Improved left atrial appendage closure procedural efficiency using radiofrequency transseptal wire system
Open Access
- 10 January 2023
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 101 (2) , 460-467
Abstract
Objective: The radiofrequency (RF) needle has been shown to improve transseptal puncture efficiency and safety compared to mechanical needles. This study aimed to investigate the use of VersaCross RF transseptal wire system (Baylis Medical) to improve procedural efficiency of left atrial appendage closure (LAAC) compared to the standard RF needle‐based workflow.Methods: Eighty‐one LAAC procedures using WATCHMAN FLX were retrospectively analyzed comparing the standard RF needle‐based workflow to a RF wire‐based workflow. Study primary endpoint was time to WATCHMAN device release, and secondary endpoints were transseptal puncture time, LAAC success, fluoroscopy use, and procedural complications.Results: Twenty‐five cases using standard RF needle‐based workflow were compared to 56 cases using the RF wire‐based workflow. Baseline patient characteristics were similar between both groups. LAAC was successful in all patients with no differences in intraprocedural complication rates (p = 0.40). Transseptal puncture time was 1.3 min faster using the RF wire‐based workflow compared to the standard RF needle‐based workflow (6.5 ± 2.3 vs. 7.8 ± 2.3 min, p = 0.02). Overall, time to final WATCHMAN device release was 4.5 min faster with the RF wire‐based workflow compared to the RF needle‐based workflow (24.6 ± 5.6 vs. 29.1 ± 9.6 min, p = 0.01). Fluoroscopy time was 21% lower using the RF wire‐based workflow (7.6 ± 2.8 vs. 9.6 ± 4.4 min; p = 0.05) and fluoroscopy dose was 67% lower (47.1 ± 35.3 vs. 144.9 ± 156.9 mGy, p = 0.04) and more consistent (F‐test, p ˂ 0.0001).Conclusions: The RF wire‐based workflow streamlines LAAC procedures, improving LAAC efficiency and safety by reducing fluoroscopy, device exchanges, and delivery sheath manipulation.Keywords
This publication has 18 references indexed in Scilit:
- Randomized Trial of Conventional Transseptal Needle Versus Radiofrequency Energy Needle Puncture for Left Atrial Access (the TRAVERSE‐LA Study)Journal of the American Heart Association, 2013
- The use of a radiofrequency needle improves the safety and efficacy of transseptal puncture for atrial fibrillation ablationHeart Rhythm, 2011
- Prospective comparison between conventional transseptal puncture and transseptal needle puncture with radiofrequency energyJournal of Interventional Cardiac Electrophysiology, 2011
- Troubleshooting Difficult Transseptal CatheterizationJournal of Cardiovascular Electrophysiology, 2011
- Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trialThe Lancet, 2009
- Interatrial Septum Thickness and Difficulty with Transseptal Puncture during Redo Catheter Ablation of Atrial FibrillationPacing and Clinical Electrophysiology, 2008
- The change in the fluoroscopy-guided transseptal puncture site and difficult punctures in catheter ablation of recurrent atrial fibrillationEP Europace, 2008
- Meta-analysis: Antithrombotic Therapy to Prevent Stroke in Patients Who Have Nonvalvular Atrial FibrillationAnnals of Internal Medicine, 2007
- Fluoroscopy: Patient Radiation Exposure IssuesRadioGraphics, 2001
- Atrial fibrillation as an independent risk factor for stroke: the Framingham Study.Stroke, 1991