Latest Publications

  • Open Access

    Impingement During Dislocation-Prone Activities in Acetabular Cups with Lipped and Standard Liners: A Geometric Model

    by Mackenzie Smeeton, Simon P. Williams, James Anderson, Ruth Wilcox, Tim Board, Sophie Williams, Graham Isaac

    Background/Objectives: Asymmetric acetabular liners used in Total Hip Arthroplasty (THA) are clinically successful in reducing revision associated with dislocation. The performance of an asymmetric liner is dependent on its positioning, although few studies have directly investigated the effects of variables such as cup orientation or extended rim position on outcomes such as impingement. Therefore, the aim of this study was to compare the incidence of impingement in THA with a standard and lipped liner. Methods: A THA was virtually implanted into a previously developed geometric model. Acetabular cups were placed in a range of clinically relevant orientations, and the model was moved through seven joint motions associated with dislocation-prone Activities of Daily Living (ADLs). The occurrence of implant–implant, implant–bone, and bone–bone impingement was assessed for the standard and lipped constructs across a total of 6,237 unique combinations of cup orientation and lipped liner apex rotations. Results/Conclusions: The model predicted that with both standard and lipped constructs, there were no component placement positions which avoided impingement for all ADLs. The number of impingement incidents was minimised when components were positioned at the higher end of the manufacturer’s recommendations for cup inclination and anteversion. The use of a lipped liner increased the frequency of impingement events compared with the standard construct. However, for anterior impingement leading to posterior dislocation, this increase may be minimised by rotating the lip apex to a posterior-inferior position. Anterior lip apex placement tended to minimise the increase in the less critical posterior impingement.


  • Open Access

    Radiolucent lines in a cementless hip stem: The use of semi-automated measurements to monitor progression over a 10 year period

    by Graham H. Isaac, Rosyln S. Cassidy, Janet C. Hill, Gregory M. Pryce, Sophie Williams, Ruth K. Wilcox, David E. Beverland

    Radiolucent lines (RLLs) observed adjacent to a cementless stem following Total Hip Arthroplasty (THA) have been linked to stem loosening. Their manual assessment is susceptible to observer error. In this study a semi-automated (Auto) method was developed to characterise RLLs from Anterior-Posterior (AP) and Lateral (Lat) radiographs, evaluate their time progression and effects on clinical outcomes. The study comprised of 237 subjects with postoperative, 1 and 10 Y radiographs. Of these 131 also had 4–7 Y radiographs. All subjects also had accompanying implant, demographic and clinical outcomes data. An algorithm was written to evaluate the incidence of RLLs and post-processing was performed to characterise RLLs as ‘not present’ or ‘benign’, or significant (‘SigRLL’). The criteria for SigRLL were tuned to minimise the number of false negatives compared to a manual characterisation. The incidence of SigRLL using AP/Lat or AP only was compared and the latter was used to monitor their development over time. The relationship with clinical outcomes was evaluated. Incidence of SigRLLs using the Auto and Manual AP/Lat methods agreed in 199/237 (84.0%) of subjects. The discrepancies included seven false negatives. The Auto AP/Lat and AP methods agreed in 221/237 (93.2%) of subjects. Twenty-eight subjects with a 4–7 Y review had SigRLLs at 10 Y. Of these, 23 had SigRLLs at 4–7 Y. Greater pain was reported in the SigRLLs group ( p = 0.003). Four out of five stems subsequently revised for loosening exhibited 10 Y SigRLLs.

  • Open Access

    Measuring Relative Component Motion and Stability in Total Hip Replacements Using a Magnetic Position and Orientation Sensing System

    by Oliver G. Vickers, Peter R. Culmer, Graham H. Isaac, Robert W. Kay, Matthew P. Shuttleworth, Tim N. Board, Sophie Williams

    An instrumented total hip replacement (THR) implant capable of remote and continuous monitoring would be an attractive prospect for a surgeon to conveniently track the recovery of their patients. Measuring the relative motion of the prosthesis components would provide insight into joint kinematics and contribute to the detection of adverse events including impingement and subluxation. The aim of this study was to develop a sensing system to measure the relative orientation and translation of the prosthesis components. A tri-axis magnetometer and a permanent magnet were integrated into clinically available THR components, forming a magnetic position and orientation sensing system. A robotic arm was used to articulate the components through controlled motion routines and record the orientation of the components. The output of the robot arm and a camera tracking system were used to validate the performance of the sensing system. The sensing system measured the relative orientation of the components to two degrees of freedom with an RMSE of <4.0° and measured the displacement of the femoral head during an impingement-driven subluxation motion with an RMSE of 0.2 mm. This proof-of-concept work has shown that magnetic sensing technology can track the position and orientation of THR components. With further development, this sensing method could feature within an instrumented THR implant.


  • Open Access

    Impingement During Dislocation-Prone Activities: Geometric Modeling Analysis of an Uncemented Standard Versus Modular Dual Mobility Acetabular Cups

    by Mackenzie Smeeton, Simon P. Williams, James Anderson, Ruth Wilcox, Tim Board, Sophie Williams, Graham Isaac

    Background/Objectives: The stability of dual mobility (DM) total hip arthroplasty (THA) is often attributed to reduced impingement incidence and a superior range of motion (ROM) compared to the corresponding values when standard implants are used. However, few studies have directly explored this. Thus, the purpose of the present study was to compare the incidence of impingement and the range of motion between standard and DM acetabular cups, whose diameters are suited to the same patient anatomy. Methods: One standard and two DM implants were virtually implanted into a pelvis using a previously developed geometric model. Joint motions, which were representative of seven dislocation-prone activities of daily living (ADLs), as well as walking, were applied to each device type at a range of cup orientations (inclination/anteversion). Conclusions: There were no placement positions that avoided impingement across all seven ADLs, regardless of cup construct type. A similar impingement incidence and ROM were observed for standard and DM constructs, although the consequences of impingement are potentially more serious for DM devices (metal–metal contact) than for standard constructs (metal–polyethylene contact). This finding contradicts the common notion that DM-THAs have a reduced impingement incidence and superior ROM, instead suggesting that their stability may be attributed to alternative mechanisms, such as increased jump distance.


  • Open Access

    Analysis of Early-Retrieved Dual-Mobility Polyethylene Liners for Total Hip Replacement

    by Mackenzie Smeeton, Graham Isaac, Ruth Wilcox, James Anderson, Tim Board, Douglas W. Van Citters, Sophie Williams

    Despite their emerging use, the in vivo behaviour of dual-mobility (DM) total hip replacements (THRs) is not well understood. Therefore, the purpose of this study was to assess the articulating surfaces of 20 early-retrieved DM polyethylene liners (mean length of implantation 20.0 ± 18.8 months) for damage to improve the current understanding of their in vivo functional mechanisms. The internal and external surfaces of each liner were visually and geometrically assessed, and the material composition of embedded debris particles were further characterized. Scratching and pitting were the most common modes of damage identified on either surface, and a high incidence of burnishing (50%) and embedded debris (65%) were observed on the internal and external surfaces, respectively. Embedded debris particles were commonly titanium- or iron-based, although other materials such as cobalt-chrome and tantalum were also identified. The geometric assessment demonstrated highly variable damage patterns across the liners, with the internal surfaces commonly presenting with crescent-shaped, circumferential, or circular regions of penetration whilst the external surfaces commonly presented with regions of deep pitting or gouging. This study demonstrates that DM-THRs primarily articulate at the head/liner junction, and that polyethylene liners are capable of rotating about the femoral neck axis, although the extent of this may be limited in some cases. Additionally, this study suggests that intra-prosthetic dislocation and edge loading may remain pertinent failure mechanisms of DM implants despite the advent of highly crosslinked polyethylene and design features, thus highlighting the need for enhanced monitoring of these devices.


  • Open Access

    Inertial Tracking System for Monitoring Dual Mobility Hip Implants In Vitro

    by Matthew Peter Shuttleworth, Oliver Vickers, Mackenzie Smeeton, Tim Board, Graham Isaac, Peter Culmer, Sophie Williams, Robert William Kay

    Dual mobility (DM) implants are being increasingly used for total hip arthroplasties due to the additional range of motion and joint stability they afford over more traditional implant types. Currently, there are no reported methods for monitoring their motions under realistic operating conditions while in vitro and, therefore, it is challenging to predict how they will function under clinically relevant conditions and what failure modes may exist. This study reports the development, calibration, and validation of a novel inertial tracking system that directly mounts to the mobile liner of DM implants. The tracker was custom built and based on a miniaturized, off-the-shelf inertial measurement unit (IMU) and employed a gradient-decent sensor fusion algorithm for amalgamating nine degree-of-freedom IMU readings into three-axis orientation estimates. Additionally, a novel approach to magnetic interference mitigation using a fixed solenoid and magnetic field simulation was evaluated. The system produced orientation measurements to within 1.0° of the true value under ideal conditions and 3.9° with a negligible drift while in vitro, submerged in lubricant, and without a line of sight.


  • Open Access

    Impingement in total hip arthroplasty: A geometric model

    by Gregory M Pryce, Bismaya Sabu, Mazen Al-Hajjar, Ruth K Wilcox, Jonathan Thompson, Graham H Isaac, Tim Board, Sophie Williams

    Total Hip Arthroplasty (THA) is one of the most common and successful surgical interventions. The survivorship at 10 years for the most commonly used systems is over 95%. However, the incidence of revision is usually much higher in the 0–1 year time period following the intervention. The most common reason for revision in this early time period is dislocation and subluxation, which may be defined as complete or permanent, and partial or temporary loss of contact between the bearing surfaces respectively. This study comprises the development of a geometric model of bone and an in situ total hip replacement, to predict the occurrence and location of bone and component impingement for a wide range of acetabular cup positions and for a series of frequently practiced activities of daily living. The model developed predicts that anterior-superior component impingement is associated with activities that result in posterior dislocation. The incidence may be reduced by increased cup anteversion and inclination. Posterior-inferior component impingement is associated with anterior dislocation activities. Its incidence may be reduced by decreased cup anteversion and inclination. A component impingement-free range was identified, running from when the cup was positioned with 45° inclination and 25° anteversion to 70° inclination and 15°–20° anteversion.


  • Open Access

    Is in vivo sensing in a total hip replacement a possibility? A review on past systems and future challenges

    by O G Vickers, P R Culmer, G H Isaac, R W Kay, M P Shuttleworth, T Board, S Williams

    Surgery to implant a total hip replacement (THR) is very successful in reducing pain and restoring function. This procedure has become more prevalent, and projections estimate further increases in demand. However, complications can arise, and current diagnostic techniques often fail to expose underlying issues before they result in a catastrophic failure that requires revision surgery. An instrumented implant, with embedded sensors capable of real time condition monitoring, would be an attractive proposition to incorporate within a THR. Continued advances in the performance and miniaturisation of electronic components, embedded systems, sensing and wireless communications have given the tools and resources medical device manufacturers need to innovate in the field of implantable medical devices. Smart implants are already being widely used in healthcare including pacemakers, cochlear implants, glucose monitors and insulin pumps however, a widely used smart THR has not yet been realised. Since the implantation of the first instrumented hip implant in the 1960s there have been several in vitro studies monitoring levels of implant loosening. Additionally, significant research has been conducted using instrumented THRs to perform in vivo measurement of biomechanical metrics, including force and moments. To date less than 100 patients have successfully received an instrumented implant. The results of these studies have aided researchers, designers and surgeons in wider research projects, however, the motivation behind the work was to provide discrete biomechanical data sets and not provide real-time condition monitoring of an implants performance or highlight early indications for revision surgery. If in vivo sensing within a THR is to be achieved and adopted in regular clinical practice then the following challenges need to be addressed: choice of the sensing method, biocompatibility and integration within the implant, power supply, communication, and regulatory considerations.