Inverter-Embedded Detection of Rotor Winding Faults in Doubly Fed Induction Generators for Wind Energy Applications
- 8 September 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (1) , 646-652
Abstract
Automated and remote testing of wind turbines is highly desirable since they are prone to failure with the harsh operating environment, and are difficult to test due to the remote location and limited accessibility. The turn insulation of the rotor winding is susceptible to failure due to operating stresses. Unlike turn faults in the stator, rotor turn faults do not cause immediate failure due to the low induced voltage in the shorted loop at low slip frequency, and therefore, are difficult to detect during operation. Although this fault progresses slowly, it must be detected to prevent performance degradation due to rotor asymmetry. In this article, a new concept for inverter-embedded testing of doubly fed induction generators (DFIG) used for wind energy applications is presented. The main idea is to inject test voltages into the DFIG rotor winding from the rotor side inverter whenever the wind turbine is stopped, to extract information on the rotor asymmetry. The proposed test concept is a simple off-line test that can be implemented in DFIGs without additional hardware to perform automated and sensitive detection of rotor faults. Experimental results show that faults in the rotor winding can be detected with higher sensitivity compared to on-line methods for improving the reliability of wind turbines.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2019R1A2C1084104)
This publication has 25 references indexed in Scilit:
- Impact of rotor inter-turn short circuit fault upon performance of a wound rotor induction motor2015
- Reliability Comparison of Wind Turbines With DFIG and PMG Drive TrainsIEEE Transactions on Energy Conversion, 2014
- Detection of rotor electrical asymmetry in wind turbine doubly‐fed induction generatorsIET Renewable Power Generation, 2014
- Detecting Faults in Doubly Fed Induction Generator by Rotor Side Transient Current MeasurementIEEE Transactions on Industry Applications, 2014
- Diagnosis of Rotor and Stator Asymmetries in Wound-Rotor Induction Machines Under Nonstationary Operation Through the Instantaneous FrequencyIEEE Transactions on Industrial Electronics, 2013
- Offshore Wind Power Generation TechnologiesProceedings of the IEEE, 2013
- Condition Monitoring of the Power Output of Wind Turbine Generators Using WaveletsIEEE Transactions on Energy Conversion, 2010
- Assessment of Condition Monitoring Techniques for Offshore Wind FarmsJournal of Solar Energy Engineering, 2008
- Survey of Failures in Wind Power Systems With Focus on Swedish Wind Power Plants During 1997–2005IEEE Transactions on Energy Conversion, 2007
- Enhancement of Damage-Detection of Wind Turbine Blades Via CWT-Based ApproachesIEEE Transactions on Energy Conversion, 2006