Nuclear interaction correction based on dual-energy computed tomography in carbon-ion radiotherapy
- 21 February 2025
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (5) , 055012
Abstract
Objective. Accurate dose predictions are crucial to maximizing the benefits of carbon-ion therapy (CIT). Carbon beams incident on the human body cause nuclear interactions with tissues, resulting in changes in the constituent nuclides and leading to dose errors that are conventionally corrected using conventional single-energy computed tomography (SECT). Dual-energy computed tomography (DECT) has frequently been used for stopping power estimation in particle therapy and is well suited for correcting nuclear reactions because of its detailed body-tissue elemental information. This study proposes a correction method for the absolute dose in CIT that considers changes in nuclide composition resulting from nuclear reactions with body tissues, as a novel application of DECT. Approach. The change in dose associated with nuclear reactions is determined by correcting each integrated depth dose component of the carbon beam using a nuclear interaction correction factor. This factor is determined based on the stopping power, mass density, and nuclear interaction cross-section in body tissue. The stopping power and mass density were calculated using established methods, whereas the nuclear interaction cross-section was newly defined through a conversion equation derived from the effective atomic number. Main results. Nuclear interaction correction factors and corrected doses were determined for 85 body tissues with known compositions, comparing them with existing SECT-based methods. The root-mean-square errors of the SECT- and DECT-based nuclear interaction correction factors relative to theoretical values were 0.66% and 0.39%, respectively. Significance. This indicates a notable enhancement in the estimation accuracy with DECT. The dose calculations in uniform body tissues derived from SECT showed slight over-correction in adipose and bone tissues, whereas those based on DECT were almost consistent with theoretical values. Our proposed method demonstrates the potential of DECT for enhancing dose calculation accuracy in CIT, complementing its established role in stopping power estimation.Keywords
Funding Information
- Japan Society for the Promotion of Science (17K16437)
This publication has 40 references indexed in Scilit:
- Commissioning and Validation of CT Number to SPR Calibration in Carbon Ion Therapy FacilityInternational Journal of Particle Therapy, 2024
- Dose calculation accuracy in particle therapy: Comparing carbon ions with protonsMedical Physics, 2021
- Physical and biological beam modeling for carbon beam scanning at Osaka Heavy Ion Therapy CenterJournal of Applied Clinical Medical Physics, 2021
- Quadratic relation for mass density calibration in human body using dual‐energy CT dataMedical Physics, 2021
- Estimation of electron density, effective atomic number and stopping power ratio using dual-layer computed tomography for radiotherapy treatment planningPhysica Medica, 2018
- Inter-centre variability of CT-based stopping-power prediction in particle therapy: Survey-based evaluationPhysics and Imaging in Radiation Oncology, 2018
- Simplified derivation of stopping power ratio in the human body from dual‐energy CT dataMedical Physics, 2017
- A simple formulation for deriving effective atomic numbers via electron density calibration from dual-energy CT data in the human bodyMedical Physics, 2017
- Realistic reference phantoms: An ICRP/ICRU joint effortAnnals of the ICRP, 2009
- Evaluation of the collision stopping power of elements and compounds for electrons and positronsThe International Journal of Applied Radiation and Isotopes, 1982