Rik J. J. van Daal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rik J. J. van Daal has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Arno Aarts
ATLAS Neuroengineering BV Leuven Belgium
3 shared publications - Fabian Kloosterman
VIB-KU Leuven Center for Neuroscience/NERF, Leuven, Belgium
3 shared publications - Cagatay Aydin
Neuroelectronics Research Flanders, Leuven, Belgium
2 shared publications - Christian Boehler
Intelligent Machine‐Brain Interfacing Technology (IMBIT) University of Freiburg Freiburg Germany
2 shared publications - Corinne Orlemann
Department of Vision and Cognition Netherlands Institute for Neuroscience Amsterdam Netherlands
2 shared publications - Frédéric Michon
Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA Amsterdam, Netherlands
2 shared publications
Latest Publications
- Open Access
- 15 April 2026
- Published by Wiley in Advanced Science
- p. e00028
Friend, Not Foe: Lowered Tissue Reactivity to Long‐Term Polyimide Implants
One of the biggest challenges for neurotechnology is the design of devices that are tolerated well by brain tissue, without sacrificing functionality and implantability. This study examined which design choices mitigate tissue damage and improve longevity by varying probe features implanted in the cerebral cortex of mice. We report on a systematic, quantitative analysis of neuronal and inflammation markers across cortical depth. We implanted a total of 103 stiff silicon or flexible polyimide probes in 32 mice, varying their thicknesses and widths, and either attaching them to the skull or not. A new, automated workflow to quantify immunohistochemical data examines: 1) the tissue loss caused by the implant, 2) the cortical neuronal density, and 3) the immune response expressed by astrocytic and microglial reaction. Flexible polyimide probes exhibited a clear advantage, causing fewer lesions and weaker immune responses than stiff silicon probes. Furthermore, we observed a weak influence of the shank cross‐section. A cortical depth profile of immune reactivity revealed focal reactions at the device entry points in the superficial cortex and at the cortex‐white matter boundary. This study gives important insights on optimizing device design parameters as well as surgical insights for improved tissue integration of intracortical electrode arrays.
- 15 April 2026
- Published by Wiley in Advanced Science
- p. e00028
Open AccessFriend, Not Foe: Lowered Tissue Reactivity to Long‐Term Polyimide Implants
One of the biggest challenges for neurotechnology is the design of devices that are tolerated well by brain tissue, without sacrificing functionality and implantability. This study examined which design choices mitigate tissue damage and improve longevity by varying probe features implanted in the cerebral cortex of mice. We report on a systematic, quantitative analysis of neuronal and inflammation markers across cortical depth. We implanted a total of 103 stiff silicon or flexible polyimide probes in 32 mice, varying their thicknesses and widths, and either attaching them to the skull or not. A new, automated workflow to quantify immunohistochemical data examines: 1) the tissue loss caused by the implant, 2) the cortical neuronal density, and 3) the immune response expressed by astrocytic and microglial reaction. Flexible polyimide probes exhibited a clear advantage, causing fewer lesions and weaker immune responses than stiff silicon probes. Furthermore, we observed a weak influence of the shank cross‐section. A cortical depth profile of immune reactivity revealed focal reactions at the device entry points in the superficial cortex and at the cortex‐white matter boundary. This study gives important insights on optimizing device design parameters as well as surgical insights for improved tissue integration of intracortical electrode arrays.
- Open Access
Friend, not Foe: Lowered Tissue Reactivity to Long-Term Polyimide Implants
One of the biggest challenges for neurotechnology is the design of devices that are tolerated well by brain tissue, without sacrificing functionality and implantability. This study examined which design choices mitigate tissue damage and improve longevity, by varying probe features implanted in the cerebral cortex of mice. We report on a systematic, quantitative analysis of neuronal and inflammation markers across cortical depth. We implanted a total of 103 stiff silicon or flexible polyimide probes in 32 mice, varying their thicknesses and widths, which were either attached to the skull or not. A new, automated workflow to quantify immunohistochemical data examines: 1) the tissue loss caused by the implant, 2) the cortical neuronal density, and 3) the immune response expressed by astrocytic and microglial reaction. Flexible polyimide probes exhibited a clear advantage, with fewer lesions and weaker immune responses than stiff silicon probes. Furthermore, we observed a weaker influence of the shank cross-section. A cortical depth profile of immune reactivity revealed focal reactions at the device entry points in the superficial cortex and at the cortex-white matter boundary. This study gives important insights on optimizing device design parameters as well as surgical insights for improved tissue integration of intracortical electrode arrays.
Open AccessFriend, not Foe: Lowered Tissue Reactivity to Long-Term Polyimide Implants
One of the biggest challenges for neurotechnology is the design of devices that are tolerated well by brain tissue, without sacrificing functionality and implantability. This study examined which design choices mitigate tissue damage and improve longevity, by varying probe features implanted in the cerebral cortex of mice. We report on a systematic, quantitative analysis of neuronal and inflammation markers across cortical depth. We implanted a total of 103 stiff silicon or flexible polyimide probes in 32 mice, varying their thicknesses and widths, which were either attached to the skull or not. A new, automated workflow to quantify immunohistochemical data examines: 1) the tissue loss caused by the implant, 2) the cortical neuronal density, and 3) the immune response expressed by astrocytic and microglial reaction. Flexible polyimide probes exhibited a clear advantage, with fewer lesions and weaker immune responses than stiff silicon probes. Furthermore, we observed a weaker influence of the shank cross-section. A cortical depth profile of immune reactivity revealed focal reactions at the device entry points in the superficial cortex and at the cortex-white matter boundary. This study gives important insights on optimizing device design parameters as well as surgical insights for improved tissue integration of intracortical electrode arrays.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 6, 333-339
Low-Frequency Biplane Imaging With Row–Column PMUT on a Conventional Silicon Wafer
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 6, 333-339
Open AccessLow-Frequency Biplane Imaging With Row–Column PMUT on a Conventional Silicon Wafer
- 9 June 2021
- Published by Springer Nature in Nature Protocols
- Vol. 16 (7) , 3322-3347
Implantation of Neuropixels probes for chronic recording of neuronal activity in freely behaving mice and rats
How dynamic activity in neural circuits gives rise to behavior is a major area of interest in neuroscience. A key experimental approach for addressing this question involves measuring extracellular neuronal activity in awake, behaving animals. Recently developed Neuropixels probes have provided a step change in recording neural activity in large tissue volumes with high spatiotemporal resolution. This protocol describes the chronic implantation of Neuropixels probes in mice and rats using compact and reusable 3D-printed fixtures. The fixtures facilitate stable chronic in vivo recordings in freely behaving rats and mice. They consist of two parts: a covered main body and a skull connector. Single-, dual- and movable-probe fixture variants are available. After completing an experiment, probes are safely recovered for reimplantation by a dedicated retrieval mechanism. Fixture assembly and surgical implantation typically take 4–5 h, and probe retrieval takes ~30 min, followed by 12 h of incubation in probe cleaning agent. The duration of data acquisition depends on the type of behavioral experiment. Since our protocol enables stable, chronic recordings over weeks, it enables longitudinal large-scale single-unit data to be routinely obtained in a cost-efficient manner, which will facilitate many studies in systems neuroscience.
- 9 June 2021
- Published by Springer Nature in Nature Protocols
- Vol. 16 (7) , 3322-3347
Implantation of Neuropixels probes for chronic recording of neuronal activity in freely behaving mice and rats
How dynamic activity in neural circuits gives rise to behavior is a major area of interest in neuroscience. A key experimental approach for addressing this question involves measuring extracellular neuronal activity in awake, behaving animals. Recently developed Neuropixels probes have provided a step change in recording neural activity in large tissue volumes with high spatiotemporal resolution. This protocol describes the chronic implantation of Neuropixels probes in mice and rats using compact and reusable 3D-printed fixtures. The fixtures facilitate stable chronic in vivo recordings in freely behaving rats and mice. They consist of two parts: a covered main body and a skull connector. Single-, dual- and movable-probe fixture variants are available. After completing an experiment, probes are safely recovered for reimplantation by a dedicated retrieval mechanism. Fixture assembly and surgical implantation typically take 4–5 h, and probe retrieval takes ~30 min, followed by 12 h of incubation in probe cleaning agent. The duration of data acquisition depends on the type of behavioral experiment. Since our protocol enables stable, chronic recordings over weeks, it enables longitudinal large-scale single-unit data to be routinely obtained in a cost-efficient manner, which will facilitate many studies in systems neuroscience.
- Top Cited Papers
- 16 April 2021
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 372 (6539) , 258-+
Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings
Recording many neurons for a long time: The ultimate aim of chronic recordings is to sample from the same neuron over days and weeks. However, this goal has been difficult to achieve for large populations of neurons. Steinmetz et al. describe the development and testing of Neuropixels 2.0. This new electrophysiological recording tool is a miniaturized, high-density probe for both acute and long-term experiments combined with sophisticated software algorithms for fully automatic post hoc computational stabilization. The technique also provides a strategy for extending the number of recorded sites beyond the number of available recording channels. In freely moving animals, extremely large numbers of individual neurons could thus be followed and tracked with the same probe for weeks and occasionally months. Science , this issue p. eabf4588
- 16 April 2021
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 372 (6539) , 258-+
Top Cited PapersNeuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings
Recording many neurons for a long time: The ultimate aim of chronic recordings is to sample from the same neuron over days and weeks. However, this goal has been difficult to achieve for large populations of neurons. Steinmetz et al. describe the development and testing of Neuropixels 2.0. This new electrophysiological recording tool is a miniaturized, high-density probe for both acute and long-term experiments combined with sophisticated software algorithms for fully automatic post hoc computational stabilization. The technique also provides a strategy for extending the number of recorded sites beyond the number of available recording channels. In freely moving animals, extremely large numbers of individual neurons could thus be followed and tracked with the same probe for weeks and occasionally months. Science , this issue p. eabf4588
- 1 February 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (1) , 016046
System for recording from multiple flexible polyimide neural probes in freely behaving animals
Objective . Long-term electrophysiological recordings of neural activity in freely behaving animals are indispensable to advance the understanding of complex brain function. It is a technical challenge to chronically monitor the detailed activity across multiple distributed brain regions in freely behaving animals over a period of months. Here we present a new implant for inserting multiple flexible polyimide probes into freely behaving rats for monitoring the brain activity over a long time period. Approach . This brain implant integrates multiple flexible probes in small micromanipulator devices that ensure free behaviour of the animal. The probes are micromachined and the positioning mechanism is 3D-printed using stereolithography. Each probe is lowered by a screw-driven shuttle and guided through an exit tip before penetrating the rat’s brain. Main results . The brain implant consists of 16 individually lowerable flexible polyimide probes that contain 16 embedded electrodes adding up to a total of 256 recording channels. The total travel distance is 8 mm. The assembly time of the device was only one day. The electrode impedance values had a mean of 335 kΩ and sample standard deviation of 107 kΩ after gold plating, excluding outliers. Significance . For the first time, hyperdrive-assisted insertion of flexible multichannel probes was demonstrated. Local field potentials and neuronal spiking activity from freely behaving rats were recorded over months.
- 1 February 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (1) , 016046
System for recording from multiple flexible polyimide neural probes in freely behaving animals
Objective . Long-term electrophysiological recordings of neural activity in freely behaving animals are indispensable to advance the understanding of complex brain function. It is a technical challenge to chronically monitor the detailed activity across multiple distributed brain regions in freely behaving animals over a period of months. Here we present a new implant for inserting multiple flexible polyimide probes into freely behaving rats for monitoring the brain activity over a long time period. Approach . This brain implant integrates multiple flexible probes in small micromanipulator devices that ensure free behaviour of the animal. The probes are micromachined and the positioning mechanism is 3D-printed using stereolithography. Each probe is lowered by a screw-driven shuttle and guided through an exit tip before penetrating the rat’s brain. Main results . The brain implant consists of 16 individually lowerable flexible polyimide probes that contain 16 embedded electrodes adding up to a total of 256 recording channels. The total travel distance is 8 mm. The assembly time of the device was only one day. The electrode impedance values had a mean of 335 kΩ and sample standard deviation of 107 kΩ after gold plating, excluding outliers. Significance . For the first time, hyperdrive-assisted insertion of flexible multichannel probes was demonstrated. Local field potentials and neuronal spiking activity from freely behaving rats were recorded over months.