Artificial Pancreas: Clinical Study in Latin America Without Premeal Insulin Boluses
- 12 July 2018
- journal article
- research article
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 12 (5) , 914-925
Abstract
Background: Emerging therapies such as closed-loop (CL) glucose control, also known as artificial pancreas (AP) systems, have shown significant improvement in type 1 diabetes mellitus (T1DM) management. However, demanding patient intervention is still required, particularly at meal times. To reduce treatment burden, the automatic regulation of glucose (ARG) algorithm mitigates postprandial glucose excursions without feedforward insulin boluses. This work assesses feasibility of this new strategy in a clinical trial. Methods: A 36-hour pilot study was performed on five T1DM subjects to validate the ARG algorithm. Subjects wore a subcutaneous continuous glucose monitor (CGM) and an insulin pump. Insulin delivery was solely commanded by the ARG algorithm, without premeal insulin boluses. This was the first clinical trial in Latin America to validate an AP controller. Results: For the total 36-hour period, results were as follows: average time of CGM readings in range 70-250 mg/dl: 88.6%, in range 70-180 mg/dl: 74.7%, <70 mg/dl: 5.8%, and <50 mg/dl: 0.8%. Results improved analyzing the final 15-hour period of this trial. In that case, the time spent in range was 70-250 mg/dl: 94.7%, in range 70-180 mg/dl: 82.6%, <70 mg/dl: 4.1%, and <50 mg/dl: 0.2%. During the last night the time spent in range was 70-250 mg/dl: 95%, in range 70-180 mg/dl: 87.7%, <70 mg/dl: 5.0%, and <50 mg/dl: 0.0%. No severe hypoglycemia occurred. No serious adverse events were reported. Conclusions: The ARG algorithm was successfully validated in a pilot clinical trial, encouraging further tests with a larger number of patients and in outpatient settings.Keywords
Funding Information
- Fundación Cellex (N/A)
- Juvenile Diabetes Research Foundation International (grant 2-SRA-2016-291-Q-R)
This publication has 70 references indexed in Scilit:
- Extended multiple model prediction with application to blood glucose regulationJournal of Process Control, 2012
- Artificial Pancreas: Past, Present, FutureDiabetes, 2011
- The Effect of Insulin Feedback on Closed Loop Glucose ControlThe Journal of Clinical Endocrinology & Metabolism, 2011
- Novel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 DiabetesDiabetes Care, 2010
- Statistical Tools to Analyze Continuous Glucose Monitor DataDiabetes Technology & Therapeutics, 2009
- Fully Automated Closed-Loop Insulin Delivery Versus Semiautomated Hybrid Control in Pediatric Patients With Type 1 Diabetes Using an Artificial PancreasDiabetes Care, 2008
- Detection of a Meal Using Continuous Glucose MonitoringDiabetes Care, 2008
- Feasibility of Automating Insulin Delivery for the Treatment of Type 1 DiabetesDiabetes, 2006
- Insulin Kinetics in Type-1 Diabetes: Continuous and Bolus Delivery of Rapid Acting InsulinIEEE Transactions on Biomedical Engineering, 2004
- Blood glucose control for type I diabetes mellitus: A robust tracking H∞ problemControl Engineering Practice, 2004