Matawee Pongpaiboon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matawee Pongpaiboon has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Kittiphong Paiboonsukwong
Thalassemia Research Center, Institute of Molecular Biosciences, Mahidol University, Nakorn Pathom, 73170 Thailand
1 shared publication - Sakorn Pornprasert
Division of Clinical Microscopy, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand
1 shared publication - Supansa Pata
Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand
1 shared publication - Suthat Fucharoen
Thalassemia Research Center, Institute of Molecular Biosciences, Mahidol University, Nakhon Pathom 73170, Thailand
1 shared publication - Thongperm Munkongdee
Thalassemia Research Center, Institute of Molecular Biosciences, Mahidol University, Nakorn Pathom, 73170 Thailand
1 shared publication - Watchara Kasinrerk
Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai 50200, Thailand
1 shared publication
Latest Publications
- Open Access
- 1 August 2019
- Published by Springer Nature in Biological Procedures Online
- Vol. 21 (1) , 1-11
Immunostick Test for Detecting ζ-Globin Chains and Screening of the Southeast Asian α-Thalassemia 1 Deletion
Couples who carry α-thalassemia-1 deletion are at 25% risk of having a fetus with hemoglobin Bart’s hydrops fetalis. Southeast Asian deletion (−-(SEA)) is the most common type of α-thalassemia 1 among Southeast Asian populations. Thus, identification of the (−-(SEA)) α-thalassemia 1 carrier is necessary for controlling severe α-thalassemia in Southeast Asian countries. Using our generated anti ζ-globin chain monoclonal antibodies (mAbs) clones PL2 and PL3, a simple immunostick test for detecting ζ-globin chain presence in whole blood lysates was developed. The procedure of the developed immunostick test was as follows. The immunostick paddles were coated with 50 μg/mL of mAb PL2 as capture mAb, or other control antibodies. The coated immunostick was dipped into cocktail containing tested hemolysate at dilution of 1:500, 0.25 μg/mL biotin-labeled mAb PL3 and horseradish peroxidase-conjugated streptavidin at dilution of 1:1000. The immunostick was then dipped in precipitating substrate and the presence of ζ-globin chain in the tested sample was observed by the naked eye. Upon validation of the developed immunostick test with various types of thalassemia and normal subjects, 100% sensitivity and 82% specificity for detection of the (−-(SEA)) α-thalassemia-1 carriers were achieved. The mAb pre-coated immunostick can be stored at room temperature for at least 20 weeks. In this study, a novel simple immunostick test for the screening of (−-(SEA)) α-thalassemia 1 carriers was presented. The developed immunostick test, within a single test, contains both positive and negative internal procedural controls.
- 1 August 2019
- Published by Springer Nature in Biological Procedures Online
- Vol. 21 (1) , 1-11
Open AccessImmunostick Test for Detecting ζ-Globin Chains and Screening of the Southeast Asian α-Thalassemia 1 Deletion
Couples who carry α-thalassemia-1 deletion are at 25% risk of having a fetus with hemoglobin Bart’s hydrops fetalis. Southeast Asian deletion (−-(SEA)) is the most common type of α-thalassemia 1 among Southeast Asian populations. Thus, identification of the (−-(SEA)) α-thalassemia 1 carrier is necessary for controlling severe α-thalassemia in Southeast Asian countries. Using our generated anti ζ-globin chain monoclonal antibodies (mAbs) clones PL2 and PL3, a simple immunostick test for detecting ζ-globin chain presence in whole blood lysates was developed. The procedure of the developed immunostick test was as follows. The immunostick paddles were coated with 50 μg/mL of mAb PL2 as capture mAb, or other control antibodies. The coated immunostick was dipped into cocktail containing tested hemolysate at dilution of 1:500, 0.25 μg/mL biotin-labeled mAb PL3 and horseradish peroxidase-conjugated streptavidin at dilution of 1:1000. The immunostick was then dipped in precipitating substrate and the presence of ζ-globin chain in the tested sample was observed by the naked eye. Upon validation of the developed immunostick test with various types of thalassemia and normal subjects, 100% sensitivity and 82% specificity for detection of the (−-(SEA)) α-thalassemia-1 carriers were achieved. The mAb pre-coated immunostick can be stored at room temperature for at least 20 weeks. In this study, a novel simple immunostick test for the screening of (−-(SEA)) α-thalassemia 1 carriers was presented. The developed immunostick test, within a single test, contains both positive and negative internal procedural controls.