Clinical value of the 70-kVp ultra-low-dose CT pulmonary angiography with deep learning image reconstruction
Authors:
- 2 July 2025
- journal article
- computed tomography
- Published by Springer Nature in European Radiology
- Vol. 36 (1) , 564-574
Abstract
Objective This study aims to assess the feasibility of “double-low,” low radiation dosage and low contrast media dosage, CT pulmonary angiography (CTPA) based on deep-learning image reconstruction (DLIR) algorithms. Materials and methods One hundred consecutive patients (41 females; average age 60.9 years, range 18–90) were prospectively scanned on multi-detector CT systems. Fifty patients in the conventional-dose group (CD group) underwent CTPA with 100 kV protocol using the traditional iterative reconstruction algorithm, and 50 patients in the low-dose group (LD group) underwent CTPA with a 70 kVp DLIR protocol. Radiation and contrast agent doses were recorded and compared between groups. Objective parameters were measured and compared. Two radiologists evaluated images for overall image quality, artifacts, and image contrast separately on a 5-point scale. The furthest visible branches were compared between groups. Results Compared to the control group, the study group reduced the dose-length product by 80.3% (p < 0.01) and the contrast media dose by 33.3%. CT values, SD values, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) showed no statistically significant differences (all p > 0.05) between the LD and CD groups. The overall image quality scores were comparable between the LD and CD groups (p > 0.05), with good in-reader agreement (k = 0.75). More peripheral pulmonary vessels could be assessed in the LD group compared with the CD group. Conclusion 70 kVp combined with DLIR reconstruction for CTPA can further reduce radiation and contrast agent dose while maintaining image quality and increasing the visibility on the pulmonary artery distal branches. Key Points Question Elevated radiation exposure and substantial doses of contrast media during CT pulmonary angiography (CTPA) augment patient risks. Findings The “double-low” CT pulmonary angiography protocol can diminish radiation doses by 80.3% and minimize contrast doses by one-third while maintaining image quality. Clinical relevance With deep learning algorithms, we confirmed that CTPA images maintained excellent quality despite reduced radiation and contrast dosages, helping to reduce radiation exposure and kidney burden on patients. The “double-low” CTPA protocol, complemented by deep learning image reconstruction, prioritizes patient safety. Graphical AbstractKeywords
Funding Information
- the Science and Technology Research Project of Henan Provincial Health Commission (No.212102310142)
This publication has 33 references indexed in Scilit:
- Deep learning reconstruction algorithm and high-concentration contrast medium: feasibility of a double-low protocol in coronary computed tomography angiographyEuropean Radiology, 2024
- CT and X-ray contrast agents: Current clinical challenges and the future of contrastActa Biomaterialia, 2023
- Deep learning image reconstruction to improve accuracy of iodine quantification and image quality in dual-energy CT of the abdomen: a phantom and clinical studyEuropean Radiology, 2022
- High-strength deep learning image reconstruction in coronary CT angiography at 70-kVp tube voltage significantly improves image quality and reduces both radiation and contrast dosesEuropean Radiology, 2022
- Dose reduction potential of vendor-agnostic deep learning model in comparison with deep learning–based image reconstruction algorithm on CT: a phantom studyEuropean Radiology, 2021
- Performance evaluation of a deep learning image reconstruction (DLIR) algorithm in “double low” chest CTA in children: a feasibility studyLa radiologia medica, 2021
- Contrast-induced acute kidney injuryCardiovascular Intervention and Therapeutics, 2020
- Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: a comparative studyEuropean Radiology, 2020
- Reducing Radiation Dose and Improving Image Quality in CT Portal Venography Using 80 kV and Adaptive Statistical Iterative Reconstruction-V in Slender PatientsAcademic Radiology, 2020
- Deep Learning Reconstruction at CT: Phantom Study of the Image CharacteristicsAcademic Radiology, 2020