A rapid on-site loop-mediated isothermal amplification technology as an early warning system for the detection of Shiga toxin-producing Escherichia coli in water
Open Access
- 7 August 2024
- journal article
- research article
- Published by Microbiology Society in Microbiology
- Vol. 170 (8) , 001485
Abstract
Shiga toxin-producing Escherichia coli (STEC) is an important waterborne pathogen capable of causing serious gastrointestinal infections with potentially fatal complications, including haemolytic–uremic syndrome. All STEC serogroups harbour genes that encode at least one Shiga toxin (stx1 and/or stx2), which constitute the primary virulence factors of STEC. Loop-mediated isothermal amplification (LAMP) enables rapid real-time pathogen detection with a high degree of specificity and sensitivity. The aim of this study was to develop and validate an on-site portable diagnostics workstation employing LAMP technology to permit rapid real-time STEC detection in environmental water samples. Water samples (n=28) were collected from groundwater wells (n=13), rivers (n=12), a turlough (n=2) and an agricultural drain (n=1) from the Corrib catchment in Galway. Water samples (100 ml) were passed through a 0.22 µm filter, and buffer was added to elute captured cells. Following filtration, eluates were tested directly using LAMP assays targeting stx1, stx2 and E. coli phoA genes. The portable diagnostics workstation was used in field studies to demonstrate the on-site testing capabilities of the instrument. Real-time PCR assays targeting stx1 and stx2 genes were used to confirm the results. The limit of detection for stx1, stx2 and phoA LAMP assays were 2, 2 and 6 copies, respectively. Overall, stx1, stx2 and phoA genes were detected by LAMP in 15/28 (53.6 %), 9/28 (32.2 %) and 24/28 (85.7 %) samples, respectively. For confirmation, the LAMP results for stx1 and stx2 correlated perfectly (100 %) with those obtained using PCR. The portable diagnostics workstation exhibited high sensitivity throughout the on-site operation, and the average time from sample collection to final result was 40 min. We describe a simple, transferable and efficient diagnostic technology for on-site molecular analysis of various water sources. This method allows on-site testing of drinking water, enabling evidence-based decision-making by public health and water management authorities.Keywords
Funding Information
- Environmental Protection Agency (2021-HE-1033)
This publication has 36 references indexed in Scilit:
- Spatiotemporal dynamics of Escherichia coli presence and magnitude across a national groundwater monitoring network, Republic of Ireland, 2011–2020Science of The Total Environment, 2022
- Contamination of domestic groundwater systems by verotoxigenic escherichia coli (VTEC), 2003–2019: A global scoping reviewWater Research, 2021
- Cryptosporidium spp. in groundwater supplies intended for human consumption – A descriptive review of global prevalence, risk factors and knowledge gapsWater Research, 2020
- Rapid and in-situ detection of fecal indicator bacteria in water using simple DNA extraction and portable loop-mediated isothermal amplification (LAMP) PCR methodsWater Research, 2019
- Shiga toxigenic Escherichia coli incidence is related to small area variation in cattle density in a region in IrelandScience of The Total Environment, 2018
- A loop-mediated isothermal amplification (LAMP) assay for the rapid detection of Enterococcus spp. in waterWater Research, 2017
- Loop‐Mediated Isothermal Amplification for Detection of Nucleic AcidsCurrent Protocols in Molecular Biology, 2014
- Development and application of a loop-mediated isothermal amplification method on rapid detection Escherichia coli O157 strains from food samplesMolecular Biology Reports, 2009
- Loop-mediated isothermal amplification (LAMP): a rapid, accurate, and cost-effective diagnostic method for infectious diseasesJournal of Infection and Chemotherapy, 2009
- Detection by 5′-nuclease PCR of Shiga-toxin producing Escherichia coli O26, O55, O91, O103, O111, O113, O145 and O157:H7, associated with the world's most frequent clinical casesMolecular and Cellular Probes, 2004