Does using constrained acetabular component really limit hip range of motion?
Open Access
- 30 June 2021
- journal article
- research article
- Published by Turkish Journal of Clinics and Laboratory in TURKISH JOURNAL of CLINICS and LABORATORY
- Vol. 12 (2) , 161-165
Abstract
Aim: In surgical treatment of instability, constrained acetabular inserts are frequently used in hip arthroplasty. However the reasons why surgeons avoid constrained acetabular components are the concern of an increased rate of loosening possibly due to impingement and the concern of decreased range of motion. This study aims to investigate the influence of constrained acetabular insert usage on hip range of motions and functional results. Material and Methods: Twenty-eight patients who needed revision hip arthroplasty were included. Patients were divided into two groups according to acetabular insert used in surgery (constrained and non-constrained). Mean follow-up period was 61±7 months (range, 50-74) in constrained group and 59±7 (range, 50-72) in non-constrained group. Hip range of motion and harris hip scores were recorded pre-operatively and at final follow-up. Results: The final avarage flexion, abduction, adduction, external rotation and internal rotation was respectively 78°±15°, 43°±4°, 28°±3°, 30°±7°,19°±8° in constrained group (n=15) and 75°±14°, 40°±6°, 26°±5°, 30°±12°, 17°±6° in non-constrained group (n=13). The difference between groups was not statistically significant. Harris hip score increased in both groups and there was no significant difference between groups (p=0.730). Conclusion: Findings of this mid term study showed that hip range of motions and functional results in patients with constrained acetabular inserts are not inferior than the patients with non-constrained inserts.Keywords
This publication has 24 references indexed in Scilit:
- An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographsThe Bone & Joint Journal, 2014
- Revision Total Hip Arthroplasty in Younger Patients: Indications, Reasons for Failure, and SurvivorshipThe Physician and Sportsmedicine, 2012
- The Medium Term Outcome of the Omnifit Constrained Acetabular CupHIP International, 2012
- Constrained Cups Appear Incapable of Meeting the Demands of Revision THAClinical Orthopaedics and Related Research, 2012
- Instability after total hip arthroplastyWorld Journal of Orthopedics, 2012
- Constrained Liner in Neurologic or Cognitively Impaired Patients Undergoing Primary THAClinical Orthopaedics and Related Research, 2010
- Why Revision Total Hip Arthroplasty FailsClinical Orthopaedics and Related Research, 2009
- Ceramic–ceramic coupling with big heads: clinical outcomeEuropean Journal of Orthopaedic Surgery & Traumatology, 2007
- Constrained components for the unstable hip following total hip arthroplasty: a literature reviewInternational Orthopaedics, 2006
- The Long-term Outcome of 755 Consecutive Constrained Acetabular Components in Total Hip ArthroplastyThe Journal of Arthroplasty, 2005