Tanmay Mondal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tanmay Mondal has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Brian Corbett
Tyndall National Institute, Lee Maltings, Cork, Ireland
5 shared publications - Amin Rashidi
Delft University of Technology,Dept. of Microelectronics,Delft,The Netherlands
4 shared publications - Farshad Moradi
Institute of Mechanical and Electrical Engineering, Southern Denmark University, Odense, Denmark
3 shared publications - Kjeld Laursen
Department of Electrical Engineering, Integrated Nanoelectronics Group, Aarhus University, Aarhus, Denmark
3 shared publications - Seyedsina Hosseini
Department of Health Technology Magnetic Resonance, Technical University of Denmark, Lyngby, Denmark
3 shared publications Farshad Moradi
Department of Electrical and Computer Engineering, Aarhus University, Aarhus, Denmark
2 shared publications
Latest Publications
- 23 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 70 (10) , 3937-3941
An Ultrasonically-Powered System for 1.06 mm3 Implantable Optogenetics and Drug Delivery Dust
This paper presents an ultrasonically powered micro-system for deep tissue optogenetic stimulation. The developed system is composed of a Base for Powering and Controlling (BPC) and an implantable Dust for optogenetics and drug delivery. The Dust consists of a piezoelectric crystal, a rectifier chip, and a micro-scale custom-designed light-emitting-diode (μLED) integrated, miniaturized, and envisioned to be used for freely moving animal studies. The proposed Dust operates in frequencies up to 5 MHz, power levels in the 0–10 mW range, achieves start-up within 1.8 μs at 2.9 MHz operating frequency at 14.4 mW/mm2 ultrasound power density, and 98.1% chip efficiency at 2 mW input power. With the BPC implemented and attached to (500 μm)3 PZT4 crystals, set to 60 V at 2.8 MHz operating frequency at 3 mm distance in demineralized water, the dust delivered up to 6 mW to its load (μLED for optogenetics), which translates to 0.11% total system efficiency.
- 23 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 70 (10) , 3937-3941
An Ultrasonically-Powered System for 1.06 mm3 Implantable Optogenetics and Drug Delivery Dust
This paper presents an ultrasonically powered micro-system for deep tissue optogenetic stimulation. The developed system is composed of a Base for Powering and Controlling (BPC) and an implantable Dust for optogenetics and drug delivery. The Dust consists of a piezoelectric crystal, a rectifier chip, and a micro-scale custom-designed light-emitting-diode (μLED) integrated, miniaturized, and envisioned to be used for freely moving animal studies. The proposed Dust operates in frequencies up to 5 MHz, power levels in the 0–10 mW range, achieves start-up within 1.8 μs at 2.9 MHz operating frequency at 14.4 mW/mm2 ultrasound power density, and 98.1% chip efficiency at 2 mW input power. With the BPC implemented and attached to (500 μm)3 PZT4 crystals, set to 60 V at 2.8 MHz operating frequency at 3 mm distance in demineralized water, the dust delivered up to 6 mW to its load (μLED for optogenetics), which translates to 0.11% total system efficiency.
- 25 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 6, 33-36
Ultrasonically Powered and Controlled Microsystem for Dual-Wavelength Optogenetics With a Multiload Regulation Scheme
This paper presents an ultrasonically powered dual-wavelength optogenetic device that targets simultaneous excitation and inhibition of neural activities, or in a broader sense, optical stimulation in two distinct wavelengths for targeting different populations of neurons. This can be applied to a variety of neurological disorders. The device features a load regulator circuit that shares the available power budget between two μLEDs in a power-efficient and controlled way suppressing the need for adaptive matching and overvoltage protection circuits. Furthermore, the regulator circuit is capable of detecting power burst availability on the device and generating a control signal, accordingly. For 5.25mW acoustic power at the device’s surface, the rectified voltage, and the total current load of the system are regulated to 2.79 V and 600 μA, respectively. The maximum chip and device efficiencies of 92.5 % and 31.8 % are measured, respectively. The total die area in 180 nm CMOS technology nose and the estimated system volume are 0.16 mm2 and 0.572 mm3, respectively.
- 25 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 6, 33-36
Ultrasonically Powered and Controlled Microsystem for Dual-Wavelength Optogenetics With a Multiload Regulation Scheme
This paper presents an ultrasonically powered dual-wavelength optogenetic device that targets simultaneous excitation and inhibition of neural activities, or in a broader sense, optical stimulation in two distinct wavelengths for targeting different populations of neurons. This can be applied to a variety of neurological disorders. The device features a load regulator circuit that shares the available power budget between two μLEDs in a power-efficient and controlled way suppressing the need for adaptive matching and overvoltage protection circuits. Furthermore, the regulator circuit is capable of detecting power burst availability on the device and generating a control signal, accordingly. For 5.25mW acoustic power at the device’s surface, the rectified voltage, and the total current load of the system are regulated to 2.79 V and 600 μA, respectively. The maximum chip and device efficiencies of 92.5 % and 31.8 % are measured, respectively. The total die area in 180 nm CMOS technology nose and the estimated system volume are 0.16 mm2 and 0.572 mm3, respectively.
- Open Access
- 22 March 2022
- Published by Wiley in Advanced Photonics Research
- Vol. 3 (8)
Transfer Printing of Roughened GaN‐Based Light‐Emitting Diodes into Reflective Trenches for Visible Light Communication
There is a great need to integrate dissimilar visible light components for the fabrication of thin, flexible, and 3D structures in the next generations of display and communication systems. Compared with monolithic integration, microtransfer printing (μTP) of miniaturized devices allows the heterogeneous assembly of diverse devices in a scalable and cost‐effective manner for expanded functionality. Here, advantages of μTP technology to boost the directional light output of light‐emitting diodes (LEDs) are demonstrated with a remarkable sevenfold enhancement compared with devices on the original substrate. This is achieved using an original integrated approach to roughen the backside of the GaN‐on‐Si LEDs during their release together with their printing into 10 μm‐deep reflective trenches formed in a new substrate. To address the bending of the 110 × 110 μm2 LEDs due to the internal stress from the GaN layers, compensational stress with deposited SiNx is engineered, which results in flat surfaces and successful transfer printing. Finally, the LEDs in trench are used in visible light communication (VLC), showing higher signal‐to‐noise ratio and lower bit‐error rate compared with a flat platform due to higher power collected. This strategy could be used to integrate different colors of LEDs for enhanced VLC as well as in displays.
- 22 March 2022
- Published by Wiley in Advanced Photonics Research
- Vol. 3 (8)
Open AccessTransfer Printing of Roughened GaN‐Based Light‐Emitting Diodes into Reflective Trenches for Visible Light Communication
There is a great need to integrate dissimilar visible light components for the fabrication of thin, flexible, and 3D structures in the next generations of display and communication systems. Compared with monolithic integration, microtransfer printing (μTP) of miniaturized devices allows the heterogeneous assembly of diverse devices in a scalable and cost‐effective manner for expanded functionality. Here, advantages of μTP technology to boost the directional light output of light‐emitting diodes (LEDs) are demonstrated with a remarkable sevenfold enhancement compared with devices on the original substrate. This is achieved using an original integrated approach to roughen the backside of the GaN‐on‐Si LEDs during their release together with their printing into 10 μm‐deep reflective trenches formed in a new substrate. To address the bending of the 110 × 110 μm2 LEDs due to the internal stress from the GaN layers, compensational stress with deposited SiNx is engineered, which results in flat surfaces and successful transfer printing. Finally, the LEDs in trench are used in visible light communication (VLC), showing higher signal‐to‐noise ratio and lower bit‐error rate compared with a flat platform due to higher power collected. This strategy could be used to integrate different colors of LEDs for enhanced VLC as well as in displays.
- 9 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (1) , 191-200
S-MRUT: Sectored-Multiring Ultrasonic Transducer for Selective Powering of Brain Implants
One of the main challenges of the current ultrasonic transducers for powering brain implants is the complexity of focusing ultrasonic waves in various axial and lateral directions. The available transducers usually use electrically controlled phased array for beamforming the ultrasonic waves, which increases the complexity of the system even further. In this paper, we propose a straightforward solution for selective powering of brain implants to remove the complexity of conventional phased arrays. Our approach features a Sectored-Multi Ring Ultrasonic Transducer (S-MRUT) on a single piezoelectric sheet, specifically designed for powering implantable devices for optogenetics in freely moving animals. The proposed uni-directional S-MRUT is capable of focusing the ultrasonic waves on brain implants located at different depths and regions of the brain. The S-MRUT is designed based on Fresnel Zone Plate (FZP) theory, simulated in COMSOL, and fabricated with microfabrication process. The acoustic profile of the seven different configurations of the SMRUT were measured using a hydrophone with the total number of 7436 grid points. The measurements show the ability of the proposed S-MRUT to sweep the focus point of the acoustic waves in the axial direction in depths of 1 – 3mm, which is suitable for powering implants in the striatum of the mouse. Furthermore, the proposed S-MRUT demonstrates a steering area with the average radius of 0:862mm, and 0:678mm in experiments, and simulations, respectively. The S-MRUT is designed with the size of 3.8 × 3.8 × 0.5mm3 and the weight of 0:054gr, showing that it is compact and light enough to be worn by a mouse. Finally, the S-MRUT was tested in our measurement setup, where it successfully transfers sufficient power to a 2:8mm3 optogentic stimulator to turn on a microLED on the stimulator.
- 9 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (1) , 191-200
S-MRUT: Sectored-Multiring Ultrasonic Transducer for Selective Powering of Brain Implants
One of the main challenges of the current ultrasonic transducers for powering brain implants is the complexity of focusing ultrasonic waves in various axial and lateral directions. The available transducers usually use electrically controlled phased array for beamforming the ultrasonic waves, which increases the complexity of the system even further. In this paper, we propose a straightforward solution for selective powering of brain implants to remove the complexity of conventional phased arrays. Our approach features a Sectored-Multi Ring Ultrasonic Transducer (S-MRUT) on a single piezoelectric sheet, specifically designed for powering implantable devices for optogenetics in freely moving animals. The proposed uni-directional S-MRUT is capable of focusing the ultrasonic waves on brain implants located at different depths and regions of the brain. The S-MRUT is designed based on Fresnel Zone Plate (FZP) theory, simulated in COMSOL, and fabricated with microfabrication process. The acoustic profile of the seven different configurations of the SMRUT were measured using a hydrophone with the total number of 7436 grid points. The measurements show the ability of the proposed S-MRUT to sweep the focus point of the acoustic waves in the axial direction in depths of 1 – 3mm, which is suitable for powering implants in the striatum of the mouse. Furthermore, the proposed S-MRUT demonstrates a steering area with the average radius of 0:862mm, and 0:678mm in experiments, and simulations, respectively. The S-MRUT is designed with the size of 3.8 × 3.8 × 0.5mm3 and the weight of 0:054gr, showing that it is compact and light enough to be worn by a mouse. Finally, the S-MRUT was tested in our measurement setup, where it successfully transfers sufficient power to a 2:8mm3 optogentic stimulator to turn on a microLED on the stimulator.
- 3 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (3) , 583-594
Ultrasonically Powered Compact Implantable Dust for Optogenetics
This paper presents an ultrasonically powered microsystem for deep tissue optogenetic stimulation. All the phases in developing the prototype starting from modelling the piezoelectric crystal used for energy harvesting, design, simulation and measurement of the chip, and finally testing the whole system in a mimicking setup are explained. The developed system is composed of a piezoelectric harvesting cube, a rectifier chip, and a micro-scale custom-designed light-emitting-diode (LED), and envisioned to be used for freely moving animal study. The proposed rectifier chip with a silicon area of 300μm×300μm is implemented in standard TSMC 0.18μm CMOS technology, for interfacing the piezoelectric cube and the microLED. Experimental results show that the proposed microsystem produces an available electrical power of 2.2 mW while loaded by amicroLED, out of an acoustic intensity of $7.2mW/mm^{2}$ using a $1mm^{3}$ crystal as the receiver. The whole system including the tested rectifier chip, a piezoelectric cube with the dimensions of $(500μm)^{3}$ , and a LED of 300μm×130μm have been integrated on a 3mm×1.5mm glass substrate, encapsulated inside a bio-compatible PDMS layer and tested successfully for final prototyping. The total volume of the fully-packaged device is estimated around $2.85mm^{3}$ .- 3 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (3) , 583-594
Ultrasonically Powered Compact Implantable Dust for Optogenetics
This paper presents an ultrasonically powered microsystem for deep tissue optogenetic stimulation. All the phases in developing the prototype starting from modelling the piezoelectric crystal used for energy harvesting, design, simulation and measurement of the chip, and finally testing the whole system in a mimicking setup are explained. The developed system is composed of a piezoelectric harvesting cube, a rectifier chip, and a micro-scale custom-designed light-emitting-diode (LED), and envisioned to be used for freely moving animal study. The proposed rectifier chip with a silicon area of 300μm×300μm is implemented in standard TSMC 0.18μm CMOS technology, for interfacing the piezoelectric cube and the microLED. Experimental results show that the proposed microsystem produces an available electrical power of 2.2 mW while loaded by amicroLED, out of an acoustic intensity of $7.2mW/mm^{2}$ using a $1mm^{3}$ crystal as the receiver. The whole system including the tested rectifier chip, a piezoelectric cube with the dimensions of $(500μm)^{3}$ , and a LED of 300μm×130μm have been integrated on a 3mm×1.5mm glass substrate, encapsulated inside a bio-compatible PDMS layer and tested successfully for final prototyping. The total volume of the fully-packaged device is estimated around $2.85mm^{3}$ .- Open Access
- 2 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11364, 113641I
Realization of high efficiency ultrasound-powered micro-LEDs for optogenetics
We present the fabrication, characterization, and demonstration of high-efficiency ultrasound-powered micro- light emitting diodes (μLED) for use in optogenetic applications. InGaN based blue-emitting LED material wafers grown on a patterned sapphire substrate (PSS) were used to assist in the out-scattering of the light. The turn-on voltage of the LEDs is around 2.5 volts and the electrical ideality factor is 1.2 confirming high radiative recombination efficiency. A power density of more than 50 mW/mm2 was obtained from a 130 x 300 μm2 LED with a mesa of 100 μm diameter at 3 mA which is much more than is required to excite channelrhodopsin transfected neural cells. A high external quantum efficiency (EQE) of 33% is obtained at 3 mA measured in an integrating sphere. The peak wavelength of the μLED was measured at 483 nm at different current densities. The μLEDs are integrated directly onto a rectifier and Piezoelectric Transducer (PZT) harvester to realise a highly efficient ultrasound-powered light delivery unit capable to generate mWs of optical power. The concept was validated by powering the integrated device with ultrasound.
- 2 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11364, 113641I
Open AccessRealization of high efficiency ultrasound-powered micro-LEDs for optogenetics
We present the fabrication, characterization, and demonstration of high-efficiency ultrasound-powered micro- light emitting diodes (μLED) for use in optogenetic applications. InGaN based blue-emitting LED material wafers grown on a patterned sapphire substrate (PSS) were used to assist in the out-scattering of the light. The turn-on voltage of the LEDs is around 2.5 volts and the electrical ideality factor is 1.2 confirming high radiative recombination efficiency. A power density of more than 50 mW/mm2 was obtained from a 130 x 300 μm2 LED with a mesa of 100 μm diameter at 3 mA which is much more than is required to excite channelrhodopsin transfected neural cells. A high external quantum efficiency (EQE) of 33% is obtained at 3 mA measured in an integrating sphere. The peak wavelength of the μLED was measured at 483 nm at different current densities. The μLEDs are integrated directly onto a rectifier and Piezoelectric Transducer (PZT) harvester to realise a highly efficient ultrasound-powered light delivery unit capable to generate mWs of optical power. The concept was validated by powering the integrated device with ultrasound.
- 13 January 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (2) , 1817-1826
Interferometric imaging of reflective micro-objects in the presence of strong aberrations
Some imaging techniques reduce the effect of optical aberrations either by detecting and actively compensating for them or by utilizing interferometry. A microscope based on a Mach-Zehnder interferometer has been recently introduced to allow obtaining sharp images of light-transmitting objects in the presence of strong aberrations. However, the method is not capable of imaging microstructures on opaque substrates. In this work, we use a Michelson interferometer to demonstrate imaging of reflecting and back-scattering objects on any substrate with micrometer-scale resolution. The system is remarkably insensitive to both deterministic and random aberrations that can completely destroy the object’s intensity image.
- 13 January 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (2) , 1817-1826
Interferometric imaging of reflective micro-objects in the presence of strong aberrations
Some imaging techniques reduce the effect of optical aberrations either by detecting and actively compensating for them or by utilizing interferometry. A microscope based on a Mach-Zehnder interferometer has been recently introduced to allow obtaining sharp images of light-transmitting objects in the presence of strong aberrations. However, the method is not capable of imaging microstructures on opaque substrates. In this work, we use a Michelson interferometer to demonstrate imaging of reflecting and back-scattering objects on any substrate with micrometer-scale resolution. The system is remarkably insensitive to both deterministic and random aberrations that can completely destroy the object’s intensity image.