Hannan Tahir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hannan Tahir has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Alfons G. Hoekstra
Computational Science, Informatics Institute, University of Amsterdam, Science Park 904, Amsterdam 1098 XH, The Netherlands
3 shared publications- Carles Bona-Casas
Section Computational Science, University of Amsterdam, The Netherlands
2 shared publications Julian Gunn
Coronary Artery Disease Group, Department of Cardiovascular Science, University of Sheffield, Sheffield, UK
2 shared publications- Andrew James Narracott
University of Sheffield
1 shared publication D. Rodney Hose
Medical Physics Group, Department of Cardiovascular Science, University of Sheffield, Sheffield, UK
1 shared publicationDavid J.W. Evans
Medical Physics Group, Department of Cardiovascular Science, University of Sheffield, Sheffield, UK
1 shared publication
Latest Publications
- Open Access
- 6 May 2014
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 11 (94) , 20140022
Endothelial repair process and its relevance to longitudinal neointimal tissue patterns: comparing histology with in silico modelling
Re-establishing a functional endothelium following endovascular treatment is an important factor in arresting neointimal proliferation. In this study, both histology ( in vivo ) and computational simulations ( in silico ) are used to evaluate neointimal growth patterns within coronary arteries along the axial direction of the stent. Comparison of the growth configurations in vivo and in silico was undertaken to identify candidate mechanisms for endothelial repair. Stent, lumen and neointimal areas were measured from histological sections obtained from eight right coronary stented porcine arteries. Two re-endothelialization scenarios (endothelial cell (EC) random seeding and EC growth from proximal and distal ends) were implemented in silico to evaluate their influence on the morphology of the simulated lesions. Subject to the assumptions made in the current simulations, comparison between in vivo and in silico results suggests that endothelial growth does not occur from the proximal and distal ends alone, but is more consistent with the assumption of a random seeding process. This may occur either from the patches of endothelium which survive following stent implantation or from attachment of circulating endothelial progenitor cells.
- 6 May 2014
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 11 (94) , 20140022
Open AccessEndothelial repair process and its relevance to longitudinal neointimal tissue patterns: comparing histology with in silico modelling
Re-establishing a functional endothelium following endovascular treatment is an important factor in arresting neointimal proliferation. In this study, both histology ( in vivo ) and computational simulations ( in silico ) are used to evaluate neointimal growth patterns within coronary arteries along the axial direction of the stent. Comparison of the growth configurations in vivo and in silico was undertaken to identify candidate mechanisms for endothelial repair. Stent, lumen and neointimal areas were measured from histological sections obtained from eight right coronary stented porcine arteries. Two re-endothelialization scenarios (endothelial cell (EC) random seeding and EC growth from proximal and distal ends) were implemented in silico to evaluate their influence on the morphology of the simulated lesions. Subject to the assumptions made in the current simulations, comparison between in vivo and in silico results suggests that endothelial growth does not occur from the proximal and distal ends alone, but is more consistent with the assumption of a random seeding process. This may occur either from the patches of endothelium which survive following stent implantation or from attachment of circulating endothelial progenitor cells.
- Open Access
- 13 June 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (6) , e66138
Modelling the Effect of a Functional Endothelium on the Development of In-Stent Restenosis
Treatment of stenosed coronary arteries by balloon angioplasty and stenting results in arterial injury including severe damage to the endothelium at the site of treatment and initiates a complex cascade of inflammatory processes that may lead to the development of in-stent restenosis (ISR). Many clinical and biological factors involved in the progression of restenotic lesions have been studied in detail over the past few years but the mystery behind the pathophysiological mechanisms of this disease is still unresolved. In the present work, the effects of re-endothelialization and nitric oxide release on neointimal growth are investigated in-silico using a two dimensional multi-scale model of ISR. The effect of stent deployment depths on the development of ISR is studied as a function of time after stenting. Two dimensional domains were prepared by deploying bare metal stent struts at three different deployment depths into the tissue. Shear stress distribution on endothelial cells, obtained by blood flow simulations, was translated into nitric oxide production that keeps the smooth muscle cells in quiescent state. The cellular growth trends were plotted as a function of time and the data indicate a positive correlation between the neointimal growths and strut deployment depths in the presence of a functional endothelium, in qualitative agreement with in-vivo data. Additionally, no ISR is observed if a functional endothelium appears much earlier.
- 13 June 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (6) , e66138
Open AccessModelling the Effect of a Functional Endothelium on the Development of In-Stent Restenosis
Treatment of stenosed coronary arteries by balloon angioplasty and stenting results in arterial injury including severe damage to the endothelium at the site of treatment and initiates a complex cascade of inflammatory processes that may lead to the development of in-stent restenosis (ISR). Many clinical and biological factors involved in the progression of restenotic lesions have been studied in detail over the past few years but the mystery behind the pathophysiological mechanisms of this disease is still unresolved. In the present work, the effects of re-endothelialization and nitric oxide release on neointimal growth are investigated in-silico using a two dimensional multi-scale model of ISR. The effect of stent deployment depths on the development of ISR is studied as a function of time after stenting. Two dimensional domains were prepared by deploying bare metal stent struts at three different deployment depths into the tissue. Shear stress distribution on endothelial cells, obtained by blood flow simulations, was translated into nitric oxide production that keeps the smooth muscle cells in quiescent state. The cellular growth trends were plotted as a function of time and the data indicate a positive correlation between the neointimal growths and strut deployment depths in the presence of a functional endothelium, in qualitative agreement with in-vivo data. Additionally, no ISR is observed if a functional endothelium appears much earlier.
- Open Access
- 30 March 2011
- Published by The Royal Society in Interface Focus
- Vol. 1 (3) , 365-373
Multi-scale simulations of the dynamics of in-stent restenosis: impact of stent deployment and design
Neointimal hyperplasia, a process of smooth muscle cell re-growth, is the result of a natural wound healing response of the injured artery after stent deployment. Excessive neointimal hyperplasia following coronary artery stenting results in in-stent restenosis (ISR). Regardless of recent developments in the field of coronary stent design, ISR remains a significant complication of this interventional therapy. The influence of stent design parameters such as strut thickness, shape and the depth of strut deployment within the vessel wall on the severity of restenosis has already been highlighted but the detail of this influence is unclear. These factors impact on local haemodynamics and vessel structure and affect the rate of neointima formation. This paper presents the first results of a multi-scale model of ISR. The development of the simulated restenosis as a function of stent deployment depth is compared with an in vivo porcine dataset. Moreover, the influence of strut size and shape is investigated, and the effect of a drug released at the site of injury, by means of a drug-eluting stent, is also examined. A strong correlation between strut thickness and the rate of smooth muscle cell proliferation has been observed. Simulation results also suggest that the growth of the restenotic lesion is strongly dependent on the stent strut cross-sectional profile.
- 30 March 2011
- Published by The Royal Society in Interface Focus
- Vol. 1 (3) , 365-373
Open AccessMulti-scale simulations of the dynamics of in-stent restenosis: impact of stent deployment and design
Neointimal hyperplasia, a process of smooth muscle cell re-growth, is the result of a natural wound healing response of the injured artery after stent deployment. Excessive neointimal hyperplasia following coronary artery stenting results in in-stent restenosis (ISR). Regardless of recent developments in the field of coronary stent design, ISR remains a significant complication of this interventional therapy. The influence of stent design parameters such as strut thickness, shape and the depth of strut deployment within the vessel wall on the severity of restenosis has already been highlighted but the detail of this influence is unclear. These factors impact on local haemodynamics and vessel structure and affect the rate of neointima formation. This paper presents the first results of a multi-scale model of ISR. The development of the simulated restenosis as a function of stent deployment depth is compared with an in vivo porcine dataset. Moreover, the influence of strut size and shape is investigated, and the effect of a drug released at the site of injury, by means of a drug-eluting stent, is also examined. A strong correlation between strut thickness and the rate of smooth muscle cell proliferation has been observed. Simulation results also suggest that the growth of the restenotic lesion is strongly dependent on the stent strut cross-sectional profile.