harmonics and vibrations. Moreover, the torque ripple and current distortion are not adversely affected by the frequency randomization in RSF-SVPWM. Experimental results validate the effectiveness of the proposed method.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (7) , 10791-10804
High-Frequency Harmonic and Vibration Suppression for PM Machine With Improved Random Number Properties
Random switching frequency space vector pulse width modulation (RSF-SVPWM) strategy mitigates high-frequency harmonics and vibrations by randomly varying the switching frequency across a specified frequency range. However, its effectiveness in suppressing high-frequency harmonics and vibrations is constrained. This paper introduces an enhanced RSF-SVPWM strategy through improving random number properties. Specifically, the Beta distribution and random number constraints are employed in a cascaded manner. The Beta distribution improves the probability density of the random numbers, while the random number constraint reduces the average relative changes between adjacent switching frequencies, leading to more effective suppression of high-frequency harmonics and vibrations. Moreover, the torque ripple and current distortion are not adversely affected by the frequency randomization in RSF-SVPWM. Experimental results validate the effectiveness of the proposed method.
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 14915-14926
Resilient Current Sampling Method With Fault-Tolerant Capability for Dual Three-Phase PMSM
In the dual three-phase permanent magnet synchronous motor (DTP-PMSM) drive, the loss of current information will lead to degradation of control performance. This paper proposes a resilient current sampling method to ensure fault-tolerant operation even after the failure of four current sensors. First, the prerequisites for complete phase current acquisition are derived in a DTP-PMSM drive system. Then, the resilient current sampling method with multiple sampling paths per phase current is proposed. Furthermore, the feasibility of the proposed method to maintain continuous operation is verified by these prerequisites under various current sensor faults. With the proposed resilient current sampling method, the lost current information caused by the fault is recovered, ensuring the high performance of the motor. Finally, experimental results validate the proposed resilient sampling method.
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 14915-14926
Resilient Current Sampling Method With Fault-Tolerant Capability for Dual Three-Phase PMSM
In the dual three-phase permanent magnet synchronous motor (DTP-PMSM) drive, the loss of current information will lead to degradation of control performance. This paper proposes a resilient current sampling method to ensure fault-tolerant operation even after the failure of four current sensors. First, the prerequisites for complete phase current acquisition are derived in a DTP-PMSM drive system. Then, the resilient current sampling method with multiple sampling paths per phase current is proposed. Furthermore, the feasibility of the proposed method to maintain continuous operation is verified by these prerequisites under various current sensor faults. With the proposed resilient current sampling method, the lost current information caused by the fault is recovered, ensuring the high performance of the motor. Finally, experimental results validate the proposed resilient sampling method.
- 10 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 3472-3488
Enhanced Fault-Tolerant Control of Current Sensors Using Orthogonal Current Sampling Strategy for Dual Three-Phase PMSM Drives
Focusing on current sensor fault scenarios in dual three-phase permanent magnet synchronous motor (DTP-PMSM) drives, this article develops a fault-tolerant control scheme with an optimized current sampling architecture. First, to ensure the feasibility of stable motor operation, the required minimum number of current samples is analyzed. Then, the errors of phase current estimation under different distributions are compared. Building on these insights, an orthogonal current sampling strategy is proposed to enhance fault-tolerant control capability. For the scenarios with broken-line fault and stuck fault, the motor can operate with a single normal current sensor. Gain fault is inherently mitigated without algorithmic intervention. Zero-offset fault can be suppressed through different sampled fusion. The proposed fault-tolerant control algorithm avoids the use of observers and is independent of motor parameters. Experimental validation confirms the efficacy of the proposed fault-tolerant control framework, showing sustained motor stability across multiple fault scenarios.
- 10 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 3472-3488
Enhanced Fault-Tolerant Control of Current Sensors Using Orthogonal Current Sampling Strategy for Dual Three-Phase PMSM Drives
Focusing on current sensor fault scenarios in dual three-phase permanent magnet synchronous motor (DTP-PMSM) drives, this article develops a fault-tolerant control scheme with an optimized current sampling architecture. First, to ensure the feasibility of stable motor operation, the required minimum number of current samples is analyzed. Then, the errors of phase current estimation under different distributions are compared. Building on these insights, an orthogonal current sampling strategy is proposed to enhance fault-tolerant control capability. For the scenarios with broken-line fault and stuck fault, the motor can operate with a single normal current sensor. Gain fault is inherently mitigated without algorithmic intervention. Zero-offset fault can be suppressed through different sampled fusion. The proposed fault-tolerant control algorithm avoids the use of observers and is independent of motor parameters. Experimental validation confirms the efficacy of the proposed fault-tolerant control framework, showing sustained motor stability across multiple fault scenarios.
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 4552-4562
Carrier Phase Shift Control to Reduce Iron Loss in Nine-Phase Cobalt–Iron PMSMs
Cobalt–iron multiphase permanent magnet synchronous motors (PMSMs) exhibit superior electromagnetic performance but induce elevated iron loss, especially under high-modulation index condition. This article investigates a carrier phase shift-based control scheme for nine-phase cobalt–iron PMSMs in order to mitigate high-frequency harmonic currents and reduce iron loss. First, the effect of high-frequency harmonic currents on iron loss is systematically analyzed under varied conditions. Afterward, the first-, second-, third-, and fourth-sideband harmonic currents are derived with varying modulation index. Under high-modulation index condition, the first-sideband harmonic currents, which have much larger amplitude than the second, third, and fourth, are found to play a critical role in reducing iron loss. Subsequently, a targeted sideband harmonic currents cancelation method is developed. Theoretical analysis identifies an optimal 8$\boldsymbol{\pi}$/9 carrier phase shift between three modules for mitigating the first-sideband harmonic currents. Therefore, the iron loss under high-modulation index can be reduced effectively. Finally, experimental results verify that the proposed control scheme can achieve high-frequency harmonic currents mitigation and iron loss reduction.
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 4552-4562
Carrier Phase Shift Control to Reduce Iron Loss in Nine-Phase Cobalt–Iron PMSMs
Cobalt–iron multiphase permanent magnet synchronous motors (PMSMs) exhibit superior electromagnetic performance but induce elevated iron loss, especially under high-modulation index condition. This article investigates a carrier phase shift-based control scheme for nine-phase cobalt–iron PMSMs in order to mitigate high-frequency harmonic currents and reduce iron loss. First, the effect of high-frequency harmonic currents on iron loss is systematically analyzed under varied conditions. Afterward, the first-, second-, third-, and fourth-sideband harmonic currents are derived with varying modulation index. Under high-modulation index condition, the first-sideband harmonic currents, which have much larger amplitude than the second, third, and fourth, are found to play a critical role in reducing iron loss. Subsequently, a targeted sideband harmonic currents cancelation method is developed. Theoretical analysis identifies an optimal 8$\boldsymbol{\pi}$/9 carrier phase shift between three modules for mitigating the first-sideband harmonic currents. Therefore, the iron loss under high-modulation index can be reduced effectively. Finally, experimental results verify that the proposed control scheme can achieve high-frequency harmonic currents mitigation and iron loss reduction.
- 5 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (2) , 1083-1095
Maximum Torque per Ampere-Based Direct Torque Control of Five-Phase Permanent Magnet Synchronous Motor Under Open-Circuit Fault
Conventional direct torque control (DTC) with constant reference stator flux leads to inefficiency in permanent magnet synchronous motors (PMSMs), since the optimal reference stator flux varies with load conditions and non-optimal values result in larger currents. This paper proposes a novel DTC strategy based on virtual square-wave injection (VSWI-DTC) to achieve maximum-torque-per-ampere (MTPA) operation and maintain high dynamic performance of five-phase PMSM under open-circuit fault. The novelty lies in detecting the optimal stator flux through virtual square-wave injection into the m-axis flux, integrated with a fault-tolerant transformation matrix to achieve enhanced MTPA-based DTC. Unified decoupled models are derived in the stator-flux reference frame for both healthy and fault conditions, in which the m-axis flux equals the stator flux amplitude. Based on the derived relationship between stator current and flux, the optimal m-axis flux is obtained online under varying operating conditions. Synergized with deadbeat-based DTC, the proposed strategy minimizes copper loss, enhances efficiency, and suppresses torque fluctuations caused by open-circuit fault. Furthermore, since no filters are required, the fast dynamic response of DTC is preserved. Experimental results validate the effectiveness of the proposed strategy.
- 5 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (2) , 1083-1095
Maximum Torque per Ampere-Based Direct Torque Control of Five-Phase Permanent Magnet Synchronous Motor Under Open-Circuit Fault
Conventional direct torque control (DTC) with constant reference stator flux leads to inefficiency in permanent magnet synchronous motors (PMSMs), since the optimal reference stator flux varies with load conditions and non-optimal values result in larger currents. This paper proposes a novel DTC strategy based on virtual square-wave injection (VSWI-DTC) to achieve maximum-torque-per-ampere (MTPA) operation and maintain high dynamic performance of five-phase PMSM under open-circuit fault. The novelty lies in detecting the optimal stator flux through virtual square-wave injection into the m-axis flux, integrated with a fault-tolerant transformation matrix to achieve enhanced MTPA-based DTC. Unified decoupled models are derived in the stator-flux reference frame for both healthy and fault conditions, in which the m-axis flux equals the stator flux amplitude. Based on the derived relationship between stator current and flux, the optimal m-axis flux is obtained online under varying operating conditions. Synergized with deadbeat-based DTC, the proposed strategy minimizes copper loss, enhances efficiency, and suppresses torque fluctuations caused by open-circuit fault. Furthermore, since no filters are required, the fast dynamic response of DTC is preserved. Experimental results validate the effectiveness of the proposed strategy.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (6) , 12911-12923
Low-Vibration Fault-Tolerant Control for Dual Three-Phase PMSM Using Hybrid Modulation With Fixed Carrier Frequency
To improve the vibration performance of dual three-phase permanent magnet synchronous motor (PMSM) drives under open-phase fault conditions, a fault-tolerant control strategy with low-vibration performance is proposed in this article. The virtual healthy model, where the control structure and mathematical model remain unchanged under open-phase fault conditions, is adopted in the proposed method. The undisturbed fault-tolerant performance can be obtained. To further suppress the vibration due to the carrier frequency harmonics without compromising the fault-tolerant performance, the hybrid modulation is proposed. The space vector pulsewidth modulation (SVPWM) with the frequency-doubled effect is constructed, where the frequency of harmonics is twice the carrier frequency. The hybrid modulation is achieved by randomly selecting the traditional SVPWM and frequency-doubled SVPWM while maintaining the fixed carrier period and sampling period. Hence, the torque and current performance can hardly be deteriorated. The vibration can be reduced due to the dispersion of high-frequency harmonics. The amplitude of high-frequency current harmonics and vibration is reduced by about 50%. Experimental results are presented to verify the proposed method.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (6) , 12911-12923
Low-Vibration Fault-Tolerant Control for Dual Three-Phase PMSM Using Hybrid Modulation With Fixed Carrier Frequency
To improve the vibration performance of dual three-phase permanent magnet synchronous motor (PMSM) drives under open-phase fault conditions, a fault-tolerant control strategy with low-vibration performance is proposed in this article. The virtual healthy model, where the control structure and mathematical model remain unchanged under open-phase fault conditions, is adopted in the proposed method. The undisturbed fault-tolerant performance can be obtained. To further suppress the vibration due to the carrier frequency harmonics without compromising the fault-tolerant performance, the hybrid modulation is proposed. The space vector pulsewidth modulation (SVPWM) with the frequency-doubled effect is constructed, where the frequency of harmonics is twice the carrier frequency. The hybrid modulation is achieved by randomly selecting the traditional SVPWM and frequency-doubled SVPWM while maintaining the fixed carrier period and sampling period. Hence, the torque and current performance can hardly be deteriorated. The vibration can be reduced due to the dispersion of high-frequency harmonics. The amplitude of high-frequency current harmonics and vibration is reduced by about 50%. Experimental results are presented to verify the proposed method.