Abstract
Objective. Urodynamic studies (UDSs) are vital for evaluating bladder function but require invasive catheterization to measure detrusor pressure ( P det ). Our purpose is to report on technical developments toward a noninvasive and accurate estimation of P det through ultrasound (US), a technique we refer to as US-UDS. Approach. The proposed US-UDS technique produces an estimate of P det by using US to induce and track elastic waves that propagate within and around the bladder wall. Key components of the US-UDS processing include: an US sequence with dense time sampling; an empirical correction accounting for deviation from a Lamb wave dispersion model; and constrained optimization for P det estimation. US-UDS analysis for estimation of P det was applied to 533 distinct data points collected from 3 human subjects undergoing concurrent UDS. Concordance analysis was used to evaluate agreement between US-UDS and UDS measures of P det while response operator characteristic analysis was used to evaluate US-UDS for detection of detrusor activity (parameterized as UDS P det >15 cmH 2 O). Main results. US-UDS was able estimate P det within 10 cmH 2 O and 5 cmH 2 O of UDS measurements with coverage probabilities of 95.7% and 68.8% respectively. Furthermore, US-UDS was able to detect UDS P det measurements greater than 15 cmH 2 O with a sensitivities and specificities of 0.99 and 0.83 using a fixed threshold (>15 cmH 2 O for US-UDS) and 1.0 and 0.93 for an optimized threshold (> 11.08 cmH 2 O for US-UDS). Significance. Our results show that the technical developments of US-UDS put forth in this work are able produce accurate and useful estimates of P det as compared to traditional UDS. Although additional research with a large number of subjects is needed to fully characterize the clinical utility of US-UDS, the developments and results from this work demonstrate that clinically useful non-invasive measurements of P det are feasible from US measurements.Keywords
Funding Information
- National Institute of Health (R01DK131685)
This publication has 61 references indexed in Scilit:
- Efficacy and safety of mirabegron in children and adolescents with neurogenic detrusor overactivity: An open‐label, phase 3, dose‐titration studyNeurourology and Urodynamics, 2021
- What developments are needed to achieve less‐invasive urodynamics? ICI‐RS 2019Neurourology and Urodynamics, 2020
- Effects of bladder shape on accuracy of measurement of bladder volume using portable ultrasound scanner and development of correction methodNeurourology and Urodynamics, 2019
- Measuring Intraventricular Pressure Using Ultrasound ElastographyJournal of Ultrasound in Medicine, 2018
- International continence society guidelines on urodynamic equipment performanceNeurourology and Urodynamics, 2014
- Defining achievable standards in urodynamics—a prospective study of initial resting pressuresNeurourology and Urodynamics, 2012
- Good urodynamic practices: Uroflowmetry, filling cystometry, and pressure‐flow studies**Neurourology and Urodynamics, 2002
- Involuntary detrusor contractions: correlation of urodynamic data to clinical categories.Neurourology and Urodynamics, 2001
- Variability of pressure-flow studies in men with lower urinary tract symptomsNeurourology and Urodynamics, 2000
- Index for rating diagnostic testsCancer, 1950