One of the biggest challenges for neurotechnology is the design of devices that are tolerated well by brain tissue, without sacrificing functionality and implantability. This study examined which design choices mitigate tissue damage and improve longevity, by varying probe features implanted in the cerebral cortex of mice. We report on a systematic, quantitative analysis of neuronal and inflammation markers across cortical depth. We implanted a total of 103 stiff silicon or flexible polyimide probes in 32 mice, varying their thicknesses and widths, which were either attached to the skull or not. A new, automated workflow to quantify immunohistochemical data examines: 1) the tissue loss caused by the implant, 2) the cortical neuronal density, and 3) the immune response expressed by astrocytic and microglial reaction. Flexible polyimide probes exhibited a clear advantage, with fewer lesions and weaker immune responses than stiff silicon probes. Furthermore, we observed a weaker influence of the shank cross-section. A cortical depth profile of immune reactivity revealed focal reactions at the device entry points in the superficial cortex and at the cortex-white matter boundary. This study gives important insights on optimizing device design parameters as well as surgical insights for improved tissue integration of intracortical electrode arrays.Keywords
All Related Versions
- Published version: Advanced Science, e00028.
Funding Information
- European Union Horizon 2020 Framework Program (899287)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (17619)
- LSH Match Project (LSHM23002)
- NIH Research Project (R01EY036094)
- HORIZON EUROPE Framework Programme (101147319)
This publication has 62 references indexed in Scilit:
- Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegenerationJournal of Neural Engineering, 2009
- Neural probe design for reduced tissue encapsulation in CNSBiomaterials, 2007
- Thin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortexJournal of Neural Engineering, 2007
- Response of brain tissue to chronically implanted neural electrodesJournal of Neuroscience Methods, 2005
- Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arraysExperimental Neurology, 2005
- Chronic multiunit recordings in behaving animals: advantages and limitations2005
- Chronic response of adult rat brain tissue to implants anchored to the skullBiomaterials, 2004
- Large-scale recording of neuronal ensemblesNature Neuroscience, 2004
- Brain responses to micro-machined silicon devicesBrain Research, 2003
- A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode arrayIEEE Transactions on Biomedical Engineering, 1991