Is in vivo sensing in a total hip replacement a possibility? A review on past systems and future challenges
Open Access
- 16 September 2021
- journal article
- review article
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 3 (4) , 042004
Abstract
Surgery to implant a total hip replacement (THR) is very successful in reducing pain and restoring function. This procedure has become more prevalent, and projections estimate further increases in demand. However, complications can arise, and current diagnostic techniques often fail to expose underlying issues before they result in a catastrophic failure that requires revision surgery. An instrumented implant, with embedded sensors capable of real time condition monitoring, would be an attractive proposition to incorporate within a THR. Continued advances in the performance and miniaturisation of electronic components, embedded systems, sensing and wireless communications have given the tools and resources medical device manufacturers need to innovate in the field of implantable medical devices. Smart implants are already being widely used in healthcare including pacemakers, cochlear implants, glucose monitors and insulin pumps however, a widely used smart THR has not yet been realised. Since the implantation of the first instrumented hip implant in the 1960s there have been several in vitro studies monitoring levels of implant loosening. Additionally, significant research has been conducted using instrumented THRs to perform in vivo measurement of biomechanical metrics, including force and moments. To date less than 100 patients have successfully received an instrumented implant. The results of these studies have aided researchers, designers and surgeons in wider research projects, however, the motivation behind the work was to provide discrete biomechanical data sets and not provide real-time condition monitoring of an implants performance or highlight early indications for revision surgery. If in vivo sensing within a THR is to be achieved and adopted in regular clinical practice then the following challenges need to be addressed: choice of the sensing method, biocompatibility and integration within the implant, power supply, communication, and regulatory considerations.Keywords
Funding Information
- Engineering and Physical Science Research Council (EP/R003971/1)
- Engineering and Physical Science Research Council Studentship: Centre for Doctoral Training in Tissue Engineering and Regenerative Medicine - Innovation in Medical and Biological Engineering (EP/L014823/1)
This publication has 74 references indexed in Scilit:
- Friction in Total Hip Joint Prosthesis Measured In Vivo during WalkingPLOS ONE, 2013
- Innovation and Translation Efforts in Wireless Medical Connectivity, Telemedicine and eMedicine: A Story from the RFID Center of Excellence at the University of PittsburghAnnals of Biomedical Engineering, 2013
- Development of Implantable Medical Devices: From an Engineering PerspectiveInternational Neurourology Journal, 2013
- High-Tech Hip Implant for Wireless Temperature Measurements In VivoPLOS ONE, 2012
- A vibrational technique for diagnosing loosened total hip endoprostheses: An experimental sawbone studyMedical Engineering & Physics, 2012
- Total Hip Arthroplasty – over 100 years of operative historyOrthopedic Reviews, 2011
- Future Young Patient Demand for Primary and Revision Joint Replacement: National Projections from 2010 to 2030Clinical Orthopaedics and Related Research, 2009
- Bone vibration measurement using ultrasound: Application to detection of hip prosthesis looseningMedical Engineering & Physics, 2007
- Four-channel telemetry system for in vivo measurement of hip joint forcesJournal of Biomedical Engineering, 1991
- In vivo records of hip loads using a femoral implant with telemetric output (a prelimary report)Journal of Biomedical Engineering, 1979