Comparison of round-window membrane mechanics before and after experimental stapedotomy
- 16 August 2011
- journal article
- research article
- Published by Wiley in The Laryngoscope
- Vol. 121 (9) , 1958-1964
Abstract
Background: Surgical intervention within the area of the middle ear always leads to alteration of conditions in its biomechanical system. This fact may provide an explanation for the lack of expected auditory outcome, although an apparently good anatomic outcome was obtained. In the case of stapedotomy, the majority of patients report lack of satisfactory results for frequencies above 2,000 Hz. The effect has not been experimentally investigated yet. Methods: This study, conducted in four human temporal bones, yielded a record of round‐window membrane vibration amplitude and phase in the frequency function (400 Hz–10 kHz) at the sound intensity level of 90 dB administered to the external auditory canal in a physiologic condition and following implantation of a Teflon piston stapes prosthesis. The procedure of experimental stapedotomy was performed with the tympanic membrane preserved from the maximally dilated approach through the posterior tympanotomy. Results: Stapes Teflon piston prosthesis implantation was found to cause approximately fivefold lower amplitude of round‐window membrane vibrations compared to a physiologic situation for frequencies above 2 kHz in particular. Conclusions: After stapedotomy, with the use of a Teflon piston prosthesis, stimulation of inner ear structures diminishes, especially in higher frequencies.Keywords
This publication has 17 references indexed in Scilit:
- Measurements of Human Middle- and Inner-Ear Mechanics With Dehiscence of the Superior Semicircular CanalOtology & Neurotology, 2007
- Stapedotomy with Microdrill or Carbon Dioxide Laser: Influence on Inner Ear FunctionAnnals of Otology, Rhinology & Laryngology, 2006
- Surgical Findings and Long-Term Hearing Results in 3,050 Stapedotomies for Primary OtosclerosisOtology & Neurotology, 2006
- Middle ear cavity and ear canal pressure-driven stapes velocity responses in human cadaveric temporal bonesThe Journal of the Acoustical Society of America, 2006
- Malleus-to-Footplate versus Malleus-to-Stapes-Head Ossicular Reconstruction Prostheses: Temporal Bone Pressure Gain Measurements and Clinical Audiological DataOtology & Neurotology, 2005
- Experimental ossicular fixations and the middle ear’s response to sound: Evidence for a flexible ossicular chainHearing Research, 2005
- Malleus-to-Footplate Ossicular Reconstruction Prosthesis Positioning: Cochleovestibular Pressure OptimizationOtology & Neurotology, 2005
- Acoustic Role of the Buttress and Posterior Incudal Ligament in Human Temporal BonesOtolaryngology–Head and Neck Surgery, 2001
- The equality of volume displacements in the inner ear windowsThe Journal of the Acoustical Society of America, 1995
- Cadaver Middle Ears as Models for Living Ears: Comparisons of Middle Ear Input ImmittanceAnnals of Otology, Rhinology & Laryngology, 1990