Frank Vogt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Frank Vogt has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Karl Booksh
Department of Chemistry and Biochemistry, Arizona State University, Tempe, AZ 85287, USA
2 shared publications- Boris Mizaikoff
Institute of Analytical and Bioanalytical Chemistry Ulm University Ulm Germany
1 shared publication Hannes Steiner
Arizona State University, Department of Chemistry and Biochemistry, Mail stop 1604, Tempe, Arizona 85287 (F.V., K.B.); Vienna University of Technology, Institute for Chemical Technology and Analytics, Getreidemarkt 9/164, A-1060 Vienna, Austria (H.S.); and Georgia Institute of Technology, School of Chemistry and Biochemistry, Atlanta, Georgia 30332-0400 (B.M.)
1 shared publicationSoame Banerji
Department of Chemistry and Biochemistry, Arizona State University, Tempe, AZ 85287, USA
1 shared publication
Latest Publications
- 1 July 2004
- Published by Wiley in Journal of Chemometrics
- Vol. 18 (7-8) , 350-362
Utilizing three‐dimensional wavelet transforms for accelerated evaluation of hyperspectral image cubes
Hyperspectral imaging sensors are continuously enhanced by increasing spatial and spectral resolution. However, the ‘curse of dimensionality’ comes into effect, as the amount of acquired data increases in third order (two spatial, one spectral dimension). On top of that, the computational expense of many chemometric data evaluation techniques such as principal component analysis (PCA) rises also in third order with the data amount. Thus the need for computer memory is increased in third and the demand for computational power up to ninth order. One immediate consequence of massively increased computation times is a decreased time resolution of hyperspectral imagers, which is especially detrimental in online applications. Archiving humongous amounts of data becomes another burden. Thus it is anticipated that increased computation resources alone will not be able to facilitate fast online evaluation of hyperspectral data cubes or even to handle the acquired data. In this study, 3D wavelet transforms are used for compression of hyperspectral data cubes prior to chemometric data evaluation and/or data storage. Five different wavelet types of the Daubechies family are compared with respect to their ability to preserve relevant information in compressed data cubes. Because only relevant information has to be considered, shorter computation time and less storage space are required. By means of experimental hyperspectral data cubes it is demonstrated that additional computation expense for the 3D wavelet transform is largely overcompensated by reduced calculations necessitated by smaller data cubes. In the presented examples, computation time for a PCA could be decreased by one order of magnitude; storage space could be reduced to <1% of the original size. It was found that the wavelet type has a major influence on the acceleration factors. Copyright © 2005 John Wiley & Sons, Ltd.
- 1 July 2004
- Published by Wiley in Journal of Chemometrics
- Vol. 18 (7-8) , 350-362
Utilizing three‐dimensional wavelet transforms for accelerated evaluation of hyperspectral image cubes
Hyperspectral imaging sensors are continuously enhanced by increasing spatial and spectral resolution. However, the ‘curse of dimensionality’ comes into effect, as the amount of acquired data increases in third order (two spatial, one spectral dimension). On top of that, the computational expense of many chemometric data evaluation techniques such as principal component analysis (PCA) rises also in third order with the data amount. Thus the need for computer memory is increased in third and the demand for computational power up to ninth order. One immediate consequence of massively increased computation times is a decreased time resolution of hyperspectral imagers, which is especially detrimental in online applications. Archiving humongous amounts of data becomes another burden. Thus it is anticipated that increased computation resources alone will not be able to facilitate fast online evaluation of hyperspectral data cubes or even to handle the acquired data. In this study, 3D wavelet transforms are used for compression of hyperspectral data cubes prior to chemometric data evaluation and/or data storage. Five different wavelet types of the Daubechies family are compared with respect to their ability to preserve relevant information in compressed data cubes. Because only relevant information has to be considered, shorter computation time and less storage space are required. By means of experimental hyperspectral data cubes it is demonstrated that additional computation expense for the 3D wavelet transform is largely overcompensated by reduced calculations necessitated by smaller data cubes. In the presented examples, computation time for a PCA could be decreased by one order of magnitude; storage space could be reduced to <1% of the original size. It was found that the wavelet type has a major influence on the acceleration factors. Copyright © 2005 John Wiley & Sons, Ltd.
- 1 June 2004
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 58 (6) , 683-692
Chemometric Correction of Drift Effects in Optical Spectra
All quantitative data evaluation techniques applied to spectroscopy are based on the assumption that the baseline is stable in time. If this prerequisite is violated, major concentration errors can result since drifts are evaluated along with true spectroscopic features. For handling baseline drifts two improved principal component regression (PCR) methods are presented and compared to conventional Savitzky–Golay preprocessing followed by conventional PCR. The proposed drift-correction methods take advantage of baseline drifts being rather broad compared to the absorption features. The only assumption made is that drift effects can be modeled sufficiently by polynomials of user-selectable order. One correction method modifies principal components such that drifts of polynomial shape are orthogonal to the calibration model and thus cannot influence the concentration result. The second method extends the calibration model by synthetic so-called pseudo-principal components. While the principal components model the true spectral features, the pseudo-principal components describe drifts simultaneously and independently. Hence, drifts are explicitly included into the calibration and cannot cause erroneous concentration results. It is demonstrated that both correction methods are equivalently as powerful as the conventional PCR in the absence of drifts and superior if drifts are present. The overall performance—in the absence and presence of baseline drifts—of the novel methods makes them more versatile and reliable than the conventional Savitzky–Golay data preprocessing. In almost all investigated cases, the average concentration errors were significantly smaller than those obtained by Savitzky– Golay preprocessing. Furthermore, polyPCR and pPCR do not need laborious optimizations as Savitzky–Golay does for preventing suppression of relevant signal components. polyPCR demands less computation expense than Savitzky–Golay, and pPCR extracts the drift spectrum as additional qualitative information not provided by Savitzky–Golay.
- 1 June 2004
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 58 (6) , 683-692
Chemometric Correction of Drift Effects in Optical Spectra
All quantitative data evaluation techniques applied to spectroscopy are based on the assumption that the baseline is stable in time. If this prerequisite is violated, major concentration errors can result since drifts are evaluated along with true spectroscopic features. For handling baseline drifts two improved principal component regression (PCR) methods are presented and compared to conventional Savitzky–Golay preprocessing followed by conventional PCR. The proposed drift-correction methods take advantage of baseline drifts being rather broad compared to the absorption features. The only assumption made is that drift effects can be modeled sufficiently by polynomials of user-selectable order. One correction method modifies principal components such that drifts of polynomial shape are orthogonal to the calibration model and thus cannot influence the concentration result. The second method extends the calibration model by synthetic so-called pseudo-principal components. While the principal components model the true spectral features, the pseudo-principal components describe drifts simultaneously and independently. Hence, drifts are explicitly included into the calibration and cannot cause erroneous concentration results. It is demonstrated that both correction methods are equivalently as powerful as the conventional PCR in the absence of drifts and superior if drifts are present. The overall performance—in the absence and presence of baseline drifts—of the novel methods makes them more versatile and reliable than the conventional Savitzky–Golay data preprocessing. In almost all investigated cases, the average concentration errors were significantly smaller than those obtained by Savitzky– Golay preprocessing. Furthermore, polyPCR and pPCR do not need laborious optimizations as Savitzky–Golay does for preventing suppression of relevant signal components. polyPCR demands less computation expense than Savitzky–Golay, and pPCR extracts the drift spectrum as additional qualitative information not provided by Savitzky–Golay.