Immunostick Test for Detecting ζ-Globin Chains and Screening of the Southeast Asian α-Thalassemia 1 Deletion
Authors:
- Supansa PataSPSupansa Pata
- Matawee PongpaiboonMPMatawee Pongpaiboon
- Witida LaopajonWLWitida Laopajon
- Thongperm MunkongdeeTMThongperm Munkongdee
- Kittiphong PaiboonsukwongKPKittiphong Paiboonsukwong
- Sakorn PornpresertSPSakorn Pornpresert
- Suthat FucharoenSFSuthat Fucharoen
- Watchara KasinrerkWKWatchara Kasinrerk
Open Access
- 1 August 2019
- journal article
- research article
- Published by Springer Nature in Biological Procedures Online
- Vol. 21 (1) , 1-11
Abstract
Couples who carry α-thalassemia-1 deletion are at 25% risk of having a fetus with hemoglobin Bart’s hydrops fetalis. Southeast Asian deletion (−-(SEA)) is the most common type of α-thalassemia 1 among Southeast Asian populations. Thus, identification of the (−-(SEA)) α-thalassemia 1 carrier is necessary for controlling severe α-thalassemia in Southeast Asian countries. Using our generated anti ζ-globin chain monoclonal antibodies (mAbs) clones PL2 and PL3, a simple immunostick test for detecting ζ-globin chain presence in whole blood lysates was developed. The procedure of the developed immunostick test was as follows. The immunostick paddles were coated with 50 μg/mL of mAb PL2 as capture mAb, or other control antibodies. The coated immunostick was dipped into cocktail containing tested hemolysate at dilution of 1:500, 0.25 μg/mL biotin-labeled mAb PL3 and horseradish peroxidase-conjugated streptavidin at dilution of 1:1000. The immunostick was then dipped in precipitating substrate and the presence of ζ-globin chain in the tested sample was observed by the naked eye. Upon validation of the developed immunostick test with various types of thalassemia and normal subjects, 100% sensitivity and 82% specificity for detection of the (−-(SEA)) α-thalassemia-1 carriers were achieved. The mAb pre-coated immunostick can be stored at room temperature for at least 20 weeks. In this study, a novel simple immunostick test for the screening of (−-(SEA)) α-thalassemia 1 carriers was presented. The developed immunostick test, within a single test, contains both positive and negative internal procedural controls.Keywords
Funding Information
- Innovation Hubs of Thailand 4.0 project
- TRF and the Thailand Office of Higher Education Commission (MRG6080269, MRG6180253)
- TRF Senior Research Scholar (RTA5980007)
- Chiang Mai Center of Excellence Project, Chiang Mai University
- TRF Distinguished Research Professor Grant (DPG6080003)
This publication has 29 references indexed in Scilit:
- Development of a fluorescence immunochromatographic assay for the detection of zeta globin in the blood of (−−SEA) α-thalassemia carriersBlood Cells, Molecules, and Diseases, 2012
- Alpha-thalassemiaGenetics in Medicine, 2011
- α-thalassaemiaOrphanet Journal of Rare Diseases, 2010
- A comparison of the accuracy of the corpuscular fragility and mean corpuscular volume tests for the alpha‐thalassemia 1 and beta‐thalassemia traitsInternational Journal of Gynecology & Obstetrics, 2009
- Comparison of Sebia Capillarys Capillary Electrophoresis With the Primus High-Pressure Liquid Chromatography in the Evaluation of HemoglobinopathiesAmerican Journal of Clinical Pathology, 2008
- Alpha-thalassaemiaSeminars in Fetal and Neonatal Medicine, 2008
- A Multicenter Trial of the Effectiveness of ζ-Globin Enzyme-Linked Immunosorbent Assay and Hemoglobin H Inclusion Body Screening for the Detection of α0-Thalassemia TraitAmerican Journal of Clinical Pathology, 2008
- α‐Thalassemia: Hb H Disease and Hb Barts Hydrops FetalisAnnals of the New York Academy of Sciences, 2005
- Sensitivity and specificity of mean corpuscular volume testing for screening for α‐thalassemia‐1 and β‐thalassemia traitsJournal of Obstetrics and Gynaecology Research, 2005
- ThalassemiaHematology-American Society Hematology Education Program, 2004