S-MRUT: Sectored-Multiring Ultrasonic Transducer for Selective Powering of Brain Implants
- 9 June 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (1) , 191-200
Abstract
One of the main challenges of the current ultrasonic transducers for powering brain implants is the complexity of focusing ultrasonic waves in various axial and lateral directions. The available transducers usually use electrically controlled phased array for beamforming the ultrasonic waves, which increases the complexity of the system even further. In this paper, we propose a straightforward solution for selective powering of brain implants to remove the complexity of conventional phased arrays. Our approach features a Sectored-Multi Ring Ultrasonic Transducer (S-MRUT) on a single piezoelectric sheet, specifically designed for powering implantable devices for optogenetics in freely moving animals. The proposed uni-directional S-MRUT is capable of focusing the ultrasonic waves on brain implants located at different depths and regions of the brain. The S-MRUT is designed based on Fresnel Zone Plate (FZP) theory, simulated in COMSOL, and fabricated with microfabrication process. The acoustic profile of the seven different configurations of the SMRUT were measured using a hydrophone with the total number of 7436 grid points. The measurements show the ability of the proposed S-MRUT to sweep the focus point of the acoustic waves in the axial direction in depths of 1 – 3mm, which is suitable for powering implants in the striatum of the mouse. Furthermore, the proposed S-MRUT demonstrates a steering area with the average radius of 0:862mm, and 0:678mm in experiments, and simulations, respectively. The S-MRUT is designed with the size of 3.8 × 3.8 × 0.5mm3 and the weight of 0:054gr, showing that it is compact and light enough to be worn by a mouse. Finally, the S-MRUT was tested in our measurement setup, where it successfully transfers sufficient power to a 2:8mm3 optogentic stimulator to turn on a microLED on the stimulator.Keywords
Funding Information
- European Union’s Horizon 2020 Research and Innovation Program through the project STARDUST (767092)
This publication has 33 references indexed in Scilit:
- Equivalent Circuit Models for Large Arrays of Curved and Flat Piezoelectric Micromachined Ultrasonic TransducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2016
- Optogenetics: 10 years of microbial opsins in neuroscienceNature Neuroscience, 2015
- A Power-Efficient Switched-Capacitor Stimulating System for Electrical/Optical Deep Brain StimulationIEEE Journal of Solid-State Circuits, 2014
- Localization of Ultrasound-Induced In Vivo Neurostimulation in the Mouse ModelUltrasound in Medicine & Biology, 2014
- Real-time multimodal optical control of neurons and muscles in freely behaving Caenorhabditis elegansNature Methods, 2011
- Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's diseaseThe Lancet Neurology, 2009
- Projected number of people with Parkinson disease in the most populous nations, 2005 through 2030Neurology, 2007
- A Three-dimensional MRI Atlas of the Mouse Brain with Estimates of the Average and VariabilityCerebral Cortex, 2004
- Micromachined acoustic-wave liquid ejectorJournal of Microelectromechanical Systems, 2001
- Optimum beam steering of linear phased arraysWave Motion, 1999