Multi-scale simulations of the dynamics of in-stent restenosis: impact of stent deployment and design
Authors:
Open Access
- 30 March 2011
- journal article
- Published by The Royal Society in Interface Focus
- Vol. 1 (3) , 365-373
Abstract
Neointimal hyperplasia, a process of smooth muscle cell re-growth, is the result of a natural wound healing response of the injured artery after stent deployment. Excessive neointimal hyperplasia following coronary artery stenting results in in-stent restenosis (ISR). Regardless of recent developments in the field of coronary stent design, ISR remains a significant complication of this interventional therapy. The influence of stent design parameters such as strut thickness, shape and the depth of strut deployment within the vessel wall on the severity of restenosis has already been highlighted but the detail of this influence is unclear. These factors impact on local haemodynamics and vessel structure and affect the rate of neointima formation. This paper presents the first results of a multi-scale model of ISR. The development of the simulated restenosis as a function of stent deployment depth is compared with an in vivo porcine dataset. Moreover, the influence of strut size and shape is investigated, and the effect of a drug released at the site of injury, by means of a drug-eluting stent, is also examined. A strong correlation between strut thickness and the rate of smooth muscle cell proliferation has been observed. Simulation results also suggest that the growth of the restenotic lesion is strongly dependent on the stent strut cross-sectional profile.Keywords
This publication has 41 references indexed in Scilit:
- Understanding the Role of Endothelial Progenitor Cells in Percutaneous Coronary InterventionJACC, 2010
- Hemodynamically Driven Stent Strut DesignAnnals of Biomedical Engineering, 2009
- Materials, fluid dynamics, and solid mechanics aspects of coronary artery stents: A state‐of‐the‐art reviewJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- Drug-Eluting Stent Update 2007Circulation, 2007
- Interleukin-1 receptor antagonist alters the response to vessel wall injury in a porcine coronary artery modelCardiovascular Research, 2005
- Relative importance of the components of stent geometry to stretch induced in-stent neointima formation: Figure 1Heart, 2005
- Response of very small (2 mm) porcine coronary arteries to balloon angioplasty and stent implantationHeart, 2004
- Influence of stent design on 1-year outcome after coronary stent placement: A randomized comparison of five stent types in 1,147 unselected patientsCatheterization and Cardiovascular Interventions, 2000
- Temporal and spatial distribution of interleukin-1β in balloon injured porcine coronary arteriesCardiovascular Research, 1999
- Pigs, Dogs, Baboons, and Man: Lessons for Stenting from Animal StudiesJournal of Interventional Cardiology, 1994