MMMaciej Mrówka

Maciej Mrówka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maciej Mrówka has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Removal of a metallic foreign body from the Eustachian tube by anthromastoidectomy – posterior tympanotomy in a welder with a tumor of the cerebellopontine angle. Case report

    by Anna Piecuch, Maciej Mrówka, Piotr H. Skarżyński, Henryk Skarżyński

    Wstęp: Metaliczne odpryski powstające podczas procesu spawania, osiągające niewielkie rozmiary, dużą prędkość i wysokie temperatury, mogą penetrować do ucha środkowego i trąbki słuchowej.Opis przypadku: Opis przypadku leczenia operacyjnego spawacza leczonego w Światowym Centrum Słuchu Instytutu Fizjologii i Patologii Słuchu w Kajetanach, u którego zaistniała konieczność usunięcia ferromagnetycznego ciała obcego z trąbki słuchowej Eustachiusza ze względu na potrzebę monitorowania guza kąta mostowo-móżdżkowego. Jest to pierwszy w literaturze przedmiotu opis przypadku usuwania u spawacza metalicznego ciała obcego z trąbki słuchowej drogą antromastoidektomii – tympanotomii tylnej.Wnioski: Trudno gojące się, przewlekające zapalenia ucha zewnętrznego lub środkowego oraz przetrwałe perforacje błony bębenkowej u spawacza powinny skłonić do poszukiwania zalegającego ciała obcego w tej lokalizacji. W przypadku penetracji ciała obcego do trąbki słuchowej istnieje możliwość jego usunięcia drogą antromastoidectomii – tympanotomii tylnej. Konieczna jest nieustanna edukacja pacjentów i pracowników odnośnie stosowania środków ochrony osobistej: zabezpieczania uszu za pomocą ochronników słuchu lub zatyczek podczas pracy spawalniczej i obróbki metalu.

  • Open Access

    The Implantable Bone Conduction Devices – operating principles and indications

    by Anna Ratuszniak, Maciej Mrówka, Piotr H. Skarżyński, Henryk Skarżyński

    Zdolność ludzkiego układu słuchowego do odbioru sygnałów akustycznych na drodze przewodnictwa kostnego nabiera specyficznego znaczenia w przypadku wad wrodzonych i nabytych ucha zewnętrznego i środkowego. W obecnym wówczas niedosłuchu typu przewodzeniowego lub mieszanego postępowaniem mogą być różne postaci klasycznej rekonstrukcji układu przewodzącego ucha na drodze chirurgicznej. Kiedy jednak możliwości te zostają wyczerpane lub nie przynoszą zadowalającego efektu słuchowego jedynym sposobem na kompensowanie niedosłuchu pozostaje protezowanie na drodze przewodnictwa powietrznego lub kostnego. W przypadku braku możliwości lub przeciwwskazań do protezownia klasycznego na drodze przewodnictwa powietrznego do rozważenia pozostaje zastosowanie urządzenia wykorzystującego kostne przewodnictwo dźwięków. Niniejsza praca opisuje kostną drogę odbioru dźwięków, wskazania i kryteria kwalifikacji do wszczepienia urządzeń na przewodnictwo kostne oraz przybliża budowę i zasadę działania dostępnych rozwiązań.

  • Open Access

    Novel and De Novo Mutations Extend Association of POU3F4 with Distinct Clinical and Radiological Phenotype of Hearing Loss

    by Agnieszka Pollak, Urszula Lechowicz, Anna Kędra, Piotr Stawiński, Małgorzata Rydzanicz, Mariusz Furmanek, Małgorzata Brzozowska, Maciej Mrówka, Henryk Skarżyński, Piotr H Skarżyński, et al.

    POU3F4 mutations (DFNX2) are the most prevalent among non-syndromic X-linked hearing loss (HL) identified to date. Clinical manifestations of DFNX2 usually comprise congenital HL either sensorineural or mixed, a tendency towards perilymphatic gusher during otologic surgery and temporal bone malformations. The aim of the present study was to screen for POU3F4 mutations in a group of 30 subjects with a suggestive clinical phenotype as well as a group (N = 1671–2018) of unselected hearing loss patients. We also planned to analyze audiological and radiological features in patients with HL caused by POU3F4 defects. The molecular techniques used to detect POU3F4 mutations included whole exome sequencing (WES), Sanger sequencing and real-time polymerase chain reaction. Hearing status was assessed with pure-tone audiometry and auditory brainstem response. Computer tomography scans were evaluated to define the pattern of structural changes in the temporal bones. Six novel (p.Gln27*, p.Glu187*, p.Leu217*, p.Gln275*, p.Gln306*, p.Val324Asp) and two known (p.Ala116fs141*, p.Leu208*) POU3F4 mutations were detected in the studied cohort. All probands with POU3F4 defects suffered from bilateral, prelingual, severe to profound HL. Morphological changes of the temporal bone in these patients presented a similar pattern, including malformations of the internal auditory canal, vestibular aqueduct, modiolus and vestibule. Despite different localization in the POU3F4 gene all mutations severely impair the protein structure affecting at least one functional POU3F4 domain, and results in similar and severe clinical manifestations. Sequencing of the entire POU3F4 gene is recommended in patients with characteristic temporal bone malformations. Results of POU3F4 mutation testing are important not only for a proper genetic counseling, but also for adequate preparation and conduction of a surgical procedure.


  • Open Access

    Direct round window stimulation with the Med-El Vibrant Soundbridge: 5 years of experience using a technique without interposed fascia

    by Henryk Skarzynski, Lukasz Olszewski, Piotr H. Skarzynski, Artur Lorens, Anna Piotrowska, Marek Porowski, Maciej Mrowka, Adam Pilka

    The objective of this study was to present 5 years of surgical experience, and the extended results of hearing preservation (based on 3-year follow-up), with the Med-El Vibrant Soundbridge (VSB) in which the floating mass transducer (FMT) is placed directly against the round window membrane, and the fascia is used only as covering tissue to keep it in position. A retrospective survey of surgical and audiological data was conducted to evaluate the performance and stability of patient hearing, with audiometric measurements performed over fixed time intervals up to 36 months. 21 patients, aged 19–62 years (mean 48.4), with mixed or conductive, bilateral or unilateral hearing loss were included in this study. Surgical intervention involved monaural implantation of the Med-El VSB between 2006 and 2009. The results were assessed using pure tone audiometry. In 5 years of experience with the technique, no significant complications or device extrusion were observed except for two revision surgeries requiring FMT repositioning. In the 3-year follow-up, we observed stable hearing in the implanted ear. It is concluded that direct round window stimulation without interposed fascia is an alternative for patients with hearing impairment caused by chronic otitis media and/or lack of ossicles, especially after modified radical mastoidectomy. It allows good results in a selected group of patients, although further observation on a larger population is needed to confirm long-term validity and effectiveness.


  • Open Access

    A three-dimensional finite element model of round window membrane vibration before and after stapedotomy surgery

    by Monika Kwacz, Piotr Marek, Paweł Borkowski, Maciej Mrówka

    Piston stapes prostheses are implanted in patients with refractory conductive or mixed hearing loss due to stapes otosclerosis to stimulate the perilymph with varying degrees of success. The overclosure effect described by the majority of researchers affects mainly low and medium frequencies, and a large number of patients report a lack of satisfactory results for frequencies above 2 kHz. The mechanics of perilymph stimulation with the piston have not been studied in a systematic manner. The objective of this study was to assess the influence of stapedotomy surgery on round window membrane vibration and to estimate the postoperative outcomes using the finite element (FE) method. The study hypothesis is that the three-dimensional FE model developed of the human inner ear, which simulates the round window (RW) membrane vibration, can be used to assess the influence of stapedotomy on auditory outcomes achieved after the surgical procedure. An additional objective of the study was to enable the simulation of RW membrane vibration after stapedotomy using a new type of stapes prosthesis currently under investigation at Warsaw University of Technology. A three-dimensional finite element (FE) model of the human inner ear was developed and validated using experimental data. The model was then used to simulate the round window membrane vibration before and after stapedotomy surgery. Functional alterations of the RW membrane vibration were derived from the model and compared with the results of experimental measurements from temporal bones of a human cadaver. Piston stapes prosthesis implantation causes an approximately fivefold (14 dB) lower amplitude of the RW membrane vibrations compared with normal anatomical conditions. A satisfactory agreement between the FE model and the experimental data was found. The new prosthesis caused an increase of 20–30 dB in the RW displacement amplitude compared with the 0.4-mm piston prosthesis. In all frequencies, the FE model predicted a RW displacement curve that was above the experimental curves for the normal ear. The stapedotomy can be well simulated by the FE model to predict the auditory outcomes achieved following this otosurgery procedure. The 3D FE model developed in this study may be used to optimize the geometry of a new type of stapes prosthesis in order to achieve a similar sound transmission through the inner ear as for a normal middle ear. This should provide better auditory outcomes for patients with stapedial otosclerosis.


    • 1 January 2012
      • Vol. 14  (2) , 67-73

    Differences in the perilymph fluid stimulation before and after experimental stapedotomy.

    by Monika Kwacz, Maciej Mrówka, Jarosław Wysocki

    A stapedotomy surgery using a piston stapes prosthesis significantly modifies the perilymph fluid stimulation level and always leads to alteration of conditions in sound transmission through the cochlea. This paper shows the results of non-contact measurements of the stapes head velocity, a Teflon piston stapes prosthesis velocity and round window velocity conducted in freshly harvested human cadaver temporal bone specimens. The vibration patterns were measured within the frequency range of 0.4-10 kHz at the sound pressure level of 90 dB administered to the external auditory canal in the same specimen before and after experimental stapedotomy. It was shown that the vibrations of the stapes Teflon piston prosthesis and the physiological stapes are similar and approximately five-fold lower amplitude of the round window membrane vibrations compared to a physiologic situation is caused by piston shape of the stapes prosthesis. The results in this report are the part of a larger study designed to develop a new type of chamber stapes or whole middle ear prosthesis.


  • Comparison of round-window membrane mechanics before and after experimental stapedotomy

    by Jarosław Wysocki, Monika Kwacz, Maciej Mrówka, Henryk Skarżyński

    Background: Surgical intervention within the area of the middle ear always leads to alteration of conditions in its biomechanical system. This fact may provide an explanation for the lack of expected auditory outcome, although an apparently good anatomic outcome was obtained. In the case of stapedotomy, the majority of patients report lack of satisfactory results for frequencies above 2,000 Hz. The effect has not been experimentally investigated yet. Methods: This study, conducted in four human temporal bones, yielded a record of round‐window membrane vibration amplitude and phase in the frequency function (400 Hz–10 kHz) at the sound intensity level of 90 dB administered to the external auditory canal in a physiologic condition and following implantation of a Teflon piston stapes prosthesis. The procedure of experimental stapedotomy was performed with the tympanic membrane preserved from the maximally dilated approach through the posterior tympanotomy. Results: Stapes Teflon piston prosthesis implantation was found to cause approximately fivefold lower amplitude of round‐window membrane vibrations compared to a physiologic situation for frequencies above 2 kHz in particular. Conclusions: After stapedotomy, with the use of a Teflon piston prosthesis, stimulation of inner ear structures diminishes, especially in higher frequencies.


    • 1 January 2011
      • Vol. 13  (3) , 27-33

    Round window membrane motion before and after stapedotomy surgery - an experimental study.

    by Monika Kwacz, Maciej Mrowka, Jarosław Wysocki

    This paper presents the results of non-contact measurements of the human ear round window (RW) membrane motion in freshly harvested human cadaver temporal bone specimens. A PSV 400 Scanning Laser Vibrometer system (Polytec, Waldbronn, Germany) was used to determine the effect of stapedotomy on the sound-induced displacement amplitude of the RW membrane. The vibration patterns were measured in the frequency range of 0.4-10 kHz in four specimens with air conduction stimulation at 90 dB SPL applied to the external auditory canal. It was shown that the vibration amplitude of the RW membrane after stapes piston prosthesis implantation, in comparison with a physiological specimen, was reduced several times. The motion of the RW membrane can be used to determine the cochlear stimulation for the evaluation of middle ear ossicle reconstruction, especially in the case of otosclerosis surgery.