Andrea Mantuano has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fricke Chemical Dosimeter

    by Andrea Mantuano, Claudiu Cojocaru, Carl Ross, Carlos Eduardo De Almeida, Camila Salata

  • Open Access

    Effect of the initiation and duration of physical exercise on the deleterious effects induced by ionizing radiation on the brain

    by Luciana P.M. Teixeira, Cláudio Sérgio C. Lau, Eduardo M. Nogueira, Giselle O.G. Cassimiro, André R.C. Barreto-Vianna, Roberto Salomão DE Souza, Andrea Mantuano, Bianca T. Ciambarella, Maurício Moacir S. Borges, Jhon Brandon Félix Ferreira, et al.

    Radiotherapy can damage healthy brain tissue, leading to cognitive deficits. Physical exercise enhances neurogenesis and synaptic plasticity, improving cognitive functions like memory and learning. This study evaluated aerobic exercise’s effect on endothelial marker gene expression and memory in cranially irradiated mice. In total, 144 male Swiss mice were divided into sedentary control (SC), sedentary irradiated (SI), exercise control (EC), and irradiated exercise (EI) groups. The EI groups underwent treadmill training in three conditions: 3-months post-irradiation, 1-month pre-irradiation, and 1- month post-irradiation. Ninety days after irradiation, memory was tested using the open- field and object location memory tests. RT-qPCR analyzed hippocampal expression of VEGF-A, eNOS, and vWF. No differences were found in the open-field test, but sedentary irradiated mice showed impaired memory in the object location task. Treadmill training restored memory, especially in the 3-month post-irradiation group. Irradiation increased vWF expression, which physical exercise mitigated. Physical activity also increased VEGF-A and eNOS expression in irradiated mice. These findings suggest that post-irradiation exercise mitigates memory impairment and may influence vascular changes in the brain.


  • Determination of the Fricke dosimetry chemical yield, G(Fe3 +), for different low- and medium-energy qualities of X-ray beams and gamma sources

    by Camila Salata, Mariano David, Andrea Mantuano, Carla Mota, Arissa Pickler, Paulo Henrique Rosado, Carlos E. de Almeida


  • Open Access

    INVESTIGATION ON THE USE OF FRICKE DOSIMETRY FOR COSMIC RADIATION

    by Andrea Mantuano, Arissa Pickler Oliveira, Carla Lemos da Silva Mota, Camila Salata, Marcelo de Oliveira Souza, Claudete da Conceição Soares, Carla de Sales Pessanha, Luís Alexandre Gonçalves Magalhães

    The dosimetry of cosmic radiation outside Earth's atmosphere is a significant challenge due to the high complexity of radiation fields encountered in Low Earth Orbit (LEO) and interplanetary space, in addition to the constraints imposed by instrument spaceflight. The Fricke dosimeter is a water-based (96% by mass) chemical dosimetry system that offers the potential to measure the absorbed dose in water in an arbitrary geometry, for doses of up to 400 Gy, for different energy spectra. The LCR/UERJ was part of the Cubes in Space project. The main goal of this work was to obtain absorbed doses in water at different altitudes in the atmosphere using rocket and balloon systems sent by NASA's space station, using the Fricke dosimeter. For each project, 10 polyethylene bags with the Fricke dosimeter were made. The dosimeters were sent on a 20-cubic-meter helium balloon to a target altitude of at least 36.5 km, where they experienced conditions close to space. The average dose in the Fricke solution in the balloon was 9.3 ± 1.5 Gy and in the rocket was 20.4 ± 1.4 Gy. The maximum altitude reached by the balloon is 36.5 km, with a flight duration of approximately 12 hours. On the other hand, the rocket reaches a maximum altitude of 120 km, but it remains in flight for only a few minutes. The 54% difference in the absorbed dose can be explained by the different particles that are responsible for the cosmic radiation in different altitudes. Cosmic radiation increases with altitude in the atmosphere and can vary from hour to hour. The Fricke dosimeter has proven to be effective for aerospace dosimetry, as it was utilized according to the presented boundary conditions. Gathering more technical flight information can lead to future results with greater precision and lower uncertainties.

  • Preliminary pre-clinical studies on the side effects of breast cancer treatment

    by Camila Salata, Carlos E. Dealmeida, Samara C. Ferreira-Machado, Regina C. Barroso, Liebert P. Nogueira, Andrea Mantuano, Arissa Pickler, Carla L. Mota, Cherley B. V. de Andrade

    Purpose: Technological advancement in the treatment of cancer together with early detection and diagnosis have considerably improved the survival of breast cancer patients. On the other hand, the potential of patients developing side effects from cancer treatment are not negligible. Despite the progress that has been made in terms of early diagnosis, therapy, and survival, including improvements in the chemotherapeutic agents, radiation and molecular targeted therapies, cardiotoxicity of cancer therapy is still cause for concern. Radiation therapy for breast cancer is associated with increased risk of heart disease and myocardial infarction. Furthermore, the association of radiation therapy to chemotherapy is an important aspect to be considered in the development of cardiac disease, as this could play an additional role as a risk factor. Besides the heart effect, other side effects can be observed in the bone, ovary, uteri, and other organs. This paper aims to review the recent literature to present the current understanding of side effects associated with breast cancer treatment. The focus is on recent preclinical studies that have assessed potential changes in different organs that may be injured after breast cancer treatment, both due to both radiation and chemotherapy agents. Conclusion: Radiation-induced heart disease is one important side effect that must be considered during the treatment planning and patient follow-up. The cardiac damage can be potentialized when chemotherapy is associated to radiotherapy, and the literature findings indicate that heart fibrosis plays an important role at the radio-chemotherapy induced cardiac damage. Literature findings also showed important side effects at the bone, that can lead to ospeoporosis, due to the decrease of calcium, after radio or chemotherapy treatments. This decrease could be explained by the ovarian failure observed at rats after chemotherapy treatment. It is of great importance to acknowledge the complications originating from the treatment, so that new strategies can be developed. In this way, it will be possible to minimize side effects and improve the patients’ quality of life.


  • A pilot study of a postal dosimetry system using the Fricke dosimeter for research irradiators

    by Andrea Mantuano, Carla Lemos Mota, Camila Salata, Arissa Pickler, Luis Alexandre Gonçalves Magalhães, Carlos E. de Almeida


  • Technical Note: Fricke dosimetry for blood irradiators

    by Andrea Mantuano, Camila Salata, Carla Lemos Mota, Arissa Pickler, Leonardo de Castro Pacífico, Luís Alexandre Gonçalves Magalhães, Carlos Eduardo de Almeida

    Purpose The Fricke dosimeter has been shown to be a viable option as an absorbed dose standard. The present work aims to provide the dose distribution in an irradiator container during blood irradiation using Fricke dosimetry. Methods Measurements were performed using a Gammacell Elan 3000 blood irradiator at Hemocenter in Rio de Janeiro, Brazil. A specific phantom was constructed and patented by the authors to perform these measurements. Fricke solution was prepared according to international protocols, and polyethylene bags filled with Fricke solution (n=19) were spatially distributed within the phantom. Control bags were also submitted to the same process, except the irradiation. The irradiation time was calculated to give 25.7 Gy to the central portion of the phantom, the same dose used for blood bags. Results Encouraging results were obtained with an overall uncertainty of 2.1% (k=1). The obtained results were compared with the doses calculated by the physicist from Hemocenter based on parameters provided by the manufacturer. The mean dose delivered to the Fricke bag in the center of the phantom (cavity 2) was 28.7 ± 0.5 Gy, which is 12% higher than the planned dose of 25.7 Gy. Conclusions The obtained results showed that the setup (Fricke and phantom) is able to perform dosimetry for blood irradiators. The delivered dose was higher than expected. This highlights the importance in controlling all the parameters during irradiation to ensure the correct dose for all irradiated bags.


  • Elemental distribution in ascending aortic after radiotherapy and chemotherapy by Low Energy X-ray Fluorescence spectroscopy

    by A. Mantuano, C.L. Mota, A. Pickler, G. Sena, D. Braz, C. Salata, C.E. de Almeida, F.N. Costa, R.C. Barroso

    Breast cancer (BC) is the most frequent cancer and the leading cause of cancer-related mortality in women. The treatment techniques for the BC include chemotherapy (CT) and/or radiotherapy (RT) and can modify elementary the cell matrix by calcificating tissues due to biological and morphological changes. Also, treatments for BC induce cardiotoxicity and it is important to understand the mechanisms involved in order to prevent this late effect in treated breast cancer patients. The high incidence of cardiovascular mortality in breast cancer patients is partially credited to increased intimal and medial calcifications of the aorta. The aim of this work is to investigate the distibution of low atomic number elements such as Magnesium (Mg), due to its importance for the cardiac metabolism; iron (Fe), since BC treatment may be associated with oxidative stress; and Sodium (Na), that is extremely related to the damage of endothelial cells. An optimal technique to observe these changes in aorta tissue is soft X-ray FLuorescence that can provide elemental maps of these important elements. The results performed by Low Energy X-ray Fluorescence LEXRF analyses showed that when the tissue is submitted to treatments with CT and/or RT, some normal structures become disorganized, and consequently the intensity of elemental compounds can be changed. All the experiments were carried out at the TwinMic beamline at Elettra Synchrotron facility using as animal model Wistar rats in order to evaluate the distribution of Na, Mg and Fe in aorta walls of Wistar rats, after BC treatment. Simultaneous acquisition of LEXRF and attenuation coefficient maps suggest that the combined chemotherapy and radiotherapy caused more damage to the aortic tissue as compared to radiation therapy alone. These findings add an in-depth understanding of elemental lack or excess in the tissue and contribute to locate these changes.


  • Effects of soft X-ray radiation damage on paraffin-embedded rat tissues supported on ultralene: a chemical perspective

    by Diana E. Bedolla, Andrea Mantuano, Arissa Pickler, Carla Lemos Mota, Delson Braz, Camila Salata, Carlos Eduardo Almeida, Giovanni Birarda, Lisa Vaccari, Regina Cély Barroso, et al.

    Radiation damage is an important aspect to be considered when analysing biological samples with X-ray techniques as it can induce chemical and structural changes in the specimens. This work aims to provide new insights into the soft X-ray induced radiation damage of the complete sample, including not only the biological tissue itself but also the substrate and embedding medium, and the tissue fixation procedure. Sample preparation and handling involves an unavoidable interaction with the sample matrix and could play an important role in the radiation-damage mechanism. To understand the influence of sample preparation and handling on radiation damage, the effects of soft X-ray exposure at different doses on ultralene, paraffin and on paraffin-embedded rat tissues were studied using Fourier-transform infrared (FTIR) microspectroscopy and X-ray microscopy. Tissues were preserved with three different commonly used fixatives: formalin, glutaraldehyde and Karnovsky. FTIR results showed that ultralene and paraffin undergo a dose-dependent degradation of their vibrational profiles, consistent with radiation-induced oxidative damage. In addition, formalin fixative has been shown to improve the preservation of the secondary structure of proteins in tissues compared with both glutaraldehyde and Karnovsky fixation. However, conclusive considerations cannot be drawn on the optimal fixation protocol because of the interference introduced by both substrate and embedding medium in the spectral regions specific to tissue lipids, nucleic acids and carbohydrates. Notably, despite the detected alterations affecting the chemical architecture of the sample as a whole, composed of tissue, substrate and embedding medium, the structural morphology of the tissues at the micrometre scale is essentially preserved even at the highest exposure dose.


  • Open Access

    Linearity and reproducibility response of Fricke dosimetry for low energy X-Ray beam

    by A Mantuano, G J de Amorim, M G David, P H G Rosado, C Salata, L A G Magalhães, C E Dealmeida

    The Fricke dosimeter is the most used, liquid chemical dosimeter. It has been shown to be a feasible option for the absorbed dose standard. The present work aims to determinate a dose-response curve of Fricke solution using different doses and reproducibility test comparing the calculated dose to Fricke solution and Ionizing Chamber. Tests were performed using an X-ray irradiator for biological research at Radiological Science Laboratory (LCR/UERJ). The results showed a linear response to different doses of type A uncertainties from 0.08 to 1.2%. Reproducibility test showed type A uncertainties of 0.16% to the dosimeter.