INVESTIGATION ON THE USE OF FRICKE DOSIMETRY FOR COSMIC RADIATION
Authors:
- Andrea MantuanoAMAndrea Mantuano
- Arissa Pickler OliveiraAOArissa Pickler Oliveira
- Carla Lemos da Silva MotaCMCarla Lemos da Silva Mota
- Camila SalataCSCamila Salata
- Marcelo de Oliveira SouzaMSMarcelo de Oliveira Souza
- Claudete da Conceição SoaresCSClaudete da Conceição Soares
- Carla de Sales PessanhaCPCarla de Sales Pessanha
- Luís Alexandre Gonçalves MagalhãesLMLuís Alexandre Gonçalves Magalhães
Open Access
- 2 October 2023
- journal article
- research article
- Published by Brazilian Journals in REVISTA FOCO
- Vol. 16 (10) , e3282
Abstract
The dosimetry of cosmic radiation outside Earth's atmosphere is a significant challenge due to the high complexity of radiation fields encountered in Low Earth Orbit (LEO) and interplanetary space, in addition to the constraints imposed by instrument spaceflight. The Fricke dosimeter is a water-based (96% by mass) chemical dosimetry system that offers the potential to measure the absorbed dose in water in an arbitrary geometry, for doses of up to 400 Gy, for different energy spectra. The LCR/UERJ was part of the Cubes in Space project. The main goal of this work was to obtain absorbed doses in water at different altitudes in the atmosphere using rocket and balloon systems sent by NASA's space station, using the Fricke dosimeter. For each project, 10 polyethylene bags with the Fricke dosimeter were made. The dosimeters were sent on a 20-cubic-meter helium balloon to a target altitude of at least 36.5 km, where they experienced conditions close to space. The average dose in the Fricke solution in the balloon was 9.3 ± 1.5 Gy and in the rocket was 20.4 ± 1.4 Gy. The maximum altitude reached by the balloon is 36.5 km, with a flight duration of approximately 12 hours. On the other hand, the rocket reaches a maximum altitude of 120 km, but it remains in flight for only a few minutes. The 54% difference in the absorbed dose can be explained by the different particles that are responsible for the cosmic radiation in different altitudes. Cosmic radiation increases with altitude in the atmosphere and can vary from hour to hour. The Fricke dosimeter has proven to be effective for aerospace dosimetry, as it was utilized according to the presented boundary conditions. Gathering more technical flight information can lead to future results with greater precision and lower uncertainties.Keywords
This publication has 18 references indexed in Scilit:
- Cosmic radiation dose measurements from the RaD-X flight campaignSpace Weather, 2016
- SU-F-BRA-10: Fricke Dosimetry: Determination of the G-Value for Ir-192 Energy Based On the NRC MethodologyMedical Physics, 2015
- Avaliação da contribuição dos diferentes componentes da radiação cósmica atmosférica na dose em tripulações de aeronavesBrazilian Journal of Radiation Sciences, 2015
- A Feasibility Study of Fricke Dosimetry as an Absorbed Dose to Water Standard for 192Ir HDR SourcesPLOS ONE, 2014
- Space radiation dosimetry in low-Earth orbit and beyondNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2001
- Fricke dosimetry: the difference betweenG(Fe3+) for60Co gamma-rays and high-energy x-raysPhysics in Medicine & Biology, 1999
- Measurement of ferric ion concentration in the Fricke dosemeterPhysics in Medicine & Biology, 1971
- Ferrous sulphate G-values for X-rays of 'effective' energy 48 and 25 keVPhysics in Medicine & Biology, 1969
- The Measurement of Low Energy X-Rays III: Ferrous Sulphate G-ValuesPhysics in Medicine & Biology, 1968
- Practical Aspects of Ferrous Sulphate DosimetryPhysics in Medicine & Biology, 1963