Similar survival between screw cementless and cemented tibial components in young patients with osteoarthritis
- 8 November 2012
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 22 (7) , 1585-1590
Abstract
Purpose: The aim of this study was to compare the outcomes of tibial fixation with either a cemented or cementless with screw augmentation component in young patients with non‐inflammatory arthritis.Methods: Ninety‐three patients aged 55 or younger with non‐inflammatory arthritis were randomized to compare outcomes between cemented tibial fixation (48 patients) and cementless fixation with screw augmentation (45 patients). The femoral component was cementless in both groups. Post‐operative evaluation was assessed by the clinical and radiological criteria of The Knee Society and WOMAC questionnaire.Results: The median follow‐up was 6.7 (5–12) years. Significant differences were found for knee score (p = 0.02), range of motion (p = 0.04), and WOMAC score (p = 0.03). In the cemented group, there was one deep wound infection, four tibial aseptic loosening, and one polyethylene wear, all of which were revised. In the cementless group there was one tibial aseptic loosening and one polyethylene wear, both being revised. There was no difference in revision rate, and the cumulative survival at 9‐year for aseptic reason was 93.7 % (95 % CI, 82–100 %) in the cementless group and 90.0 % (95 % CI, 80–100 %) in the cemented group (n.s.).Conclusions: Cementless total knee arthroplasty was found to be a reliable option in younger patients with osteoarthritis. Although the revision rate and survival were similar in both groups, better clinical outcomes were obtained with cementless tibial components.Level of evidence: I.Keywords
This publication has 23 references indexed in Scilit:
- Hydroxyapatite (HA) coating appears to be of benefit for implant durability of tibial components in primary total knee arthroplastyActa Orthopaedica, 2011
- Wear and Lysis is the Problem in Modular TKA in the Young OA Patient at 10 YearsClinical Orthopaedics and Related Research, 2011
- Survival and clinical function of cemented and uncemented prostheses in total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2009
- Cemented versus uncemented fixation of the femoral component of the NexGen CR total knee replacement in patients younger than 60 yearsThe Knee, 2009
- Cemented Total Knee Arthroplasty Using a Modern Prosthesis in Young Patients With OsteoarthritisThe Journal of Arthroplasty, 2007
- Five- to 12-year follow-up of a hydroxyapatite-coated, cementless total knee replacement in young, active patientsThe Journal of Bone and Joint Surgery. British volume, 2006
- Uncemented HA-coated Implant is the Optimum Fixation for TKA in the Young PatientClinical Orthopaedics and Related Research, 2006
- Total knee arthroplasty in patients ≤50 years oldThe Journal of Arthroplasty, 2002
- A randomised, controlled trial of cemented versus cementless press-fit condylar total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2002
- The Swedish Knee Arthroplasty Register 1975-1997: An update with special emphasis on 41,223 knees operated on in 1988-1997Acta Orthopaedica, 2001