Evaluation of change in the contact of IOL with the posterior capsule with respect to the orientation of haptics of the IOL using intraoperative spectral domain optical coherence tomography
Authors:
Open Access
- 27 December 2024
- journal article
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (3) , 396-400
Abstract
Purpose: To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic–optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT). Methods: Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of IOL, with the haptics oriented horizontally and then vertically. Results: The vertical height between the posterior surface of the lens capsule and the posterior surface of IOL reduced significantly when the haptics were oriented vertically compared to horizontal orientation. This difference was found on analyzing both vertical as well as horizontal axis scans. Conclusion: We found a greater contact between the posterior capsule and the posterior surface of IOL, with the haptic optic junction of the IOL oriented vertically. This study also suggests the need for newer toric IOL designs which allow vertical orientation of haptics, leading to better contact between IOL and the bag.Keywords
This publication has 23 references indexed in Scilit:
- Pseudophakic DysphotopsiaOphthalmology, 2021
- New preventative approach for negative dysphotopsiaJournal of Cataract & Refractive Surgery, 2016
- Evaluation of intraocular lens position during phacoemulsification using intraoperative spectral-domain optical coherence tomographyJournal of Cataract & Refractive Surgery, 2016
- Impact of intraocular lens haptic design and orientation on decentration and tiltJournal of Cataract & Refractive Surgery, 2011
- Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantationJournal of Cataract & Refractive Surgery, 2003
- The capsular tension ring: Designs, applications, and techniquesJournal of Cataract & Refractive Surgery, 2000
- New classification of capsular block syndromeJournal of Cataract & Refractive Surgery, 1998
- A systematic overview of the incidence of posterior capsule opacificationOphthalmology, 1998
- Adhesiveness of AcrySof to a collagen filmJournal of Cataract & Refractive Surgery, 1998
- Sandwich theory: Bioactivity-based explanation for posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1997