Jie Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jie Liu has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Jianbo Gao
The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan 450052, China (K.Q., S.L., J.Z., X.W., P.H., D.Y., Y.Z., A.D., Q.T., M.Z., W.Z., J.G., J.L.).
12 shared publicationsDian Yuan
The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan 450052, China (K.Q., S.L., J.Z., X.W., P.H., D.Y., Y.Z., A.D., Q.T., M.Z., W.Z., J.G., J.L.).
9 shared publicationsYicun Zhang
The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan 450052, China (K.Q., S.L., J.Z., X.W., P.H., D.Y., Y.Z., A.D., Q.T., M.Z., W.Z., J.G., J.L.).
9 shared publicationsMengyuan Zhang
The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan 450052, China (K.Q., S.L., J.Z., X.W., P.H., D.Y., Y.Z., A.D., Q.T., M.Z., W.Z., J.G., J.L.).
8 shared publicationsWeiting Zhang
The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan 450052, China (K.Q., S.L., J.Z., X.W., P.H., D.Y., Y.Z., A.D., Q.T., M.Z., W.Z., J.G., J.L.).
7 shared publicationsKe Qi
The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan 450052, China (K.Q., S.L., J.Z., X.W., P.H., D.Y., Y.Z., A.D., Q.T., M.Z., W.Z., J.G., J.L.).
6 shared publications
Latest Publications
- 30 May 2026
- Published by Elsevier in Academic Radiology
- Vol. 33 (8) , 3373-3383
Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in High-BMI Patients
- 30 May 2026
- Published by Elsevier in Academic Radiology
- Vol. 33 (8) , 3373-3383
Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in High-BMI Patients
- 1 January 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 318 (1) , e251609
Ultra-Low-Dose Photon-counting Detector CT for Emphysema Assessment: A Head-to-Head Comparative Study with Low-Dose CT
Ultra-low-dose photon-counting CT provided comparable diagnostic performance to low-dose CT for emphysema, enabling reliable visual and quantitative assessment, with radiation exposure similar to that of two standard chest radiographs.
- 1 January 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 318 (1) , e251609
Ultra-Low-Dose Photon-counting Detector CT for Emphysema Assessment: A Head-to-Head Comparative Study with Low-Dose CT
Ultra-low-dose photon-counting CT provided comparable diagnostic performance to low-dose CT for emphysema, enabling reliable visual and quantitative assessment, with radiation exposure similar to that of two standard chest radiographs.
- 1 December 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 7 (6) , e240495
Evaluation on the Feasibility of the Pulse Oximetry–triggered Coronary CT Angiography
Pulse oximetry–triggered coronary CT angiography (CCTA) on a 16-cm z-axis coverage CT with motion correction and deep learning image reconstruction algorithms showed comparable image quality at equivalent radiation and contrast doses as conventional CCTA while significantly reducing examination time.
- 1 December 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 7 (6) , e240495
Evaluation on the Feasibility of the Pulse Oximetry–triggered Coronary CT Angiography
Pulse oximetry–triggered coronary CT angiography (CCTA) on a 16-cm z-axis coverage CT with motion correction and deep learning image reconstruction algorithms showed comparable image quality at equivalent radiation and contrast doses as conventional CCTA while significantly reducing examination time.
- Open Access
- 1 November 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (11) , 10795-10807
Deep learning-based bone removal in head and neck computed tomography angiography: a comparative study with conventional algorithms
Background: The adjacent bones and vessels in complex anatomic regions presented diagnostic challenges, especially in head and neck computed tomography angiography (CTA). It requires more accurate removal of bones for clinical routine diagnosis, which couldn’t be fully satisfied with conventional bone removal techniques. This study aims to evaluate the performance of a novel deep learning-based bone removal algorithm compared to a conventional method in head and neck CTA, focusing on image quality and radiation dose optimization across two tube voltage settings (100 and 120 kVp). Methods: In a single-center randomized controlled trial (RCT) (February to March 2024), 119 consecutive patients [median age, 57 years; interquartile range (IQR), 50–65 years] suspected of cerebrovascular disease underwent head and neck CTA on a dual-source computed tomography (CT) scanner. Patients were randomized to 100 kVp (n=58) or 120 kVp (n=61) groups. Images were processed using a conventional threshold-based algorithm and a convolutional neural network (CNN)-based deep learning algorithm, which was trained on a dataset of 1,014 annotated CTA images. Two blinded radiologists assessed image quality (bone removal effectiveness, vessel branch completeness, whole vessel completeness) with a 5-point Likert scale. Radiation dose was recorded with CT dose index volume (CTDIvol) and dose-length product (DLP). Statistical analysis was performed with Wilcoxon signed-rank tests, Mann-Whitney U tests, and multivariate regression, and PResults: The image quality of deep learning algorithm significantly outperformed that of conventional method across all metrics (Pvs. 12.5±1.2 mGy, P0.05). Conclusions: The CNN-based bone removal algorithm enhances vascular visualization in head and neck CTA, particularly at 100 kVp, offering superior segmentation accuracy even at lower radiation dose. These findings advocate for its integration into clinical workflows to improve cerebrovascular diagnostics.
- 1 November 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (11) , 10795-10807
Open AccessDeep learning-based bone removal in head and neck computed tomography angiography: a comparative study with conventional algorithms
Background: The adjacent bones and vessels in complex anatomic regions presented diagnostic challenges, especially in head and neck computed tomography angiography (CTA). It requires more accurate removal of bones for clinical routine diagnosis, which couldn’t be fully satisfied with conventional bone removal techniques. This study aims to evaluate the performance of a novel deep learning-based bone removal algorithm compared to a conventional method in head and neck CTA, focusing on image quality and radiation dose optimization across two tube voltage settings (100 and 120 kVp). Methods: In a single-center randomized controlled trial (RCT) (February to March 2024), 119 consecutive patients [median age, 57 years; interquartile range (IQR), 50–65 years] suspected of cerebrovascular disease underwent head and neck CTA on a dual-source computed tomography (CT) scanner. Patients were randomized to 100 kVp (n=58) or 120 kVp (n=61) groups. Images were processed using a conventional threshold-based algorithm and a convolutional neural network (CNN)-based deep learning algorithm, which was trained on a dataset of 1,014 annotated CTA images. Two blinded radiologists assessed image quality (bone removal effectiveness, vessel branch completeness, whole vessel completeness) with a 5-point Likert scale. Radiation dose was recorded with CT dose index volume (CTDIvol) and dose-length product (DLP). Statistical analysis was performed with Wilcoxon signed-rank tests, Mann-Whitney U tests, and multivariate regression, and PResults: The image quality of deep learning algorithm significantly outperformed that of conventional method across all metrics (Pvs. 12.5±1.2 mGy, P0.05). Conclusions: The CNN-based bone removal algorithm enhances vascular visualization in head and neck CTA, particularly at 100 kVp, offering superior segmentation accuracy even at lower radiation dose. These findings advocate for its integration into clinical workflows to improve cerebrovascular diagnostics.
- 2 July 2025
- Published by Springer Nature in European Radiology
- Vol. 36 (1) , 564-574
Clinical value of the 70-kVp ultra-low-dose CT pulmonary angiography with deep learning image reconstruction
Objective This study aims to assess the feasibility of “double-low,” low radiation dosage and low contrast media dosage, CT pulmonary angiography (CTPA) based on deep-learning image reconstruction (DLIR) algorithms. Materials and methods One hundred consecutive patients (41 females; average age 60.9 years, range 18–90) were prospectively scanned on multi-detector CT systems. Fifty patients in the conventional-dose group (CD group) underwent CTPA with 100 kV protocol using the traditional iterative reconstruction algorithm, and 50 patients in the low-dose group (LD group) underwent CTPA with a 70 kVp DLIR protocol. Radiation and contrast agent doses were recorded and compared between groups. Objective parameters were measured and compared. Two radiologists evaluated images for overall image quality, artifacts, and image contrast separately on a 5-point scale. The furthest visible branches were compared between groups. Results Compared to the control group, the study group reduced the dose-length product by 80.3% (p < 0.01) and the contrast media dose by 33.3%. CT values, SD values, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) showed no statistically significant differences (all p > 0.05) between the LD and CD groups. The overall image quality scores were comparable between the LD and CD groups (p > 0.05), with good in-reader agreement (k = 0.75). More peripheral pulmonary vessels could be assessed in the LD group compared with the CD group. Conclusion 70 kVp combined with DLIR reconstruction for CTPA can further reduce radiation and contrast agent dose while maintaining image quality and increasing the visibility on the pulmonary artery distal branches. Key Points Question Elevated radiation exposure and substantial doses of contrast media during CT pulmonary angiography (CTPA) augment patient risks. Findings The “double-low” CT pulmonary angiography protocol can diminish radiation doses by 80.3% and minimize contrast doses by one-third while maintaining image quality. Clinical relevance With deep learning algorithms, we confirmed that CTPA images maintained excellent quality despite reduced radiation and contrast dosages, helping to reduce radiation exposure and kidney burden on patients. The “double-low” CTPA protocol, complemented by deep learning image reconstruction, prioritizes patient safety. Graphical Abstract
- 2 July 2025
- Published by Springer Nature in European Radiology
- Vol. 36 (1) , 564-574
Clinical value of the 70-kVp ultra-low-dose CT pulmonary angiography with deep learning image reconstruction
Objective This study aims to assess the feasibility of “double-low,” low radiation dosage and low contrast media dosage, CT pulmonary angiography (CTPA) based on deep-learning image reconstruction (DLIR) algorithms. Materials and methods One hundred consecutive patients (41 females; average age 60.9 years, range 18–90) were prospectively scanned on multi-detector CT systems. Fifty patients in the conventional-dose group (CD group) underwent CTPA with 100 kV protocol using the traditional iterative reconstruction algorithm, and 50 patients in the low-dose group (LD group) underwent CTPA with a 70 kVp DLIR protocol. Radiation and contrast agent doses were recorded and compared between groups. Objective parameters were measured and compared. Two radiologists evaluated images for overall image quality, artifacts, and image contrast separately on a 5-point scale. The furthest visible branches were compared between groups. Results Compared to the control group, the study group reduced the dose-length product by 80.3% (p < 0.01) and the contrast media dose by 33.3%. CT values, SD values, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) showed no statistically significant differences (all p > 0.05) between the LD and CD groups. The overall image quality scores were comparable between the LD and CD groups (p > 0.05), with good in-reader agreement (k = 0.75). More peripheral pulmonary vessels could be assessed in the LD group compared with the CD group. Conclusion 70 kVp combined with DLIR reconstruction for CTPA can further reduce radiation and contrast agent dose while maintaining image quality and increasing the visibility on the pulmonary artery distal branches. Key Points Question Elevated radiation exposure and substantial doses of contrast media during CT pulmonary angiography (CTPA) augment patient risks. Findings The “double-low” CT pulmonary angiography protocol can diminish radiation doses by 80.3% and minimize contrast doses by one-third while maintaining image quality. Clinical relevance With deep learning algorithms, we confirmed that CTPA images maintained excellent quality despite reduced radiation and contrast dosages, helping to reduce radiation exposure and kidney burden on patients. The “double-low” CTPA protocol, complemented by deep learning image reconstruction, prioritizes patient safety. Graphical Abstract
- 7 June 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (12) , 7963-7974
Patient-tailored versus fixed post-trigger delay for optimized scan timing: a comparison of image quality and diagnostic confidence in run-off CT angiography
Objectives This study aimed to validate bolus tracking using a patient-tailored post-trigger delay (PTD) in run-off computed tomography angiography (CTA) and to compare the resulting image quality and diagnostic confidence with those obtained using a fixed PTD. Materials and methods Participants were prospectively assigned to either fixed (10 s) or patient-tailored cohorts. We measured attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) for each vascular segment. Two radiologists evaluated qualitative image quality and diagnostic confidence. Differences in quantitative variables between cohorts were assessed using Student’s t-test or Mann–Whitney U test, while categorical variables were assessed using chi-square test. Generalized least squares linear regression was used to evaluate the effects of different cohorts, anatomical locations, and their interactions on attenuation. Results The patient-tailored cohort showed significantly higher attenuation from the popliteal artery to the foot artery (all p < 0.001), with a patient-tailored PTD ranging from 8.10 to 14.90 s. Generalized least squares linear regression revealed more uniform attenuation in patient-tailored cohort and decreasing attenuation in fixed cohort (decrease of 89.06 HU in foot artery, p < 0.001). There was no significant difference in image noise between cohorts (p = 0.060), while SNR and CNR were higher in the patient-tailored cohort at most measurement locations (all p < 0.05). Both radiologists rated the patient-tailored cohort as having better qualitative image quality and more segment with unrestricted diagnostic confidence. Conclusions Bolus tracking with patient-tailored PTD provides reliable scan timing, resulting in optimized vessel opacification, improved image quality, and enhanced diagnostic confidence in run-off CTA. Key Points Question Is this novel bolus tracking algorithm for run-off CT angiography feasible for improving image quality by automatically predicting patient-tailored post-trigger delay (PTD) through real-time monitoring. Findings Patient-tailored PTD improved image quality and distal artery opacification through reliable scan timing, thereby enhancing diagnostic confidence. Clinical relevance Patient-tailored PTD improved image quality, not only demonstrating the potential for reducing contrast media volume but also eliminating the need for compensatory scans from the feet to the knee, thus minimizing additional radiation exposure. Graphical Abstract
- 7 June 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (12) , 7963-7974
Patient-tailored versus fixed post-trigger delay for optimized scan timing: a comparison of image quality and diagnostic confidence in run-off CT angiography
Objectives This study aimed to validate bolus tracking using a patient-tailored post-trigger delay (PTD) in run-off computed tomography angiography (CTA) and to compare the resulting image quality and diagnostic confidence with those obtained using a fixed PTD. Materials and methods Participants were prospectively assigned to either fixed (10 s) or patient-tailored cohorts. We measured attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) for each vascular segment. Two radiologists evaluated qualitative image quality and diagnostic confidence. Differences in quantitative variables between cohorts were assessed using Student’s t-test or Mann–Whitney U test, while categorical variables were assessed using chi-square test. Generalized least squares linear regression was used to evaluate the effects of different cohorts, anatomical locations, and their interactions on attenuation. Results The patient-tailored cohort showed significantly higher attenuation from the popliteal artery to the foot artery (all p < 0.001), with a patient-tailored PTD ranging from 8.10 to 14.90 s. Generalized least squares linear regression revealed more uniform attenuation in patient-tailored cohort and decreasing attenuation in fixed cohort (decrease of 89.06 HU in foot artery, p < 0.001). There was no significant difference in image noise between cohorts (p = 0.060), while SNR and CNR were higher in the patient-tailored cohort at most measurement locations (all p < 0.05). Both radiologists rated the patient-tailored cohort as having better qualitative image quality and more segment with unrestricted diagnostic confidence. Conclusions Bolus tracking with patient-tailored PTD provides reliable scan timing, resulting in optimized vessel opacification, improved image quality, and enhanced diagnostic confidence in run-off CTA. Key Points Question Is this novel bolus tracking algorithm for run-off CT angiography feasible for improving image quality by automatically predicting patient-tailored post-trigger delay (PTD) through real-time monitoring. Findings Patient-tailored PTD improved image quality and distal artery opacification through reliable scan timing, thereby enhancing diagnostic confidence. Clinical relevance Patient-tailored PTD improved image quality, not only demonstrating the potential for reducing contrast media volume but also eliminating the need for compensatory scans from the feet to the knee, thus minimizing additional radiation exposure. Graphical Abstract
- Open Access
- 1 January 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (1) , 709-720
Optimized contrast enhancement and homogeneity in aortic CT angiography: bolus tracking with personalized post-trigger delay
Background: The bolus tracking technique has been used for decades, yet still faces the challenging task of determining the optimal scanning time for individuals. Our study aimed to assess the feasibility of a novel bolus tracking method with a personalized post-trigger delay (PTD) to optimize scanning time and achieve optimized enhancement and contrast homogeneity in aortic computed tomography angiography (CTA). Methods: Participants undergoing aortic CTA with bolus tracking were prospectively assigned to two different groups: Group A with a fixed 6-second PTD and Group B with a personalized PTD. A reader assessed objective image quality and evaluated enhancement level and contrast homogeneity; two readers rated subjective image quality. Student’s t-test or Mann-Whitney U test was used to determine quantitative data, whereas the Chi-square test compared categorical variables between the two groups. Results: Group A comprised 70 participants [13 female; mean ± standard deviation (SD) age 58±11 years], whereas Group B included 70 participants (18 female, mean ± SD age 59±12 years) with the personalized PTD ranging from 7.8 to 14.1 seconds (mean ± SD, 11.2±1.5 seconds). Group B demonstrated improved mean attenuation and contrast-to-noise ratio (CNR) of aortoiliac artery [417.55±71.55 vs. 345.71±60.41 Hounsfield units (HU), 16 vs. 13, both Pvs. 37.1%, Pvs. 64.3%, Pvs. 68.6%, Pvs. 23.3%, PConclusions: Bolus tracking with a personalized PTD can improve enhancement level and contrast homogeneity in aortic CTA due to reliable scan timing.
- 1 January 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (1) , 709-720
Open AccessOptimized contrast enhancement and homogeneity in aortic CT angiography: bolus tracking with personalized post-trigger delay
Background: The bolus tracking technique has been used for decades, yet still faces the challenging task of determining the optimal scanning time for individuals. Our study aimed to assess the feasibility of a novel bolus tracking method with a personalized post-trigger delay (PTD) to optimize scanning time and achieve optimized enhancement and contrast homogeneity in aortic computed tomography angiography (CTA). Methods: Participants undergoing aortic CTA with bolus tracking were prospectively assigned to two different groups: Group A with a fixed 6-second PTD and Group B with a personalized PTD. A reader assessed objective image quality and evaluated enhancement level and contrast homogeneity; two readers rated subjective image quality. Student’s t-test or Mann-Whitney U test was used to determine quantitative data, whereas the Chi-square test compared categorical variables between the two groups. Results: Group A comprised 70 participants [13 female; mean ± standard deviation (SD) age 58±11 years], whereas Group B included 70 participants (18 female, mean ± SD age 59±12 years) with the personalized PTD ranging from 7.8 to 14.1 seconds (mean ± SD, 11.2±1.5 seconds). Group B demonstrated improved mean attenuation and contrast-to-noise ratio (CNR) of aortoiliac artery [417.55±71.55 vs. 345.71±60.41 Hounsfield units (HU), 16 vs. 13, both Pvs. 37.1%, Pvs. 64.3%, Pvs. 68.6%, Pvs. 23.3%, PConclusions: Bolus tracking with a personalized PTD can improve enhancement level and contrast homogeneity in aortic CTA due to reliable scan timing.
- 13 November 2024
- Published by Elsevier in Academic Radiology
- Vol. 32 (3) , 1506-1516
Feasibility of Ultra-low Radiation and Contrast Medium Dosage in Aortic CTA Using Deep Learning Reconstruction at 60 kVp: An Image Quality Assessment
- 13 November 2024
- Published by Elsevier in Academic Radiology
- Vol. 32 (3) , 1506-1516
Feasibility of Ultra-low Radiation and Contrast Medium Dosage in Aortic CTA Using Deep Learning Reconstruction at 60 kVp: An Image Quality Assessment
- 9 May 2024
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 40 (6) , 1-12
Evaluation of image quality on low contrast media with deep learning image reconstruction algorithm in prospective ECG-triggering coronary CT angiography
To assess the impact of low-dose contrast media (CM) injection protocol with deep learning image reconstruction (DLIR) algorithm on image quality in coronary CT angiography (CCTA). In this prospective study, patients underwent CCTA were prospectively and randomly assigned to three groups with different contrast volume protocols (at 320mgI/mL concentration and constant flow rate of 5ml/s). After pairing basic information, 210 patients were enrolled in this study: Group A, 0.7mL/kg (n = 70); Group B, 0.6mL/kg (n = 70); Group C, 0.5mL/kg (n = 70). All patients were examined via a prospective ECG-triggered scan protocol within one heartbeat. A high level DLIR (DLIR-H) algorithm was used for image reconstruction with a thickness and interval of 0.625mm. The CT values of ascending aorta (AA), descending aorta (DA), three main coronary arteries, pulmonary artery (PA), and superior vena cava (SVC) were measured and analyzed for objective assessment. Two radiologists assessed the image quality and diagnostic confidence using a 5-point Likert scale. The CM doses were 46.81 ± 6.41mL, 41.96 ± 7.51mL and 34.65 ± 5.38mL for Group A, B and C, respectively. The objective assessments on AA, DA and the three main coronary arteries and the overall subjective scoring showed no significant difference among the three groups (all p > 0.05). The subjective assessment proved that excellent CCTA images can be obtained from the three different contrast media protocols. There were no significant differences in intracoronary attenuation values between the higher HR subgroup and the lower HR subgroup among three groups. CCTA reconstructed with DLIR could be realized with adequate enhancement in coronary arteries, excellent image quality and diagnostic confidence at low contrast dose of a 0.5mL/kg. The use of lower tube voltages may further reduce the contrast dose requirement.
- 9 May 2024
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 40 (6) , 1-12
Evaluation of image quality on low contrast media with deep learning image reconstruction algorithm in prospective ECG-triggering coronary CT angiography
To assess the impact of low-dose contrast media (CM) injection protocol with deep learning image reconstruction (DLIR) algorithm on image quality in coronary CT angiography (CCTA). In this prospective study, patients underwent CCTA were prospectively and randomly assigned to three groups with different contrast volume protocols (at 320mgI/mL concentration and constant flow rate of 5ml/s). After pairing basic information, 210 patients were enrolled in this study: Group A, 0.7mL/kg (n = 70); Group B, 0.6mL/kg (n = 70); Group C, 0.5mL/kg (n = 70). All patients were examined via a prospective ECG-triggered scan protocol within one heartbeat. A high level DLIR (DLIR-H) algorithm was used for image reconstruction with a thickness and interval of 0.625mm. The CT values of ascending aorta (AA), descending aorta (DA), three main coronary arteries, pulmonary artery (PA), and superior vena cava (SVC) were measured and analyzed for objective assessment. Two radiologists assessed the image quality and diagnostic confidence using a 5-point Likert scale. The CM doses were 46.81 ± 6.41mL, 41.96 ± 7.51mL and 34.65 ± 5.38mL for Group A, B and C, respectively. The objective assessments on AA, DA and the three main coronary arteries and the overall subjective scoring showed no significant difference among the three groups (all p > 0.05). The subjective assessment proved that excellent CCTA images can be obtained from the three different contrast media protocols. There were no significant differences in intracoronary attenuation values between the higher HR subgroup and the lower HR subgroup among three groups. CCTA reconstructed with DLIR could be realized with adequate enhancement in coronary arteries, excellent image quality and diagnostic confidence at low contrast dose of a 0.5mL/kg. The use of lower tube voltages may further reduce the contrast dose requirement.