Size Selective Dustiness and Exposure; Simulated Workplace Comparisons
Authors:
Open Access
- 8 March 2006
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 50 (5) , 445-452
Abstract
A simulated workplace study was conducted to investigate the relation between inhalation exposure and dustiness determined with a rotating drum dustiness tester. Three powders were used in the study, i.e. magnesium stearate, representing a very dusty powder, and aluminium oxide and calcium carbonate, representing low and very low dusty powders, respectively. Two scenarios of handling small volume of powders were included; sweeping/cleaning and scooping/weighing/adding. Size-selective dust exposure was assessed using MultiDust (dual-fraction) IOM and RespiCon® sampling heads. For the present operation scenarios, dustiness showed itself to be the major determinant of exposure and explained ∼70% of the exposure variances. The ratios of respirable and inhalable fractions as determined by dustiness tests were comparable with the ratios observed for exposure. The results emphasize the relevance of dustiness as a parameter to characterize substances according to potential for exposure.Keywords
This publication has 7 references indexed in Scilit:
- Exposure to Sulfuric Acid in Zinc ProductionAnnals of Occupational Hygiene, 2004
- Evaluation of the Respicon ® as a personal inhalable sampler in industrial environmentsJournal of Environmental Monitoring, 2002
- Applications of low-cost, dual-fraction dust samplersAnnals of Occupational Hygiene, 2001
- Development of a novel calibration tool for workplace aerosol samplers - review of progress of EU projectJournal of Aerosol Science, 2000
- DOCUMENTATION OF A DUSTINESS DRUM TESTAnnals of Occupational Hygiene, 1996
- DUSTINESS TESTING AND MOVING TOWARDS A BIOLOGICALLY RELEVANT DUSTINESS INDEXAnnals of Occupational Hygiene, 1994
- Correlation of Tests for Material Dustiness with Worker Exposure from the Bagging of PowdersApplied Industrial Hygiene, 1989