Naren Shetty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Naren Shetty has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Apurva Bansod
Department and Institution, Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India
3 shared publicationsAkash Jain
Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India
2 shared publicationsRaghav Narasimhan
Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India
2 shared publicationsReshma Ranade
Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India
2 shared publicationsRudy Nuijts
University Eye Clinic Maastricht, Maastricht University Medical Center, Maastricht, the Netherlands
2 shared publicationsYash Patel
Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India
2 shared publications
Latest Publications
- Open Access
- 28 April 2025
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 5 (2) , 387
Steroid implant: A foreign body no more – mastering anterior chamber intrusion
Intraocular foreign bodies are common post-trauma. Rarely, an implant can migrate and lead to unintended complications. In this video, we describe a patient who presented with dislocation of an intraocular lens (IOL) implanted a few years ago. He underwent vitrectomy along with IOL explantation and was implanted with an iris claw IOL. Subsequently, the patient developed cystoid macular edema for which he was injected with a dexamethasone implant. Unfortunately, the implant migrated and was found in the anterior chamber. [1] Due to a delay in reviewing back, there was corneal endothelial decompensation, and the implant had to be extracted. [2-4] This video demonstrates the technique of removing the implant with the least possible manipulation to give an optimal outcome. Video Link: https://youtu.be/mG-Wjt3g_Kc
- 28 April 2025
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 5 (2) , 387
Open AccessSteroid implant: A foreign body no more – mastering anterior chamber intrusion
Intraocular foreign bodies are common post-trauma. Rarely, an implant can migrate and lead to unintended complications. In this video, we describe a patient who presented with dislocation of an intraocular lens (IOL) implanted a few years ago. He underwent vitrectomy along with IOL explantation and was implanted with an iris claw IOL. Subsequently, the patient developed cystoid macular edema for which he was injected with a dexamethasone implant. Unfortunately, the implant migrated and was found in the anterior chamber. [1] Due to a delay in reviewing back, there was corneal endothelial decompensation, and the implant had to be extracted. [2-4] This video demonstrates the technique of removing the implant with the least possible manipulation to give an optimal outcome. Video Link: https://youtu.be/mG-Wjt3g_Kc
- Open Access
- 26 February 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (3) , 341-345
Evaluation of change in the orientation of intraocular lens in the bag using intraoperative spectral-domain optical coherence tomography before and after capsular tension ring implantation
Purpose: The purpose is to study the change in the contact of the IOL with the posterior capsule using intraoperative SD-OCT before and after implantation of the CTR post implantation of the IOL in the capsular bag. Methods: A total of 51 eyes of 51 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of an extended depth of focus intraocular lens by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of the IOL and before and after implantation of appropriate size of CTR. The vertical height between posterior surface of the lens capsule and the posterior surface of the IOL was measured and compared across 3 CTR sizes. Results: The vertical height between the posterior surface of the lens capsule and the posterior surface of the IOL reduced significantly post CTR implantation ( P value < 0.001) in all three groups. The change in height after CTR implantation was seen highest with the CTR size 13 mm and lowest with CTR size 11 mm. Conclusion: Significant improvement of contact between the IOL and the posterior capsule was shown after implantation of the CTR. Larger the size CTR, more the contact of the IOL with the bag was shown.
- 26 February 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (3) , 341-345
Open AccessEvaluation of change in the orientation of intraocular lens in the bag using intraoperative spectral-domain optical coherence tomography before and after capsular tension ring implantation
Purpose: The purpose is to study the change in the contact of the IOL with the posterior capsule using intraoperative SD-OCT before and after implantation of the CTR post implantation of the IOL in the capsular bag. Methods: A total of 51 eyes of 51 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of an extended depth of focus intraocular lens by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of the IOL and before and after implantation of appropriate size of CTR. The vertical height between posterior surface of the lens capsule and the posterior surface of the IOL was measured and compared across 3 CTR sizes. Results: The vertical height between the posterior surface of the lens capsule and the posterior surface of the IOL reduced significantly post CTR implantation ( P value < 0.001) in all three groups. The change in height after CTR implantation was seen highest with the CTR size 13 mm and lowest with CTR size 11 mm. Conclusion: Significant improvement of contact between the IOL and the posterior capsule was shown after implantation of the CTR. Larger the size CTR, more the contact of the IOL with the bag was shown.
- Open Access
- 30 January 2025
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 5 (1) , 172-173
Anterior polar cataract with capsular fibrosis and dehiscence
- 30 January 2025
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 5 (1) , 172-173
Open AccessAnterior polar cataract with capsular fibrosis and dehiscence
- Open Access
- 30 January 2025
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 5 (1) , 189-191
Capsular contraction and bag distension syndrome in retinitis pigmentosa
- 30 January 2025
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 5 (1) , 189-191
Open AccessCapsular contraction and bag distension syndrome in retinitis pigmentosa
- Open Access
- 27 December 2024
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (3) , 396-400
Evaluation of change in the contact of IOL with the posterior capsule with respect to the orientation of haptics of the IOL using intraoperative spectral domain optical coherence tomography
Purpose: To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic–optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT). Methods: Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of IOL, with the haptics oriented horizontally and then vertically. Results: The vertical height between the posterior surface of the lens capsule and the posterior surface of IOL reduced significantly when the haptics were oriented vertically compared to horizontal orientation. This difference was found on analyzing both vertical as well as horizontal axis scans. Conclusion: We found a greater contact between the posterior capsule and the posterior surface of IOL, with the haptic optic junction of the IOL oriented vertically. This study also suggests the need for newer toric IOL designs which allow vertical orientation of haptics, leading to better contact between IOL and the bag.
- 27 December 2024
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (3) , 396-400
Open AccessEvaluation of change in the contact of IOL with the posterior capsule with respect to the orientation of haptics of the IOL using intraoperative spectral domain optical coherence tomography
Purpose: To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic–optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT). Methods: Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of IOL, with the haptics oriented horizontally and then vertically. Results: The vertical height between the posterior surface of the lens capsule and the posterior surface of IOL reduced significantly when the haptics were oriented vertically compared to horizontal orientation. This difference was found on analyzing both vertical as well as horizontal axis scans. Conclusion: We found a greater contact between the posterior capsule and the posterior surface of IOL, with the haptic optic junction of the IOL oriented vertically. This study also suggests the need for newer toric IOL designs which allow vertical orientation of haptics, leading to better contact between IOL and the bag.
- Open Access
- 1 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (12) , 1208-1214
Effect of digital cataract workflow on time and resource efficiencies in cataract surgery: time and motion study
Purpose: To compare time and resource saving with integration of digital cataract workflow to the existing workflow in high-volume cataract surgery clinics. Setting: L V Prasad Eye Institute, Hyderabad, India (site 1), and Narayana Nethralaya, Bengaluru, India (site 2). Design: Prospective, time and motion. Methods: The total time to complete each step (preoperative measurements, surgical planning, and surgical procedures) of the cataract workflow, number of data fields entered, and support staff required for both workflows were recorded. All study measurements were determined first for existing electronic medical record (EMR) cataract workflow followed by digital workflow (integrated data management system with data reviewer, surgical planner, and data transfer to operating room) at both sites. Results: A total of 85 (site 1, 44; site 2, 41) cataract workflows were analyzed. The integration of digital workflow into the site's existing EMR workflow reduced the mean time for preoperative measurements by 25.3% (P = .006), surgical planning by 55.1% (P = .008), and surgical procedures by 22.6% (P = .002). The mean ± SD overall time for the surgery was significantly shorter in the digital group (887.3 ± 103.3 vs 1271.3 ± 300.7 seconds; P < .0001). For both sites, the number of data fields recorded and number of support staff needed were significantly lesser for the digital workflow (P < .0001, for both). Conclusions: Integration of digital workflow significantly reduced the overall cataract surgery time, variability of overall time, number of data fields recorded, and resource utilization. Complete digitalization has important implications for improving the efficiency and standardization of cataract surgery workflow.
- 1 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (12) , 1208-1214
Open AccessEffect of digital cataract workflow on time and resource efficiencies in cataract surgery: time and motion study
Purpose: To compare time and resource saving with integration of digital cataract workflow to the existing workflow in high-volume cataract surgery clinics. Setting: L V Prasad Eye Institute, Hyderabad, India (site 1), and Narayana Nethralaya, Bengaluru, India (site 2). Design: Prospective, time and motion. Methods: The total time to complete each step (preoperative measurements, surgical planning, and surgical procedures) of the cataract workflow, number of data fields entered, and support staff required for both workflows were recorded. All study measurements were determined first for existing electronic medical record (EMR) cataract workflow followed by digital workflow (integrated data management system with data reviewer, surgical planner, and data transfer to operating room) at both sites. Results: A total of 85 (site 1, 44; site 2, 41) cataract workflows were analyzed. The integration of digital workflow into the site's existing EMR workflow reduced the mean time for preoperative measurements by 25.3% (P = .006), surgical planning by 55.1% (P = .008), and surgical procedures by 22.6% (P = .002). The mean ± SD overall time for the surgery was significantly shorter in the digital group (887.3 ± 103.3 vs 1271.3 ± 300.7 seconds; P < .0001). For both sites, the number of data fields recorded and number of support staff needed were significantly lesser for the digital workflow (P < .0001, for both). Conclusions: Integration of digital workflow significantly reduced the overall cataract surgery time, variability of overall time, number of data fields recorded, and resource utilization. Complete digitalization has important implications for improving the efficiency and standardization of cataract surgery workflow.
- Open Access
- 29 July 2014
- Published by Springer Nature in Journal of Ophthalmic Inflammation and Infection
- Vol. 4 (1) , 1-10
Combined depth imaging of choroid in uveitis
- 29 July 2014
- Published by Springer Nature in Journal of Ophthalmic Inflammation and Infection
- Vol. 4 (1) , 1-10
Open AccessCombined depth imaging of choroid in uveitis