Muhammad Faizan Shaikh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Muhammad Faizan Shaikh has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Sang Bin Lee
Department of Electrical Engineering Korea, University Seoul, Seoul, South Korea
21 shared publications - Byambasuren Battulga
Department of Electrical Engineering, Korea University, Seoul, Korea
6 shared publications - Han-Ju Kim
Department of Electrical Engineering, Korea University, Seoul, South Korea
6 shared publications Byambasuren Battulga
Underground Electrical and Instrumentation Department, Oyu Tolgoi Ulaanbaatar, Mongolia
5 shared publications- Carlos Antonio Platero
Automatic Electric and Electronic Engineering and Industrial Computing Department, Universidad Politcnica de Madrid, Madrid, Spain
5 shared publications Mohamed Osama
GE Aerospace Munich, Germany
4 shared publications
Latest Publications
- 9 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 277-286
Automated Inverter-Embedded Testing of Step-Up Transformers in Renewable Energy Systems
Transformers are employed in renewable energy systems such as wind and solar power generation for stepping up the voltage supplied to the grid. They are known to have higher failure rates compared to grid transformers, as they are exposed to a hostile environment and fluctuating operating conditions. However, testing relies on on-site tests, which are costly to perform as they are installed in remote locations that are difficult to access. In this paper, a new approach for transformer testing using the inverter available in the system, is proposed. The main idea is to use the inverter as the test equipment for injecting test signals into the transformer low voltage (LV) winding to obtain the frequency response of admittance for detecting faults whenever the renewable energy system is de-energized. An equivalent circuit analysis is given to show that defects in the core, winding, insulation, and LCL filter can be detected from the change in admittance over a wide frequency range, similar to frequency response analysis (FRA) commonly used for transformer testing. Experimental test results of the proposed method and FRA performed on a 380/690V, 15 kVA, 3 phase transformer are given under emulated core insulation failure, insulation contamination, and poor electrical contacts for validation.
- 9 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 277-286
Automated Inverter-Embedded Testing of Step-Up Transformers in Renewable Energy Systems
Transformers are employed in renewable energy systems such as wind and solar power generation for stepping up the voltage supplied to the grid. They are known to have higher failure rates compared to grid transformers, as they are exposed to a hostile environment and fluctuating operating conditions. However, testing relies on on-site tests, which are costly to perform as they are installed in remote locations that are difficult to access. In this paper, a new approach for transformer testing using the inverter available in the system, is proposed. The main idea is to use the inverter as the test equipment for injecting test signals into the transformer low voltage (LV) winding to obtain the frequency response of admittance for detecting faults whenever the renewable energy system is de-energized. An equivalent circuit analysis is given to show that defects in the core, winding, insulation, and LCL filter can be detected from the change in admittance over a wide frequency range, similar to frequency response analysis (FRA) commonly used for transformer testing. Experimental test results of the proposed method and FRA performed on a 380/690V, 15 kVA, 3 phase transformer are given under emulated core insulation failure, insulation contamination, and poor electrical contacts for validation.
- 28 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 9139-9147
Automated Testing of Rotor Faults in Wound Field Synchronous Motors for EV Applications
Wound field synchronous motors (WFSM) are being considered as a viable alternative to permanent magnet synchronous motors (PMSM) by leading electric vehicle (EV) manufacturers. With WFSMs, the risk related to the instability of rare-earth PM supply can be averted, and it is possible to improve the motor performance across a wide operating range with flexible control of the rotor field. However, reliability concerns arise from harsh operating conditions with fluctuating load and speed. Given the historical predominance of PMSMs in EVs, industry lacks experience with WFSM rotor testing and failure analysis. In this paper, a new concept for automated detection of WFSM rotor faults such as field winding turn faults and eccentricity is proposed. The main idea is to use the dc-dc converter available for field control, as the test equipment for detecting rotor faults, whenever the EV is stopped. The change in the field winding impedance under optimal excitation conditions is used for detection and classification of field winding turn faults and eccentricity. An experimental study on 20 and 30 kVA WFSMs shows that the proposed method can provide automated detection and classification of WFSM rotor faults using existing hardware.
- 28 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 9139-9147
Automated Testing of Rotor Faults in Wound Field Synchronous Motors for EV Applications
Wound field synchronous motors (WFSM) are being considered as a viable alternative to permanent magnet synchronous motors (PMSM) by leading electric vehicle (EV) manufacturers. With WFSMs, the risk related to the instability of rare-earth PM supply can be averted, and it is possible to improve the motor performance across a wide operating range with flexible control of the rotor field. However, reliability concerns arise from harsh operating conditions with fluctuating load and speed. Given the historical predominance of PMSMs in EVs, industry lacks experience with WFSM rotor testing and failure analysis. In this paper, a new concept for automated detection of WFSM rotor faults such as field winding turn faults and eccentricity is proposed. The main idea is to use the dc-dc converter available for field control, as the test equipment for detecting rotor faults, whenever the EV is stopped. The change in the field winding impedance under optimal excitation conditions is used for detection and classification of field winding turn faults and eccentricity. An experimental study on 20 and 30 kVA WFSMs shows that the proposed method can provide automated detection and classification of WFSM rotor faults using existing hardware.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 6994-7003
Vibration-Based Detection and Classification of Mechanical Defects in Induction Motor-Driven Systems During the Starting Transient
Vibration analysis is considered the most common and effective means of detecting mechanical faults such as imbalance, misalignment, and looseness in induction motor driven systems. Most mechanical problems result in an increase in vibration at multiples of the rotor speed frequency (1x) making it difficult to discern the source of vibration. In case of a fault alarm, the maintenance engineer usually performs a walk-around test to identify the source of vibration for planning maintenance, and therefore, is exposed to safety risks. In this paper, a new remote and automated test method for identifying the source of mechanical vibration during the starting transient of induction motors is proposed. The level and speed-dependency of vibration during rotor acceleration are used for identifying imbalance from other mechanical defects that produce 1x vibration. Test results on a 380 V, 5.5 kW induction motor under mechanical defects are given for verification. It is shown that the proposed method can provide automated identification of the source of vibration enabling maintenance to be performed in a safe, low cost, and efficient manner. The data acquired and analyzed for the testing are described and shared through this paper.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 6994-7003
Vibration-Based Detection and Classification of Mechanical Defects in Induction Motor-Driven Systems During the Starting Transient
Vibration analysis is considered the most common and effective means of detecting mechanical faults such as imbalance, misalignment, and looseness in induction motor driven systems. Most mechanical problems result in an increase in vibration at multiples of the rotor speed frequency (1x) making it difficult to discern the source of vibration. In case of a fault alarm, the maintenance engineer usually performs a walk-around test to identify the source of vibration for planning maintenance, and therefore, is exposed to safety risks. In this paper, a new remote and automated test method for identifying the source of mechanical vibration during the starting transient of induction motors is proposed. The level and speed-dependency of vibration during rotor acceleration are used for identifying imbalance from other mechanical defects that produce 1x vibration. Test results on a 380 V, 5.5 kW induction motor under mechanical defects are given for verification. It is shown that the proposed method can provide automated identification of the source of vibration enabling maintenance to be performed in a safe, low cost, and efficient manner. The data acquired and analyzed for the testing are described and shared through this paper.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-9
Remote and Automated Insulation Testing for VFD-Driven Motor Systems With High Resistance Grounding
The failure rate of motor insulation in variable frequency drive (VFD) motors is higher compared to that of mains-fed motors due to the increased electrical stresses inflicted by the VFD. At present, motor insulation testing in industry relies on offline testing at the motor terminals, which requires physical access to the de-energized motor. Considering the increased likelihood of failure and difficulty of off-line testing, remote and automated testing is desirable, as VFD motors become prevalent. A new concept for testing the ground insulation of VFD motors that leverages high-resistance ground systems is presented in this article. The main concept is to apply the insulation test voltage using the VFD and measure the leakage current from the grounding resistor with high resolution. The capacitance (C) and dissipation factor (DF) are calculated and trended over time to identify ground insulation degradation before failure occurs. This test can be embedded in the VFD and performed automatically without motor access or disassembly whenever the motor is stopped. Test methods for assessing the insulation condition of the ac grid-, dc bus-, and motor-side of the VFD system are proposed and verified experimentally.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-9
Remote and Automated Insulation Testing for VFD-Driven Motor Systems With High Resistance Grounding
The failure rate of motor insulation in variable frequency drive (VFD) motors is higher compared to that of mains-fed motors due to the increased electrical stresses inflicted by the VFD. At present, motor insulation testing in industry relies on offline testing at the motor terminals, which requires physical access to the de-energized motor. Considering the increased likelihood of failure and difficulty of off-line testing, remote and automated testing is desirable, as VFD motors become prevalent. A new concept for testing the ground insulation of VFD motors that leverages high-resistance ground systems is presented in this article. The main concept is to apply the insulation test voltage using the VFD and measure the leakage current from the grounding resistor with high resolution. The capacitance (C) and dissipation factor (DF) are calculated and trended over time to identify ground insulation degradation before failure occurs. This test can be embedded in the VFD and performed automatically without motor access or disassembly whenever the motor is stopped. Test methods for assessing the insulation condition of the ac grid-, dc bus-, and motor-side of the VFD system are proposed and verified experimentally.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1686-1689
Sensitive Detection of Shorted Field Winding Turns in Salient Pole Synchronous Machines With High Frequency Pole Drop Test
The pole drop test is the most widely accepted test for detecting short circuits in the field winding of salient pole synchronous machines (SPSM). Although it is a simple and effective test, there are concerns on the reliability due to the inherent asymmetry between the poles, especially for cases where the percentage of shorted turns is low. Considering that this is the primary test used in industry for detecting shorted field turns in SPSMs, improving the sensitivity of the test is highly desirable for reliable fault detection. In this paper, it is shown that the sensitivity of the pole drop test can be significantly improved by increasing the excitation frequency of the test voltage above the 50/60 Hz currently used, which is not reported elsewhere. An electrical equivalent circuit analysis and an experimental study on a 4 pole, 30 kVA synchronous motor and a 14 pole, 100 kVA hydrogenator prototype are given to verify the claims made.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1686-1689
Sensitive Detection of Shorted Field Winding Turns in Salient Pole Synchronous Machines With High Frequency Pole Drop Test
The pole drop test is the most widely accepted test for detecting short circuits in the field winding of salient pole synchronous machines (SPSM). Although it is a simple and effective test, there are concerns on the reliability due to the inherent asymmetry between the poles, especially for cases where the percentage of shorted turns is low. Considering that this is the primary test used in industry for detecting shorted field turns in SPSMs, improving the sensitivity of the test is highly desirable for reliable fault detection. In this paper, it is shown that the sensitivity of the pole drop test can be significantly improved by increasing the excitation frequency of the test voltage above the 50/60 Hz currently used, which is not reported elsewhere. An electrical equivalent circuit analysis and an experimental study on a 4 pole, 30 kVA synchronous motor and a 14 pole, 100 kVA hydrogenator prototype are given to verify the claims made.
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (1) , 690-693
Frequency Response Analysis for Quality Assurance Testing of Hairpin Stator Winding Insulation for Electric Vehicle Applications
With the rapid growth in electric vehicles (EV), hairpin wound stators are replacing random wound stators due to their higher power density and efficiency, and because of the ease with which manufacturing can be automated at a fast rate. Failure in the EV motor stator insulation is a major concern with increasing electrical stresses due to higher dc link voltage and wide bandgap devices. It is critical to implement a series of fast and effective quality assurance (QA) tests to screen defective units to maintain the quality and reliability, while keeping the production cost of EV motors low. Experience with EV motors showed that poor stator insulation quality is a leading cause of manufacturing defects in hairpin windings. In this work, the feasibility of applying frequency response analysis (FRA) for identifying defective hairpin stator insulation is evaluated. Test results on poorly impregnated EV motors with FRA and 6 common insulation tests show that FRA provides the most effective and reliable assessment of the insulation quality of hairpin wound stators.
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (1) , 690-693
Frequency Response Analysis for Quality Assurance Testing of Hairpin Stator Winding Insulation for Electric Vehicle Applications
With the rapid growth in electric vehicles (EV), hairpin wound stators are replacing random wound stators due to their higher power density and efficiency, and because of the ease with which manufacturing can be automated at a fast rate. Failure in the EV motor stator insulation is a major concern with increasing electrical stresses due to higher dc link voltage and wide bandgap devices. It is critical to implement a series of fast and effective quality assurance (QA) tests to screen defective units to maintain the quality and reliability, while keeping the production cost of EV motors low. Experience with EV motors showed that poor stator insulation quality is a leading cause of manufacturing defects in hairpin windings. In this work, the feasibility of applying frequency response analysis (FRA) for identifying defective hairpin stator insulation is evaluated. Test results on poorly impregnated EV motors with FRA and 6 common insulation tests show that FRA provides the most effective and reliable assessment of the insulation quality of hairpin wound stators.
- 22 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (1) , 41-49
Converter Embedded Testing of Inter-Laminar Core Insulation of Step-Up Transformers for Wind Energy Applications
Transformers used in wind power applications for stepping up the low voltage output of wind generators are known to have high failure rate due to the harsh operating conditions and environment. It is a challenge to perform on-site tests regularly because wind turbines are difficult to access due to their remote location. This makes remote and automated condition assessment of wind turbine transformers (WTT) crucial for preventing failure. In this paper, the feasibility of a new off-line method for testing the quality of the inter-laminar insulation of the step-up transformer core using the back-to-back converter is evaluated. The idea is to use the converter available in the wind turbine as the test equipment for injecting test signals into the WTT for remote and automated testing, whenever the wind turbine is disconnected from the grid. It is shown that inter-laminar core faults can be clearly detected with sensitivity comparable to the core loss test and commercial FRA equipment. An experimental study was performed on a 380/690 V transformer under emulated inter-laminar insulation fault conditions to verify the new test concept. It is shown that the proposed method can provide remote, automated testing of WTTs for reliable detection of core faults.
- 22 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (1) , 41-49
Converter Embedded Testing of Inter-Laminar Core Insulation of Step-Up Transformers for Wind Energy Applications
Transformers used in wind power applications for stepping up the low voltage output of wind generators are known to have high failure rate due to the harsh operating conditions and environment. It is a challenge to perform on-site tests regularly because wind turbines are difficult to access due to their remote location. This makes remote and automated condition assessment of wind turbine transformers (WTT) crucial for preventing failure. In this paper, the feasibility of a new off-line method for testing the quality of the inter-laminar insulation of the step-up transformer core using the back-to-back converter is evaluated. The idea is to use the converter available in the wind turbine as the test equipment for injecting test signals into the WTT for remote and automated testing, whenever the wind turbine is disconnected from the grid. It is shown that inter-laminar core faults can be clearly detected with sensitivity comparable to the core loss test and commercial FRA equipment. An experimental study was performed on a 380/690 V transformer under emulated inter-laminar insulation fault conditions to verify the new test concept. It is shown that the proposed method can provide remote, automated testing of WTTs for reliable detection of core faults.
- 28 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (19) , 31104-31113
MEMS Accelerometer and Hall Sensor-Based Identification of Electrical and Mechanical Defects in Induction Motors and Driven Systems
Early detection of faults in motor driven systems in industrial facilities is critical for maintaining productive, efficient, and safe operation of the plant. The recent trend in condition monitoring of industrial motors is shifting towards installation of compact, low-cost sensors on the motor from which the data is transferred wirelessly to a server for diagnosis. In this work, a cost-effective system and fault identification method based on MEMS capacitive accelerometer and a Hall-effect sensor measurements is presented. A new method for detection and classification of electrical and mechanical defects in the motor, coupling, and load based on spectral analysis of velocity and leakage flux measurements from the motor frame, is proposed. A comparative experimental evaluation of MEMS sensors and conventional piezoelectric accelerometers and search coils is given under rotor cage fault, eccentricity, imbalance, misalignment, bearing defect, and looseness conditions, to show the viability of the proposed fault detection method. It is shown that the proposed system can provide reliable detection and classification of the above-mentioned defects for variable frequency drive (VFD)-fed induction motors. The voltage, current, leakage/ airgap flux, and vibration database acquired from MEMS and conventional sensors under different operating conditions with 6 electrical and mechanical faults are described and shared through this paper.
- 28 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (19) , 31104-31113
MEMS Accelerometer and Hall Sensor-Based Identification of Electrical and Mechanical Defects in Induction Motors and Driven Systems
Early detection of faults in motor driven systems in industrial facilities is critical for maintaining productive, efficient, and safe operation of the plant. The recent trend in condition monitoring of industrial motors is shifting towards installation of compact, low-cost sensors on the motor from which the data is transferred wirelessly to a server for diagnosis. In this work, a cost-effective system and fault identification method based on MEMS capacitive accelerometer and a Hall-effect sensor measurements is presented. A new method for detection and classification of electrical and mechanical defects in the motor, coupling, and load based on spectral analysis of velocity and leakage flux measurements from the motor frame, is proposed. A comparative experimental evaluation of MEMS sensors and conventional piezoelectric accelerometers and search coils is given under rotor cage fault, eccentricity, imbalance, misalignment, bearing defect, and looseness conditions, to show the viability of the proposed fault detection method. It is shown that the proposed system can provide reliable detection and classification of the above-mentioned defects for variable frequency drive (VFD)-fed induction motors. The voltage, current, leakage/ airgap flux, and vibration database acquired from MEMS and conventional sensors under different operating conditions with 6 electrical and mechanical faults are described and shared through this paper.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5979-5987
Detection of Shorted Turns in the Field Winding of Turbo Generators During Turning Gear Mode
A new off-line test concept for detecting shorted field winding turns in the rotor of synchronous generators, when operated under turning gear mode, is proposed in this paper. Turbo generators are operated in turning gear mode after shutdown and/or before startup, where the rotor is turned at low speed (<50 rpm), to prevent thermal bowing of the turbine and generator rotor. The main idea of the new test method is to detect turn insulation failure in the rotor field winding by observing the pattern of change in the equivalent impedance measured from the stator side, while the rotor is rotated slowly with the turning gear. An equivalent circuit analysis is given to show that the decrease in the equivalent d-axis impedance provides a sensitive indicator of turn faults in the rotor winding. It is shown that the proposed method that has not been attempted elsewhere, is a simple and convenient test for detecting shorted field turns with high sensitivity and reliability compared to the test methods widely applied in the field. The validity of the proposed method is verified with finite element simulation and experimental testing on 4 pole, 20 kVA and 2 pole, 5.5 kVA synchronous machines.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5979-5987
Detection of Shorted Turns in the Field Winding of Turbo Generators During Turning Gear Mode
A new off-line test concept for detecting shorted field winding turns in the rotor of synchronous generators, when operated under turning gear mode, is proposed in this paper. Turbo generators are operated in turning gear mode after shutdown and/or before startup, where the rotor is turned at low speed (<50 rpm), to prevent thermal bowing of the turbine and generator rotor. The main idea of the new test method is to detect turn insulation failure in the rotor field winding by observing the pattern of change in the equivalent impedance measured from the stator side, while the rotor is rotated slowly with the turning gear. An equivalent circuit analysis is given to show that the decrease in the equivalent d-axis impedance provides a sensitive indicator of turn faults in the rotor winding. It is shown that the proposed method that has not been attempted elsewhere, is a simple and convenient test for detecting shorted field turns with high sensitivity and reliability compared to the test methods widely applied in the field. The validity of the proposed method is verified with finite element simulation and experimental testing on 4 pole, 20 kVA and 2 pole, 5.5 kVA synchronous machines.
- 22 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-9
Detection Of Severe Ground Insulation Deterioration Before Failure in VFD-Fed Motors Using Off-line Common-Mode Voltage
Recently, the number of electrical machines operated via inverters has significantly increased. Multiple works have pointed out that insulation aging occurs faster for inverter-fed machines due to voltage overshoots and uneven voltage distribution caused by high dV/dt switching at several kHz. This necessitates better insulation monitoring methods so that deteriorating insulation quality can be detected, before machines fail and the industrial process is interrupted. A good monitoring method is one that achieves a balance between the reliability of detection and cost requirements. Monitoring methods requiring the installation of expensive and intrusive sensors cannot be justified for all machines. Therefore, a new method for the monitoring of ground insulation condition for inverter-fed machines applying common-mode voltage at motor standstill is proposed in this paper. The proposed method utilizes the commonly used sensors usually employed for differential protection and is simple in its application. It can be implemented whenever the motor is off-line for a short period of time and can screen out severe insulation deterioration that could lead to forced outages. The method has been verified experimentally in the lab on two, 380 V, 18.5 kW and 5.5 kW induction machines.
- 22 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-9
Detection Of Severe Ground Insulation Deterioration Before Failure in VFD-Fed Motors Using Off-line Common-Mode Voltage
Recently, the number of electrical machines operated via inverters has significantly increased. Multiple works have pointed out that insulation aging occurs faster for inverter-fed machines due to voltage overshoots and uneven voltage distribution caused by high dV/dt switching at several kHz. This necessitates better insulation monitoring methods so that deteriorating insulation quality can be detected, before machines fail and the industrial process is interrupted. A good monitoring method is one that achieves a balance between the reliability of detection and cost requirements. Monitoring methods requiring the installation of expensive and intrusive sensors cannot be justified for all machines. Therefore, a new method for the monitoring of ground insulation condition for inverter-fed machines applying common-mode voltage at motor standstill is proposed in this paper. The proposed method utilizes the commonly used sensors usually employed for differential protection and is simple in its application. It can be implemented whenever the motor is off-line for a short period of time and can screen out severe insulation deterioration that could lead to forced outages. The method has been verified experimentally in the lab on two, 380 V, 18.5 kW and 5.5 kW induction machines.