Chemometric Correction of Drift Effects in Optical Spectra
- 1 June 2004
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 58 (6) , 683-692
Abstract
All quantitative data evaluation techniques applied to spectroscopy are based on the assumption that the baseline is stable in time. If this prerequisite is violated, major concentration errors can result since drifts are evaluated along with true spectroscopic features. For handling baseline drifts two improved principal component regression (PCR) methods are presented and compared to conventional Savitzky–Golay preprocessing followed by conventional PCR. The proposed drift-correction methods take advantage of baseline drifts being rather broad compared to the absorption features. The only assumption made is that drift effects can be modeled sufficiently by polynomials of user-selectable order. One correction method modifies principal components such that drifts of polynomial shape are orthogonal to the calibration model and thus cannot influence the concentration result. The second method extends the calibration model by synthetic so-called pseudo-principal components. While the principal components model the true spectral features, the pseudo-principal components describe drifts simultaneously and independently. Hence, drifts are explicitly included into the calibration and cannot cause erroneous concentration results. It is demonstrated that both correction methods are equivalently as powerful as the conventional PCR in the absence of drifts and superior if drifts are present. The overall performance—in the absence and presence of baseline drifts—of the novel methods makes them more versatile and reliable than the conventional Savitzky–Golay data preprocessing. In almost all investigated cases, the average concentration errors were significantly smaller than those obtained by Savitzky– Golay preprocessing. Furthermore, polyPCR and pPCR do not need laborious optimizations as Savitzky–Golay does for preventing suppression of relevant signal components. polyPCR demands less computation expense than Savitzky–Golay, and pPCR extracts the drift spectrum as additional qualitative information not provided by Savitzky–Golay.Keywords
This publication has 16 references indexed in Scilit:
- Peer Reviewed: Mid-IR Fiber-Optic Sensors2003
- Derivative Preprocessing and Optimal Corrections for Baseline Drift in Multivariate CalibrationApplied Spectroscopy, 2000
- Correction of background drifts in optical spectra by means of “pseudo principal components”Chemometrics and Intelligent Laboratory Systems, 2000
- Synthetic Multivariate Models to Accommodate Unmodeled Interfering Spectral Components during Quantitative Spectral AnalysesApplied Spectroscopy, 2000
- Mid-infrared evanescent wave sensors - a novel approach for subsea monitoringMeasurement Science and Technology, 1999
- Optical UV Derivative Spectroscopy for Monitoring Gaseous EmissionsApplied Spectroscopy, 1999
- Measurement of Carboxyhemoglobin in Forensic Blood Samples Using UV-Visible Spectrometry and Improved Principal Component RegressionApplied Spectroscopy, 1999
- Calibration modeling by partial least-squares and principal component regression and its optimization using an improved leverage correction for prediction testingChemometrics and Intelligent Laboratory Systems, 1990
- Smoothing and differentiation of data by simplified least square procedureAnalytical Chemistry, 1972
- Smoothing and Differentiation of Data by Simplified Least Squares Procedures.Analytical Chemistry, 1964