Jan Heineck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jan Heineck has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Stefan Rammelt
Klinik für Unfall—u. Wiederherstellungschirurgie, Universitätsklinik Carl Gustav Carus der Technischen Universität Dresden, Fetscherstr. 74, 01307 Dresden, Germany
4 shared publicationsCornelius Haupt
Klinik für Unfall—u. Wiederherstellungschirurgie, Universitätsklinik Carl Gustav Carus der Technischen Universität Dresden, Fetscherstr. 74, 01307 Dresden, Germany
3 shared publicationsH. Zwipp
Universitätsklinik
2 shared publicationsR. Grass
Universitätsklinik
2 shared publicationsS. Rammelt
Universitätsklinik
2 shared publicationsWolfgang Schneiders
Klinik für Unfall-u, Wiederherstellungschirurgie, Universitätsklinik Carl Gustav Carus der Technischen Universität Dresden, Dresden, Germany
2 shared publications
Latest Publications
- 14 April 2010
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 28 (6) , 773-777
Fracture models in the lumbar sheep spine: A biomechanical investigation
The purpose of this study was to find out if a limited resection of the cranial vertebral body leaving the posterior wall intact is a sufficient model for AO type 3 fractures, or if additional resection of the posterior wall is necessary. In six, fresh‐frozen, lumbar sheep spine specimens, the segmental stability was tested in three motion planes in a spine tester. First, the intact specimens were tested. Then, partial resection of the intervertebral disc L3/4 and resection of the cranial vertebral body of L4 was performed, leaving the posterior wall intact. This defect was tested without instrumentation and with a ventral monosegmental interlocking plate mounted. Then, the defect was extended to a total cranial resection, including the posterior wall, and the tests were subsequently repeated. The stability of both types of defects under the different conditions was compared. Without instrumentation, the total cranial resection showed significantly more ROM in flexion/extension and axial rotation than partial cranial resection. With the ventral interlocking plate mounted, the instability in total cranial resection was significantly higher in flexion/extension, with the relative relation even being increased. In axial rotation and lateral bending, the differences were equalized by the mounted plate. From a biomechanical point of view, total cranial resection including the posterior wall should be preferred as a sheep spine fracture model for AO type 3 fractures. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:773–777, 2010
- 14 April 2010
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 28 (6) , 773-777
Fracture models in the lumbar sheep spine: A biomechanical investigation
The purpose of this study was to find out if a limited resection of the cranial vertebral body leaving the posterior wall intact is a sufficient model for AO type 3 fractures, or if additional resection of the posterior wall is necessary. In six, fresh‐frozen, lumbar sheep spine specimens, the segmental stability was tested in three motion planes in a spine tester. First, the intact specimens were tested. Then, partial resection of the intervertebral disc L3/4 and resection of the cranial vertebral body of L4 was performed, leaving the posterior wall intact. This defect was tested without instrumentation and with a ventral monosegmental interlocking plate mounted. Then, the defect was extended to a total cranial resection, including the posterior wall, and the tests were subsequently repeated. The stability of both types of defects under the different conditions was compared. Without instrumentation, the total cranial resection showed significantly more ROM in flexion/extension and axial rotation than partial cranial resection. With the ventral interlocking plate mounted, the instability in total cranial resection was significantly higher in flexion/extension, with the relative relation even being increased. In axial rotation and lateral bending, the differences were equalized by the mounted plate. From a biomechanical point of view, total cranial resection including the posterior wall should be preferred as a sheep spine fracture model for AO type 3 fractures. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:773–777, 2010
- 1 August 2009
- Published by SAGE Publications in Foot & Ankle International
- Vol. 30 (8) , 773-777
Accuracy of Corrective Osteotomies in Fibular Malunion: A Cadaver Model
Background: While incorrect length of a fibular fracture reduction can be measured by plain radiographs, accurate imaging of rotational deformities requires computed tomography (CT). Operative correction of fibular malrotation has not been accurately measured. The aim of this study was to evaluate the accuracy of operative correction of fibular malrotation. Materials and Methods: Six pairs of formalin-fixed, lower leg cadaver specimens had shortening with additional internal or external rotation induced by segmental fibular resection and plate fixation. The deformity was measured by CT. Two experienced surgeons performed standardized corrective operations on six specimens each. The postoperative results were measured by CT. Results: The mean overall accuracy for correction of malrotation was 1.58 degrees (SD = 0.8 degrees). There were no significant differences between the two surgeons performing the corrections. Conclusion: The accuracy of operative correction of malrotation in this cadaver model is in accordance with the requirements reported in clinical studies. Clinical Relevance: Considering the error margin for CT analysis, correction within 5 to 10 degrees seems practical.
- 1 August 2009
- Published by SAGE Publications in Foot & Ankle International
- Vol. 30 (8) , 773-777
Accuracy of Corrective Osteotomies in Fibular Malunion: A Cadaver Model
Background: While incorrect length of a fibular fracture reduction can be measured by plain radiographs, accurate imaging of rotational deformities requires computed tomography (CT). Operative correction of fibular malrotation has not been accurately measured. The aim of this study was to evaluate the accuracy of operative correction of fibular malrotation. Materials and Methods: Six pairs of formalin-fixed, lower leg cadaver specimens had shortening with additional internal or external rotation induced by segmental fibular resection and plate fixation. The deformity was measured by CT. Two experienced surgeons performed standardized corrective operations on six specimens each. The postoperative results were measured by CT. Results: The mean overall accuracy for correction of malrotation was 1.58 degrees (SD = 0.8 degrees). There were no significant differences between the two surgeons performing the corrections. Conclusion: The accuracy of operative correction of malrotation in this cadaver model is in accordance with the requirements reported in clinical studies. Clinical Relevance: Considering the error margin for CT analysis, correction within 5 to 10 degrees seems practical.
- Open Access
- 7 February 2009
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 11 (2) , 179-183
Periprothetische kniegelenknahe Fraktur
- 7 February 2009
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 11 (2) , 179-183
Open AccessPeriprothetische kniegelenknahe Fraktur
- 26 September 2008
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 129 (8) , 1089-1092
Fifth metatarsal avulsion fracture: a rational basis for postoperative treatment
Background Lacking rational basis for the postoperative treatment of fifth metatarsal avulsion fractures. Methods Biomechanical test of stability of tension banding and screw fixation of fifth metatarsal avulsion fractures in cadaver specimen, sonographic measuring of the maximum cross-section of the peroneus brevis muscle, electromyographic examinations of the activity of the peroneus brevis muscle at different loads and means of immobilization. Results The forces acting on the base of the fifth metatarsal bone during voluntary activation of the peroneus brevis muscle or activation in the gait cycle are of the same magnitude as the failure forces of internal fixation. Immobilization of the talocrural joint achieves no reduction in muscle activation. Partial weight bearing reduces muscle activation. Conclusions The postoperative treatment after osteosynthesis of fifth metatarsal avulsion fractures should be partial weight bearing. For safety reasons we add an elastic ankle orthesis to prevent supination. A below-knee cast is not necessary.
- 26 September 2008
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 129 (8) , 1089-1092
Fifth metatarsal avulsion fracture: a rational basis for postoperative treatment
Background Lacking rational basis for the postoperative treatment of fifth metatarsal avulsion fractures. Methods Biomechanical test of stability of tension banding and screw fixation of fifth metatarsal avulsion fractures in cadaver specimen, sonographic measuring of the maximum cross-section of the peroneus brevis muscle, electromyographic examinations of the activity of the peroneus brevis muscle at different loads and means of immobilization. Results The forces acting on the base of the fifth metatarsal bone during voluntary activation of the peroneus brevis muscle or activation in the gait cycle are of the same magnitude as the failure forces of internal fixation. Immobilization of the talocrural joint achieves no reduction in muscle activation. Partial weight bearing reduces muscle activation. Conclusions The postoperative treatment after osteosynthesis of fifth metatarsal avulsion fractures should be partial weight bearing. For safety reasons we add an elastic ankle orthesis to prevent supination. A below-knee cast is not necessary.
- Open Access
- 1 January 2008
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 79 (2) , 225-229
Transsection of the rectus abdominis muscle in the treatment of acetabular fractures: Operative technique and outcome in 21 patients
Background A standard ilioinguinal approach is often insufficient for reduction and stabilization of the medial acetabular wall and the dorsal column in acetabular fractures. To avoid extended approaches, we have used a medial extension of the approach by transverse splitting of the rectus abdominis muscle. We have thus been able to reduce and stabilize transverse and oblique fractures of the dorsal column and the medial acetabular wall and to fix plates in a mechanically better position below the pelvic brim. To evaluate the procedure, especially the risk of abdominal hernia, we started a prospective study. Patients and methods Over 2 years, we treated 21 consecutive patients using a transverse splitting of the rectus abdominis muscle—either as an extension of the standard ilioinguinal approach or in combination with parts of this approach or a Kocher-Langenbeck approach. The patients were evaluated clinically and radiographically after 1 year. Results The clinical and radiographic results were excellent or good in 18 patients. Complications occurred in 5 patients. No hernias were observed. Conclusions Our small study indicates that the procedure described is a useful and safe complement to the intrapelvic approaches. The procedure does not provide better reduction than extended approaches, but may help to avoid them in some cases.
- 1 January 2008
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 79 (2) , 225-229
Open AccessTranssection of the rectus abdominis muscle in the treatment of acetabular fractures: Operative technique and outcome in 21 patients
Background A standard ilioinguinal approach is often insufficient for reduction and stabilization of the medial acetabular wall and the dorsal column in acetabular fractures. To avoid extended approaches, we have used a medial extension of the approach by transverse splitting of the rectus abdominis muscle. We have thus been able to reduce and stabilize transverse and oblique fractures of the dorsal column and the medial acetabular wall and to fix plates in a mechanically better position below the pelvic brim. To evaluate the procedure, especially the risk of abdominal hernia, we started a prospective study. Patients and methods Over 2 years, we treated 21 consecutive patients using a transverse splitting of the rectus abdominis muscle—either as an extension of the standard ilioinguinal approach or in combination with parts of this approach or a Kocher-Langenbeck approach. The patients were evaluated clinically and radiographically after 1 year. Results The clinical and radiographic results were excellent or good in 18 patients. Complications occurred in 5 patients. No hernias were observed. Conclusions Our small study indicates that the procedure described is a useful and safe complement to the intrapelvic approaches. The procedure does not provide better reduction than extended approaches, but may help to avoid them in some cases.
- 1 June 2007
- Published by Springer Nature in Der Unfallchirurg
- Vol. 110 (6) , 571-575
Ventral fusion of a fracture of the cervical spine in ankylosing spondylitis and struma permagna
Halswirbelsäulenfrakturen bei Morbus Bechterew sind seltene Verletzungen. Sie sind häufiger mit neurologischen Ausfällen verbunden als Frakturen der gesunden Halswirbelsäule. In Ihren mechanischen Eigenschaften ähnelt die ankylosierte Wirbelsäule einem Röhrenknochen. Konventionelle Orthesen und Lagerungstechniken gewährleisten aufgrund der Deformität und der Einsteifung oft keine ausreichende Ruhigstellung, und es muss improvisiert werden, um eine schonende Bergung und einen schonenden Transport zu ermöglichen. Bei den meist sehr instabilen Verletzungen besteht die Indikation zur Operation. Die stabilste Versorgung gewährleistet die ein- oder zweizeitige dorsoventrale Fusion. Der dorsale Zugang ist allerdings mit einer deutlich höheren Komplikationsrate behaftet, sodass wir die primäre ventrale Stabilisierung mit langstreckigen winkelstabilen Implantaten favorisieren. Diese kann auch bei schwierigen anatomischen Verhältnissen sicher ausgeführt werden. Bei gutem Schraubenhalt kann dann auf eine zusätzliche dorsale Fusion verzichtet werden. Fractures of the cervical spine in ankylosing spondylitis are rare. The rate of neurological complications is increased compared to fractures of the normal spine. Concerning its mechanical characteristics the ankylosing spine is similar to a long bone. Because of the deformity and the stiffness of the spine conventional orthoses do not provide enough stability and individualized techniques are necessary to perform safe rescue and transport. Because of severe instability an operation is indicated in most cases. The most stable fixation is the combined ventral and dorsal fusion. The dorsal approach is associated with an increased rate of complications, so we favour primary ventral fusion with long interlocking plates. This can be done even in difficult anatomic situations. If the screws can be tightened well, additional dorsal fusion is not necessary.
- 1 June 2007
- Published by Springer Nature in Der Unfallchirurg
- Vol. 110 (6) , 571-575
Ventral fusion of a fracture of the cervical spine in ankylosing spondylitis and struma permagna
Halswirbelsäulenfrakturen bei Morbus Bechterew sind seltene Verletzungen. Sie sind häufiger mit neurologischen Ausfällen verbunden als Frakturen der gesunden Halswirbelsäule. In Ihren mechanischen Eigenschaften ähnelt die ankylosierte Wirbelsäule einem Röhrenknochen. Konventionelle Orthesen und Lagerungstechniken gewährleisten aufgrund der Deformität und der Einsteifung oft keine ausreichende Ruhigstellung, und es muss improvisiert werden, um eine schonende Bergung und einen schonenden Transport zu ermöglichen. Bei den meist sehr instabilen Verletzungen besteht die Indikation zur Operation. Die stabilste Versorgung gewährleistet die ein- oder zweizeitige dorsoventrale Fusion. Der dorsale Zugang ist allerdings mit einer deutlich höheren Komplikationsrate behaftet, sodass wir die primäre ventrale Stabilisierung mit langstreckigen winkelstabilen Implantaten favorisieren. Diese kann auch bei schwierigen anatomischen Verhältnissen sicher ausgeführt werden. Bei gutem Schraubenhalt kann dann auf eine zusätzliche dorsale Fusion verzichtet werden. Fractures of the cervical spine in ankylosing spondylitis are rare. The rate of neurological complications is increased compared to fractures of the normal spine. Concerning its mechanical characteristics the ankylosing spine is similar to a long bone. Because of the deformity and the stiffness of the spine conventional orthoses do not provide enough stability and individualized techniques are necessary to perform safe rescue and transport. Because of severe instability an operation is indicated in most cases. The most stable fixation is the combined ventral and dorsal fusion. The dorsal approach is associated with an increased rate of complications, so we favour primary ventral fusion with long interlocking plates. This can be done even in difficult anatomic situations. If the screws can be tightened well, additional dorsal fusion is not necessary.
- 1 May 2006
- Published by Springer Nature in Der Unfallchirurg
- Vol. 109 (5) , 411-416
Traumatische Hemipelvektomie
- 1 May 2006
- Published by Springer Nature in Der Unfallchirurg
- Vol. 109 (5) , 411-416
Traumatische Hemipelvektomie