Fracture models in the lumbar sheep spine: A biomechanical investigation
- 14 April 2010
- journal article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 28 (6) , 773-777
Abstract
The purpose of this study was to find out if a limited resection of the cranial vertebral body leaving the posterior wall intact is a sufficient model for AO type 3 fractures, or if additional resection of the posterior wall is necessary. In six, fresh‐frozen, lumbar sheep spine specimens, the segmental stability was tested in three motion planes in a spine tester. First, the intact specimens were tested. Then, partial resection of the intervertebral disc L3/4 and resection of the cranial vertebral body of L4 was performed, leaving the posterior wall intact. This defect was tested without instrumentation and with a ventral monosegmental interlocking plate mounted. Then, the defect was extended to a total cranial resection, including the posterior wall, and the tests were subsequently repeated. The stability of both types of defects under the different conditions was compared. Without instrumentation, the total cranial resection showed significantly more ROM in flexion/extension and axial rotation than partial cranial resection. With the ventral interlocking plate mounted, the instability in total cranial resection was significantly higher in flexion/extension, with the relative relation even being increased. In axial rotation and lateral bending, the differences were equalized by the mounted plate. From a biomechanical point of view, total cranial resection including the posterior wall should be preferred as a sheep spine fracture model for AO type 3 fractures. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:773–777, 2010Keywords
This publication has 24 references indexed in Scilit:
- Comparison of open versus percutaneous pedicle screw insertion in a sheep modelEuropean Spine Journal, 2008
- Lumbar interbody expanding cageVeterinary and Comparative Orthopaedics and Traumatology, 2008
- Animal models for spinal researchEuropean Spine Journal, 2007
- Are the spines of calf, pig and sheep suitable models for pre-clinical implant tests?European Spine Journal, 2007
- Evaluation of hydroxyapatite ceramic vertebral spacers with different porosities and their binding capability to the vertebral body: an experimental study in sheepJournal of Neurosurgery: Spine, 2007
- Evaluation of the 96/4 PLDLLA polymer resorbable lumbar interbody cage in a long term animal modelEuropean Spine Journal, 2006
- Endoscopic surgery on the thoracolumbar junction of the spineEuropean Spine Journal, 2006
- Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implantsEuropean Spine Journal, 1998
- Are Sheep Spines a Valid Biomechanical Model for Human Spines?Spine, 1997
- A comprehensive classification of thoracic and lumbar injuriesEuropean Spine Journal, 1994