Measurement of the electrical conductivity of aqueous metal chloride solutions using a phononic crystal sensor
- 5 August 2026
- journal article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (31) , 315304
Abstract
This work proposes a novel approach for the measurement of electrical conductivity in aqueous solutions of transition metal chlorides, specifically CuCl 2 –water, FeCl 3 –water, and NiCl 2 –water using a phononic–fluidic sensor. Indeed, it establishes a direct correlation between conductivity and the frequency of a cavity mode in the phononic crystal as a function of concentration. The phononic structure consists of air holes periodically distributed in a stainless-steel matrix. Meanwhile, the designed phononic crystal structure possesses a wide phononic band gap of width of 145 kHz that could be of a distinct effect through the detection process. By introducing a transition metal chlorides as defect in the central hole of the phononic crystal, the emergence of a resonant mode is expected which in turn represents the mainstay towards the detection of metal chlorides. In this regard, our findings investigated a significant shift in the spectral position of the resonant frequency with the concentration’s changes of metal chlorides, providing a superb sensitivity with respect to the concentration of 1.88 × 10 −4 (kHz ppm −1 ) for FeCl 3 solution, 1.80 × 10 −4 (kHz ppm −1 ) for NiCl 2 and 0.83 × 10 −4 (kHz ppm −1 ) for CuCl 2 . In addition, the highest figure of merit and quality factor values are obtained for FeCl 3 , which are 767.28 × 10 −7 ppm −1 and 162.75, respectively. Moreover, the lowest detection limits of the proposed sensor are 0.024 ppm for FeCl 3 , 0.039 ppm for NiCl 2 , and 0.061 ppm for CuCl 2 . In parallel, we performed direct electrical conductivity measurements for the same concentrations. A clear and consistent correlation between the resonant frequency and the electrical conductivity was observed. Based on this correlation, a calibration curve was established, enabling the indirect estimation of electrical conductivity from resonant frequency data. The sensor sensitivity with respect to electrical conductivity was found to be 0.1889 kHz (mS −1 cm −1 ) for FeCl 3 , 0.2056 kHz (mS −1 cm −1 ) for NiCl 2 , and 0.1548 kHz (mS −1 cm −1 ) for CuCl 2 .Keywords
This publication has 38 references indexed in Scilit:
- Heavy metals biosensor based on defective one-dimensional phononic crystalsUltrasonics, 2023
- Experimental and numerical evidence of using a Phononic membrane with the coupling of Fano resonant modes as a highly sensitive temperature sensorMechanical Systems and Signal Processing, 2022
- Origin of the Acoustic Bandgaps in Hypersonic Colloidal Phononics: The Role of the Elastic ImpedanceThe Journal of Physical Chemistry B, 2022
- High-performance liquid sensor based one-dimensional phononic crystal with demultiplexing capabilityMaterials Today Communications, 2021
- Acetone sensor based 1D defective phononic crystal as a highly sensitive biosensor applicationOptical and Quantum Electronics, 2021
- Study of liquid resonances in solid-liquid composite periodic structures (phononic crystals) – theoretical investigations and practical application for in-line analysis of conventional petroleum productsSensors and Actuators B: Chemical, 2018
- Phoxonic crystals—a new platform for chemical and biochemical sensorsAnalytical and Bioanalytical Chemistry, 2013
- Sensing the characteristic acoustic impedance of a fluid utilizing acoustic pressure wavesSensors and Actuators A: Physical, 2012
- Two-dimensional phononic crystal sensor based on a cavity modeSensors and Actuators B: Chemical, 2012
- Measurement of acoustic properties of liquid using liquid flow SH-SAW sensor systemSensors and Actuators B: Chemical, 2001