MYMasashi Yagi

Masashi Yagi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Masashi Yagi has a total of 109 co-authors. Here are the top co-authors by number of shared publications:

  • Tatsuaki Kanai

    Medical Physics Laboratory, Division of Health Science, Graduate School of Medicine, The University of Osaka, Osaka, Japan

    11 shared publications
  • Noriaki Hamatani

    Department of Medical Physics, Osaka Heavy-Ion Therapy Center, Osaka, Japan

    9 shared publications
  • Kazuhiko Ogawa

    Graduate School of Medicine, Osaka University, 2-2 Yamada-oka, Suita, Osaka, 565-0871, JAPAN

    8 shared publications
  • Toshiro Tsubouchi

    Department of Medical Physics, Osaka Heavy-Ion Therapy Center, Osaka, Japan

    8 shared publications
  • Shinichi Shimizu

    The University of Osaka Graduate School of Medicine

    7 shared publications
  • Masaaki Takashina

    Department of Medical Physics, Osaka Heavy-Ion Therapy Center, Osaka, Japan

    6 shared publications

Latest Publications

  • A generalized phenomenological model of oxygen depletion for FLASH particle radiotherapy: evidence from in vitro data

    by Kailin Fu, Jun Ken Gan, Masashi Yagi, Clifford Ghee Ann Chua, Kang Hao Lee, Kah Seng Lew, Calvin Wei Yang Koh, Kazumasa Minami, Yeap Ping Lin, Andrew Wibawa, et al.

    Objective. Ultra-high dose rate (uHDR: FLASH) radiotherapy reduces normal tissue toxicity while preserving tumor control. The oxygen depletion hypothesis posits that rapid oxygen consumption during FLASH irradiation transiently reduces radiosensitivity. However, experimental measurements suggest oxygen depletion may be limited, particularly under normoxia. This study quantitatively assesses the adequacy of this hypothesis in reproducing experimentally observed sparing effects by comparing mechanistic simulations with in vitro cell survival data across a wide range of irradiation conditions. Approach. We developed a phenomenological framework for radiolytic oxygen depletion incorporating temporal dose delivery, dose rate, and linear energy transfer (LET). LET dependence was included through oxygen consumption efficiency and the maximum oxygen enhancement ratio. For direct comparison, simulation results were linked to clonogenic cell survival using a damage reduction factor (DRF) derived from the linear-quadratic model. Simulated DRFs were compared with experimental DRFs from six independent in vitro studies involving electrons, protons, helium ions, and carbon ions over broad ranges of LET, oxygenation, and dose rates using parity plots, residual analyses, stratified weighted statistics, and correlation analyses. Main results. Under most irradiation conditions, simulated DRFs remained close to unity (minimum values approximately 0.96), indicating limited predicted protection from oxygen depletion. Conversely, experimental DRFs exhibited substantially larger deviations. Stratified analyses revealed systematic discrepancies between simulated and experimental DRFs across oxygenation, LET, and dose rate, with pronounced disagreement under normoxia, high LET, and uHDRs. Residual analyses demonstrated underestimation of the sparing effect by the model. Correlation analyses showed statistically insignificant associations between simulated and experimental metrics. Significance. The oxygen depletion model considered in this work insufficiently reproduces the observed sparing effect under the in vitro conditions considered. Additional biological and physicochemical mechanisms likely play a significant role. This framework provides a quantitative basis for evaluating alternative mechanisms and integrating future experimental data toward a more complete understanding of FLASH radiotherapy.

  • Impact of x-ray contamination in the dose monitor on beam abortion during uninterrupted continuous delivery in proton therapy

    by Masashi Yagi, Kah Seng Lew, Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kang Hao Lee, James Cheow Lei Lee, Sung Yong Park, Hong Qi Tan

    Objective: Real-time Gated Proton Therapy (RGPT) enables precise irradiation of moving targets and is an important motion-management technique in proton therapy. Uninterrupted continuous delivery (UCD), in which fluoroscopic X-rays remain on during proton irradiation, may improve beam stability and treatment efficiency, particularly in synchrotronbased systems using continuous beams. However, scattered fluoroscopic X-rays may be detected by the dose monitor (DM) and mistakenly counted as proton monitor units, potentially causing beam aborts. This study aimed to quantify scattered fluoroscopic X-rays detected by the DM during RGPT and evaluate their impact on beam delivery during simultaneous fluoroscopy and proton irradiation.Methods: Scattered fluoroscopic X-ray signals detected by the DM were measured using an RGPT system. Phantom experiments evaluated scattered X-ray dose rates while varying phantom thickness, fluoroscopic parameters, and range-shifter conditions. Beam-abort simulations were conducted under UCD conditions for both phantom and clinical liver cases.Abort probability was assessed as a function of proton MU per spot, scattered X-ray MU per frame, and fluoroscopy frame rate (FPS).Results: DM signals from scattered fluoroscopic X-rays increased with tube voltage, tube current, field size, and phantom thickness, and were higher without a range shifter. The maximum dose rate was 0.0211 MU/frame at 125 kV, 80 mAs, 200 × 200 mm², and PW-30 cm without a range shifter, representing an 11.7-fold increase compared with in-air conditions. Beam-abort simulations showed abort proportions below 2% for monoenergetic fields and below 3% for clinical liver plans across all tested conditions. Significance: With the DM positioned closer to the X-ray tube, scattered fluoroscopic X-ray contamination increased with phantom thickness, differing from prior reports. Optimization of proton dose rate, imaging parameters, and system geometry can minimize beam interruptions, supporting the clinical feasibility of UCD.

  • Parametric regression model approach for CT-based prediction of stopping power ratio for a Hounsfield look-up table

    by Masashi Yagi, Wei Yang Calvin Koh, Kah Seng Lew, Clifford Ghee Ann Chua, Ping Lin Yeap, Andrew Wibawa, Zubin Master, James Cheow Lei Lee, Sung Yong Park, Hong Qi Tan

    This study proposes a computed tomography (CT) number (CTN)-to-stopping power ratio (SPR) calibration method that can be directly combined with the established CTN-to-density conversion curves used in photon therapy. Furthermore, it evaluates the method’s robustness against tissue variations and assesses dose differences compared with current calibration methods for scanned proton therapy. To develop the CTN-to-SPR calibration curve, relative electron densities (REDs) derived from a CIRS Model 062 M electron density phantom with tissue-substitute inserts were applied to a parametric regression model (PRM) constructed from 53 standard human tissues (including both male and female reference data from ICRP Publication 110). PRM stability was tested by varying the mass density and elemental composition of the reference tissues and recalculating SPRs from RED and CTN. For dose evaluation, we analyzed six representative patients and an expanded cohort of 30 additional patients (10 each for the head-and-neck, chest, and pelvis) whose CT datasets were retrospectively acquired at 80 or 120 kV. For the calibration, phantom CT datasets were acquired using Siemens SOMATOM X.cite and GE Revolution CT ES scanners at 100 kV. Treatment plans were recalculated using the PRM-derived Hounsfield look-up table (HLUT; CTN‐to‐SPR PRM ) without re-optimization. The dose impact and consistency were then evaluated against the current clinical standard (CTN‐to‐SPR clin ) using dose–volume histograms (DVHs). RED-based SPR was expressed as SPR = − 0.0173 ρ e 3 + 0.0057 ρ e 2 + 1.0163 ρ e , (root-mean-square error (RMSE) ∼0.82% relative to the theoretical SPR for 53 ICRP reference tissues, 0.68% without air). The CTN‐to‐SPR PRM and CTN‐to‐SPR clin calibration curves showed consistent profiles; therefore, unified curves using averaged CTNs were applied due to the negligible differences between head and body phantom sizes. Compared to CTN‐to‐SPR clin , the proposed CTN‐to‐SPR PRM yielded higher SPR values in the lung and bone regions, but lower SPR values in the soft tissue regions. The relative differences between the two calibration curves were within 3% between −200 and +200 Hounsfield unit (HU). In the extreme density regions, the differences were >25% at −800 HU, and 1.23% and 0.11% at 1000 HU for the Siemens and GE scanners, respectively. Hydrogen and calcium variations caused the largest RMSE increases (1.58% and 6.00%), and trends were consistent across sexes. In the representative cases, DVH deviations were generally within 3%, except −5% in left parotid and −4.2% in lung Dmean. Across the expanded 30-case cohort, the PRM maintained robust target coverage and organs at risk sparing with minimal relative dose differences. Our findings suggest the potential of the CTN-to-SPR PRM approach for SPR estimation, providing a basis for discussing more flexible and streamlined CT calibration protocols.

  • Ion recombination correction in reference dosimetry for pencil beam scanned proton beams

    by Jun Ken Gan, Kah Seng Lew, Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kang Hao Lee, Masashi Yagi, Wen Siang Lew, James Cheow Lei Lee, Sung Yong Park, Hong Qi Tan

    Background: The 2024 IAEA TRS‐398 revision updated recommendations for reference dosimetry and ion recombination corrections in pencil beam scanned (PBS) proton beams. Purpose: This study evaluates the revised ion recombination methods for monoenergetic synchrotron‐based PBS proton system across different energies, monitor units (MU), and ionization chamber types. Methods: Reference‐field measurements were performed using a synchrotron system at 70.2, 150.2, and 228.7 MeV and at 6, 50, and 200 MU. Charge‐collection data were acquired using PTW Farmer and Advanced Markus chambers across 20–400 V. Ion recombination correction factors () were determined using the Jaffé plot extrapolation method and the TRS‐398 two‐voltage method (TVM) under different time structure assumptions. Charge multiplication in the chamber was addressed using both low voltage linear fitting and a semiempirical exponential model. Results: For low energy, low MU fields, and TVM yielded values within ∼1% of the Jaffé extrapolation. For high‐energy, high‐MU fields, maximum differences of 6.25% (Farmer) and 1.62% (Advanced Markus) were observed. The synchrotron beam exhibited energy, MU, and chamber dependent time structure behavior, producing pulsed‐like or continuous‐like characteristics. Misclassification of the time structure resulted in additional deviations of up to 2.49% (Farmer) and 0.59% (Advanced Markus). Charge multiplication was observed in the Advanced Markus chamber at voltages > 150 V. The exponential fitting successfully modeled this response and produced values agreeing with low voltage fits within 1.5%, while avoiding subjective voltage cutoff selection. Conclusion: The revised TRS‐398 provides accurate ion recombination corrections for monoenergetic PBS fields at low energies and low MU. However, accuracy of ion recombination correction decreases at higher energies and MU, particularly when the time structure was ambiguous or chamber dependent. Charge multiplication in small volume chambers presents an additional source of uncertainty not fully addressed by TRS‐398. Incorporating charge multiplication fitting methods may improve the robustness of reference dosimetry in synchrotron‐based PBS proton therapy.

  • Limitations of a fixed rise time model for beam delivery time prediction in dose-driven continuous scanning proton therapy

    by Kang Hao Lee, Clifford Ghee Ann Chua, Keith M. Furutani, Kah Seng Lew, Wei Yang Calvin Koh, Andrew Wibawa, Zubin Master, Masashi Yagi, James Cheow Lei Lee, Chris J. Beltran, et al.


  • Open Access

    Tumor control probability analysis in carbon-ion radiotherapy for prostate cancer considering the oxygen effect

    by Yushi Wakisaka, Shuka Fukuda, Toshiro Tsubouchi, Noriaki Hamatani, Masashi Yagi, Mayu Nakata, Yuki Tominaga, Kazuhiko Hayashi, Masaaki Takashina, Kazumasa Minami, et al.

  • Open Access

    Quantifying biological effects of spatially heterogeneous carbon ion dose distributions using EUD

    by Toshiro Tsubouchi, Misato Umemura, Kazumasa Minami, Naoto Saruwatari, Noriaki Hamatani, Masaaki Takashina, Masashi Yagi, Tatsuaki Kanai

    This study aimed to experimentally investigate the cell survival responses of tumor and normal cell lines to spatially heterogeneous carbon ion dose distributions with varying peak-to-valley dose ratios (PVDRs) and linear energy transfer (LET) conditions, and to assess the utility of equivalent uniform dose (EUD) as a quantitative metric for analyzing these responses. HSGc-C5 (tumor) and Nuli-1 (normal tissue) cell lines were irradiated using carbon ion beams with different spatial dose patterns (Grid, Frame, Half) and two PVDR levels under low LET conditions (~10 keV μm −1 ). Additionally, high LET (~50 keV μm −1 ) Spread Out Bragg Peak (SOBP) Grid patterns were used for the HSGc-C5 cells. Clonogenic survival assays were performed to evaluate biological response. Survival data were analyzed both as a function of delivered physical dose and EUD, calculated using an LQ model–based formulation. Tumor cells exhibited enhanced cytotoxic effects under high LET and high PVDR conditions (the dose required to reach SF = 0.1 was approximately 40% lower at PVDR = 4.0 and 10% lower at PVDR = 1.64 compared with the simulation results), whereas normal cells showed a slight sparing effect under low LET irradiation. Even at the same total dose and PVDR, different spatial dose patterns produced measurable differences in survival, underscoring the impact of spatial heterogeneity. EUD-based analysis further enabled quantitative comparison between heterogeneous and uniform dose distributions. These findings indicate that spatial dose heterogeneity and LET can be leveraged to enhance tumor control while reducing normal tissue damage in carbon ion therapy. The EUD approach may offer a practical tool for treatment plan evaluation in spatially modulated particle therapy.

  • Pioneering MCF MKM RBE-weighted dose calculation for carbon ion radiotherapy: development of a pencil beam algorithm and validation against Monte Carlo simulation on clinical CT data

    by Jun Tan, Alessio Parisi, Keith M Furutani, Masashi Yagi, Shannon Hartzell, Sridhar Yaddanapudi, Xiaoying Liang, Chunjoo Park, Chris J Beltran, Bo Lu

    Objective. This study aims to develop and validate a pencil beam (PB) algorithm for computing Mayo Clinic Florida microdosimetric kinetic model (MCF MKM)-based relative biological effectiveness (RBE) weighted doses in carbon-ion radiotherapy (CIRT), and to compare its accuracy and efficiency against Monte Carlo (MC) simulations using real patient computed tomography (CT) data. Approach. A PB algorithm was implemented to calculate both physical and microdosimetric parameters—using the abridged microdosimetry distribution methodology (AMDM)—for the MCF MKM model, and subsequently the RBE-weighted dose. Four clinical cases (brain, head and neck, lung and prostate) were planned in-house and computed using the PB algorithm and tool for particle simulation (TOPAS) MC simulations. Dose-volume histograms (DVHs), dose profiles, gamma analysis, and computational times were compared. Monochromatic and polychromatic AMDM kernels were also evaluated to assess any impact on RBE dose distributions. Main results. Except for the lung case, the PB algorithm showed strong agreement with TOPAS MC simulations, with gamma passing rates over 98% at 3%/3 mm and around 90% at 2%/2 mm for the other three cases. DVHs and dose profiles also closely matched. In the lung case, agreement was lower—87.6% at 3%/3 mm and 77.1% at 2%/2 mm—due to PB’s limitations in modeling Coulomb scattering in heterogeneous lung tissue. Still, PB calculations were completed in minutes, highlighting its potential for fast, clinically viable RBE dose evaluation. Significance. This study presents the first complete demonstration of an MCF MKM-based RBE dose calculation using a PB algorithm on actual patient CT data, providing a robust balance between accuracy and computational efficiency. Although limitations in PB modeling may introduce larger discrepancies in highly heterogeneous anatomical regions and sites, the overall performance and speed underscore the method’s viability for routine clinical CIRT planning.


  • Nuclear interaction correction based on dual-energy computed tomography in carbon-ion radiotherapy

    by Yushi Wakisaka, Masashi Yagi, Yuki Tominaga, Shinichi Shimizu, Teiji Nishio, Kazuhiko Ogawa

    Objective. Accurate dose predictions are crucial to maximizing the benefits of carbon-ion therapy (CIT). Carbon beams incident on the human body cause nuclear interactions with tissues, resulting in changes in the constituent nuclides and leading to dose errors that are conventionally corrected using conventional single-energy computed tomography (SECT). Dual-energy computed tomography (DECT) has frequently been used for stopping power estimation in particle therapy and is well suited for correcting nuclear reactions because of its detailed body-tissue elemental information. This study proposes a correction method for the absolute dose in CIT that considers changes in nuclide composition resulting from nuclear reactions with body tissues, as a novel application of DECT. Approach. The change in dose associated with nuclear reactions is determined by correcting each integrated depth dose component of the carbon beam using a nuclear interaction correction factor. This factor is determined based on the stopping power, mass density, and nuclear interaction cross-section in body tissue. The stopping power and mass density were calculated using established methods, whereas the nuclear interaction cross-section was newly defined through a conversion equation derived from the effective atomic number. Main results. Nuclear interaction correction factors and corrected doses were determined for 85 body tissues with known compositions, comparing them with existing SECT-based methods. The root-mean-square errors of the SECT- and DECT-based nuclear interaction correction factors relative to theoretical values were 0.66% and 0.39%, respectively. Significance. This indicates a notable enhancement in the estimation accuracy with DECT. The dose calculations in uniform body tissues derived from SECT showed slight over-correction in adipose and bone tissues, whereas those based on DECT were almost consistent with theoretical values. Our proposed method demonstrates the potential of DECT for enhancing dose calculation accuracy in CIT, complementing its established role in stopping power estimation.


  • Quantitative Assessment of Delivered Dose in Carbon Ion Spatially Fractionated Radiotherapy (C-SFRT) and Biological Response to C-SFRT

    by Toshiro Tsubouchi, Misato Umemura, Kazumasa Minami, Noriaki Hamatani, Naoto Saruwatari, Masaaki Takashina, Masashi Yagi, Keith M Furutani, Shinichi Shimizu, Tatsuaki Kanai

    Objective Applying carbon ion beams, which have high linear energy transfer and low scatter within the human body, to Spatially Fractionated Radiation Therapy (SFRT) could benefit the treatment of deep-seated or radioresistant tumors. This study aims to simulate the dose distributions of spatially fractionated beams (SFB) to accurately determine the delivered dose and model the cell survival rate following SFB irradiation. Approach Dose distributions of carbon ion beams are calculated using the Triple Gaussian Model. The sensitive volume of the detector used in measurements was also considered. If the measurements and simulations show good agreement, the dose distribution and absolute dose delivered by SFB can be accurately estimated. Three types of dose distributions were delivered to human salivary gland cells (HSGc-C5): uniform dose distribution (UDD), and one-dimensional (1D) grid-like dose distributions (GDD) with 6 mm and 8 mm spacing. These provided high (Peak-to-Valley Dose Ratio, PVDR=4.0) and low (PVDR=1.64) dose differences between peak and valley doses, respectively. Linear-Quadratic (LQ) model parameters for HSGc-C5 were derived from the UDD and cell survival fractions (SF) were simulated for 1D GDD using these values. Main results Good agreement was observed between measurements and simulations when accounting for detector volume. However, the TPS results overestimated dose in steep gradient region, likely due to the 2.0 mm calculation grid size. LQ parameters for HSGc-C5 were α = 0.34 and β = 0.057. The 1D GDD with 6 mm spacing showed good agreement between simulations and experiments, but the 8.0 mm spacing resulted in lower experimental cell survival. Significance We successfully simulated grid-like dose distributions and conducted SF simulations. The results suggest potential cell-killing effects due to high-dose differences in SFB.